高分辨率测压与UCLA SCTC GIT 2.0在系统性硬化症中的比较
研究40例系统性硬化症(SSc)患者,评估食管高分辨率测压(HRM)结果与UCLA SCTC GIT 2.0问卷评分的相关性。结果显示远端食管收缩幅度和LES静息压与反流及总体胃肠道症状评分呈负相关,GIT 2.0可作为提示需进一步食管测压的指标。
要点
- SSc患者远端食管收缩幅度和LES静息压显著低于健康对照。
- 远端食管收缩幅度与反流评分(r=-0.64)和总GIT评分(r=-0.54)负相关。
- GIT 2.0问卷简便易用,可提示需进一步行食管测压检查。
核心结论
- SSc患者食管蠕动减弱或无蠕动与UCLA SCTC GIT 2.0反流及总体胃肠道症状评分升高相关。
- GIT 2.0问卷可作为提示需进一步胃肠道检查(包括食管测压)的指标。
研究设计与样本
- 研究纳入40例SSc患者,均填写UCLA SCTC GIT 2.0问卷并接受高分辨率测压(HRM,Solar GI MMS)。
- HRM数据与15名健康志愿者进行比较。
主要发现
- SSc患者平均年龄46±7岁,病程9.3±7年;上消化道症状报告率85.7%,下消化道症状75%,5%无症状。
- UCLA SCTC GIT 2.0各项平均分:反流1.2±0.8,腹胀1.6±1.2,粪便污渍0.3±0.9,腹泻0.8±1,社会1±1,情感1±1.1,便秘0.5±0.9,总GIT评分0.9±0.6。
- SSc患者LES压力和远端食管收缩幅度显著低于对照组;主要测压发现为LES静息压降低(40%)和无蠕动(40%)。
- 远端食管收缩幅度与反流评分负相关(r=-0.64,p=0.001),与总GIT评分负相关(r=-0.54,p=0.007)。
- LES静息压与反流评分负相关(r=-0.46,p=0.019),与总GIT评分负相关(r=-0.42,p=0.03),与腹泻评分负相关(r=-0.062,p=0.002)。
临床怎么用
- 对SSc患者可采用UCLA SCTC GIT 2.0问卷评估胃肠道症状,评分较高者提示需进一步行食管HRM检查。
- HRM发现远端食管收缩幅度降低或LES静息压降低时,应关注反流及总体胃肠道症状的管理。
局限性
- 样本量较小(40例SSc患者和15名对照),可能影响结果的普遍性。
- 原文未报告研究设计类型(如横断面或队列)及随访信息。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: To study esophageal high resolution manometry (HRM) in systemic sclerosis (SSc) patients and the correlation of findings to The University of California, Los Angeles Scleroderma Clinical Trials Consortium gastrointestinal tract 2.0 (UCLA SCTC_GIT 2.0). METHODS: Forty SSc patients were administered to the UCLA SCTC GIT 2.0. Patients underwent HRM study (Solar GI MMS). HRM data were compared with 15 healthy volunteers. RESULTS: Forty patients with mean age 46 ± 7 years and disease duration 9.3 ± 7 years reported upper (85.7%), lower GI symptoms (75%), while 5% reported no symptoms. Mean ± SD scores of UCLA SCTC_GIT 2.0 items were as follows: reflux 1.2 ± 0.8, distention 1.6 ± 1.2, fecal soiling 0.3 ± 0.9, diarrhea 0.8 ± 1, social 1 ± 1, emotional 1 ± 1.1, constipation 0.5 ± 0.9, and total GIT score 0.9 ± 0.6. Lower esophageal sphincter (LES) pressure and distal esophageal amplitude were significantly lower in SSc patients than controls. Main manometric findings were decreased LES resting pressure (40%) and aperistalsis (40%). Regression analyses showed distal esophageal amplitude and LES resting pressure negatively correlated with reflux score (r = -0.64; p = 0.001 and r = -0.46; p = 0.019, respectively), and total GIT score (r = -0.54; p = 0.007 and r = -0.42; p = 0.03, respectively). LES resting pressure had negative correlations with diarrhea score (r = -0.062; p = 0.002). CONCLUSIONS: Decreased distal esophageal amplitude encountered as hypoperistalsis or even aperistalsis was associated with increased reflux and GIT scores (negatively correlated) UCLA SCTC_GIT 2.0 questionnaires. The GIT2.0 is easy to use and can serve as an indicator that further testing of the GI tract, including the esophagus, is indicated.
引用
- Abozaid HSM, Imam HMK, Abdelaziz MM, et al. High-resolution manometry compared with the University of California, Los Angeles Scleroderma Clinical Trials Consortium GIT 2.0 in Systemic Sclerosis. Semin Arthritis Rheum. 2017. PMID: 28624173. doi:10.1016/j.semarthrit.2017.05.005
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。