类风湿关节炎超声滑膜炎评分:EULAR-OMERACT 超声工作组第一部分:标准化共识评分系统的定义与开发
该研究采用多步骤迭代方法,基于静态图像和患者扫描评估不同超声医师对类风湿关节炎滑膜炎定义和评分的一致性,并通过 Delphi 流程达成共识。结果建立了结合灰阶滑膜肥厚与能量多普勒信号的标准化超声滑膜炎定义和半定量评分系统。
要点
- 基线可靠性变异大,静态图像评分优于动态直接采集评分。
- 静态图像下 PD 评分组内和组间可靠性优秀,GS 变异较大。
- 基于患者扫描的可靠性未达 0.50,需进一步评估性能。
核心结论
- 多步骤共识流程产出了类风湿关节炎滑膜炎的标准化超声定义和量化系统,包括滑膜肥厚和能量多普勒的联合与单独成分。
研究设计与样本
- 采用多步骤迭代方法,包括基于静态图像和患者扫描的基线一致性评估,以及 Delphi 流程获取共识定义。
主要发现
- 基线可靠性高度可变,静态图像评分可靠性优于动态直接采集评分。
- 静态图像下 PD 评分二分类和半定量分级的组内与组间可靠性优秀,GS 评分变异较大(κ 范围分别为 -0.05 至 1 和 0.59 至 0.92)。
- 基于患者扫描的组内和组间可靠性可变,任何成分的平均 κ 系数均未达到 0.50。
关键数值与推荐
- 共识定义纳入低回声滑膜肥厚和 PD 信号同时存在,并开发了基于 PD 量和滑膜肥厚体积与外观的半定量严重程度评分。
临床怎么用
- 该标准化超声定义和评分系统可用于类风湿关节炎滑膜炎的评估,但需进一步评估性能后方可用于临床试验。
局限性
- 基于患者扫描的可靠性未达 0.50,需进一步评估该系统的性能。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: To develop a consensus-based ultrasound (US) definition and quantification system for synovitis in rheumatoid arthritis (RA). METHODS: A multistep, iterative approach was used to: (1) evaluate the baseline agreement on defining and scoring synovitis according to the usual practice of different sonographers, using both grey-scale (GS) (synovial hypertrophy (SH) and effusion) and power Doppler (PD), by reading static images and scanning patients with RA and (2) evaluate the influence of both the definition and acquisition technique on reliability followed by a Delphi exercise to obtain consensus definitions for synovitis, elementary components and scoring system. RESULTS: Baseline reliability was highly variable but better for static than dynamic images that were directly acquired and immediately scored. Using static images, intrareader and inter-reader reliability for scoring PD were excellent for both binary and semiquantitative (SQ) grading but GS showed greater variability for both scoring systems (κ ranges: -0.05 to 1 and 0.59 to 0.92, respectively). In patient-based exercise, both intraobserver and interobserver reliability were variable and the mean κ coefficients did not reach 0.50 for any of the components. The second step resulted in refinement of the preliminary Outcome Measures in Rheumatology synovitis definition by including the presence of both hypoechoic SH and PD signal and the development of a SQ severity score, depending on both the amount of PD and the volume and appearance of SH. CONCLUSION: A multistep consensus-based process has produced a standardised US definition and quantification system for RA synovitis including combined and individual SH and PD components. Further evaluation is required to understand its performance before application in clinical trials.
引用
- D'Agostino MA, Terslev L, Aegerter P, et al. Scoring ultrasound synovitis in rheumatoid arthritis: a EULAR-OMERACT ultrasound taskforce-Part 1: definition and development of a standardised, consensus-based scoring system. RMD Open. 2017. PMID: 28948983. doi:10.1136/rmdopen-2016-000428
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。