文献速递类风湿关节炎

早期类风湿关节炎中全自动关节间隙宽度测量与数字X线放射测量法研究

Fully automated joint space width measurement and digital X-ray radiogrammetry in early RA.
PubMed 文献 · RMD Open · 2017-06-29

该研究基于SWEdish FarmacOTherapy研究中96例早期类风湿关节炎(eRA)患者的576个关节,比较全自动数字关节间隙宽度(JSW)测量与改良Sharp van der Heijde评分(SHS)中关节间隙狭窄(JSN)评分的关联。结果显示,基线至1年JSW和骨密度(BMD)均显著下降,ΔJSW与ΔBMD呈显著正相关;未损伤关节(JSN=0)的JSW显著宽于损伤关节(JSN>0)。全自动JSW测量可能作为快速、观察者独立的工具用于评估eRA软骨损伤。

要点

  • 基线至1年JSW从1.69±0.19 mm降至1.66±0.19 mm(p<0.01),BMD从0.583±0.068 g/cm2降至0.566±0.074 g/cm2(p<0.01)。
  • ΔJSW与ΔBMD在1年内呈显著正相关(p<0.0001)。
  • 未损伤关节(JSN=0)JSW显著宽于损伤关节(JSN>0),调整模型差异仍显著(p=0.042)。

核心结论

  • 全自动数字JSW测量可能作为快速、观察者独立的工具用于评估eRA软骨损伤。

研究设计与样本

  • 基于SWEdish FarmacOTherapy研究,纳入96例eRA患者,对576个关节进行全自动双侧第2、3、4掌骨JSW测量,并与SHS的JSN评分比较,采用多水平混合模型统计。

主要发现

  • 基线至1年JSW从1.69±0.19 mm降至1.66±0.19 mm(p<0.01),BMD从0.583±0.068 g/cm2降至0.566±0.074 g/cm2(p<0.01)。
  • ΔJSW与ΔBMD在1年内呈显著正相关(p<0.0001)。
  • 个体关节水平,未损伤关节(JSN=0)JSW为1.68 mm(95% CI 1.70 to 1.67),损伤关节(JSN>0)为1.54 mm(95% CI 1.63 to 1.46)。
  • 未调整多水平模型显示未损伤关节JSW 1.68 mm(95% CI 1.72 to 1.64)与损伤关节1.63 mm(95% CI 1.68 to 1.58)差异显著(p=0.0048)。
  • 调整模型显示未损伤关节JSW 1.66 mm(95% CI 1.70 to 1.61)与损伤关节1.62 mm(95% CI 1.68 to 1.56)差异仍显著(p=0.042)。

临床怎么用

  • 全自动JSW测量可作为观察者独立的快速工具,辅助评估eRA患者的软骨损伤。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To study fully automated digital joint space width (JSW) and bone mineral density (BMD) in relation to a conventional radiographic scoring method in early rheumatoid arthritis (eRA). METHODS: Radiographs scored by the modified Sharp van der Heijde score (SHS) in patients with eRA were acquired from the SWEdish FarmacOTherapy study. Fully automated JSW measurements of bilateral metacarpals 2, 3 and 4 were compared with the joint space narrowing (JSN) score in SHS. Multilevel mixed model statistics were applied to calculate the significance of the association between ΔJSW and ΔBMD over 1 year, and the JSW differences between damaged and undamaged joints as evaluated by the JSN. RESULTS: Based on 576 joints of 96 patients with eRA, a significant reduction from baseline to 1 year was observed in the JSW from 1.69 (±0.19) mm to 1.66 (±0.19) mm (p<0.01), and BMD from 0.583 (±0.068) g/cm2 to 0.566 (±0.074) g/cm2 (p<0.01). A significant positive association was observed between ΔJSW and ΔBMD over 1 year (p<0.0001). On an individual joint level, JSWs of undamaged (JSN=0) joints were wider than damaged (JSN>0) joints: 1.68 mm (95% CI 1.70 to 1.67) vs 1.54 mm (95% CI 1.63 to 1.46). Similarly the unadjusted multilevel model showed significant differences in JSW between undamaged (1.68 mm (95% CI 1.72 to 1.64)) and damaged joints (1.63 mm (95% CI 1.68 to 1.58)) (p=0.0048). This difference remained significant in the adjusted model: 1.66 mm (95% CI 1.70 to 1.61) vs 1.62 mm (95% CI 1.68 to 1.56) (p=0.042). CONCLUSIONS: To measure the JSW with this fully automated digital tool may be useful as a quick and observer-independent application for evaluating cartilage damage in eRA. TRIAL REGISTRATION NUMBER: NCT00764725.

来源:RMD Open,查看原文。版权归原作者所有。

引用

  1. Platten M, Kisten Y, Kälvesten J, et al. Fully automated joint space width measurement and digital X-ray radiogrammetry in early RA. RMD Open. 2017. PMID: 28879043. doi:10.1136/rmdopen-2016-000369