计算机辅助平面测量法评估系统性硬化相关指端溃疡面积的可靠性
本研究纳入36例系统性硬化谱系病患者的107个指端溃疡,比较照片上椭圆与自由手绘两种计算机辅助平面测量法的可靠性。校准的组内相关系数为0.99;椭圆法组内与组间信度分别为0.97和0.77,自由手绘法分别为0.98和0.76。提示该方法用于测量指端溃疡面积具有极高可靠性,但尚需进一步推动其作为临床试验和临床结局指标。
要点
- 计算机辅助平面测量法测量系统性硬化指端溃疡面积可靠性极高。
- 校准的组内信度为0.99,两种面积测量法组内信度均≥0.97。
- 两种方法组间信度均为0.76–0.77,低于组内信度。
核心结论
- 计算机辅助平面测量法应用于系统性硬化相关指端溃疡可具有极高可靠性。
- 尚需进一步工作推动该方法作为临床试验和临床实践的结局测量工具。
研究设计与样本
- 对36例系统性硬化谱系病患者共107个指端溃疡拍摄照片。
- 由3名评估者使用定制软件校准照片尺寸并绘制椭圆或自由手绘感兴趣区(ROI)。
- 保存ROI形状与尺寸用于后续分析,比较两种面积测量方法并评估校准与测量信度。
主要发现
- 单名评估者对每张图像重复5次校准的组内相关系数(评估者内信度)为0.99。
- 椭圆ROI与自由手绘ROI测量的溃疡平均面积分别为18.7±20.2 mm²和17.6±19.3 mm²。
- 椭圆ROI的评估者内与评估者间信度分别为0.97和0.77。
- 自由手绘ROI的评估者内与评估者间信度分别为0.98和0.76。
临床怎么用
- 临床与研究场景中可采用计算机辅助平面测量法对系统性硬化指端溃疡面积进行客观可靠评估。
- 椭圆与自由手绘ROI两种方法评估者内信度均很高,但评估者间信度中等,需注意多评估者间的标准化。
局限性
- 研究仅评估照片平面测量法的信度,未涉及该方法作为结局指标的纵向验证。
- 研究纳入系统性硬化谱系病患者,结论外推需谨慎。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Digital ulcers are a major problem in patients with systemic sclerosis (SSc), causing severe pain and impairment of hand function. In addition, digital ulcers heal slowly and sometimes become infected, which can lead to gangrene and necessitate amputation if appropriate intervention is not taken. A reliable, objective method for assessing digital ulcer healing or progression is needed in both the clinical and research arenas. This study was undertaken to compare 2 computer-assisted planimetry methods of measurement of digital ulcer area on photographs (ellipse and freehand regions of interest [ROIs]), and to assess the reliability of photographic calibration and the 2 methods of area measurement. METHODS: Photographs were taken of 107 digital ulcers in 36 patients with SSc spectrum disease. Three raters assessed the photographs. Custom software allowed raters to calibrate photograph dimensions and draw ellipse or freehand ROIs. The shapes and dimensions of the ROIs were saved for further analysis. RESULTS: Calibration (by a single rater performing 5 repeats per image) produced an intraclass correlation coefficient (intrarater reliability) of 0.99. The mean ± SD areas of digital ulcers assessed using ellipse and freehand ROIs were 18.7 ± 20.2 mm2 and 17.6 ± 19.3 mm2 , respectively. Intrarater and interrater reliability of the ellipse ROI were 0.97 and 0.77, respectively. For the freehand ROI, the intrarater and interrater reliability were 0.98 and 0.76, respectively. CONCLUSION: Our findings indicate that computer-assisted planimetry methods applied to SSc-related digital ulcers can be extremely reliable. Further work is needed to move toward applying these methods as outcome measures for clinical trials and in clinical settings.
引用
- Simpson V, Hughes M, Wilkinson J, et al. Quantifying Digital Ulcers in Systemic Sclerosis: Reliability of Computer-Assisted Planimetry in Measuring Lesion Size. Arthritis Care Res (Hoboken). 2018. PMID: 28575546. doi:10.1002/acr.23300
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。