PubMed 文献 · Ann Rheum Dis · 2017-06-21

该跨国随机双盲平行组研究纳入312例对TNFi应答不足或不耐受的活动性RA患者,比较GP2013与EU/US参照利妥昔单抗联合MTX的药代动力学和药效学等效性。结果显示所有比较的AUC几何均值比90%CI均在80%–125%等效限内,B细胞清除等效,疗效、安全性和免疫原性相似。

要点

  • GP2013与RTX-EU、RTX-US的AUC几何均值比90%CI均落在80%–125%等效限内。
  • 三方药效学等效性通过B细胞清除得到证实。
  • GP2013与参照利妥昔单抗的疗效、安全性和免疫原性相似。

核心结论

  • GP2013、RTX-EU和RTX-US三方药代动力学/药效学等效性得到证实。
  • GP2013与参照利妥昔单抗的疗效、安全性和免疫原性特征相似。

研究设计与样本

  • 跨国、随机、双盲、平行组研究,纳入312例对TNFi治疗应答不足或不耐受的活动性RA患者。
  • 患者随机接受GP2013或EU参照利妥昔单抗(RTX-EU)或US参照利妥昔单抗(RTX-US),联合甲氨蝶呤和叶酸。
  • 主要终点为血清浓度-时间曲线下面积(AUC0-inf),并评估至第24周的药代动力学、药效学、疗效、免疫原性和安全性。

主要发现

  • GP2013 vs RTX-EU的AUC几何均值比为1.106(90%CI 1.010–1.210)。
  • GP2013 vs RTX-US的AUC几何均值比为1.012(90%CI 0.925–1.108)。
  • RTX-EU vs RTX-US的AUC几何均值比为1.093(90%CI 0.989–1.208)。
  • 三方药效学等效性通过B细胞清除得到证实。
  • GP2013与RTX的疗效、安全性和免疫原性特征相似。

关键数值与推荐

  • 生物等效性限值为AUC几何均值比90%CI落在80%至125%之间。
  • 所有三方比较的90%CI均在该等效限内。

临床怎么用

  • GP2013可作为参照利妥昔单抗的生物类似药,联合甲氨蝶呤用于对TNFi应答不足或不耐受的活动性RA患者。
  • 临床使用时需关注其与参照利妥昔单抗相似的疗效、安全性和免疫原性特征。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: The aim of this report is to demonstrate pharmacokinetic (PK) and pharmacodynamic (PD) equivalence as well as similar efficacy, safety and immunogenicity between GP2013, a biosimilar rituximab, and innovator rituximab (RTX) in patients with rheumatoid arthritis (RA) with inadequate response or intolerance to tumour necrosis factor inhibitor (TNFi) treatment. METHODS: In this multinational, randomised, double-blind, parallel-group study, 312 patients with active disease despite prior TNFi therapy were randomised to receive GP2013 or either the EU (RTX-EU) or the US (RTX-US) reference product, along with methotrexate (MTX) and folic acid. The primary endpoint was the area under the serum concentration-time curve from study drug infusion to infinity (AUC0-inf). Additional PK and PD parameters, along with efficacy, immunogenicity and safety outcomes were also assessed up to week 24. RESULTS: The 90% CI of the geometric mean ratio of the AUCs were within the bioequivalence limits of 80% to 125% for all three comparisons; GP2013 versus RTX-EU: 1.106 (90% CI 1.010 to 1.210); GP2013 versus RTX-US: 1.012 (90% CI 0.925 to 1.108); and RTX-EU versus RTX-US: 1.093 (90% CI 0.989 to 1.208). Three-way PD equivalence of B cell depletion was also demonstrated. Efficacy, safety and immunogenicity profiles were similar between GP2013 and RTX. CONCLUSIONS: Three-way PK/PD equivalence of GP2013, RTX-EU and RTX-US was demonstrated. Efficacy, safety and immunogenicity profiles were similar between GP2013 and RTX. TRIAL REGISTRATION NUMBER: NCT01274182; Results.

来源:Ann Rheum Dis,查看原文。版权归原作者所有。

引用

  1. Smolen JS, Cohen SB, Tony HP, et al. A randomised, double-blind trial to demonstrate bioequivalence of GP2013 and reference rituximab combined with methotrexate in patients with active rheumatoid arthritis. Ann Rheum Dis. 2017. PMID: 28637670. doi:10.1136/annrheumdis-2017-211281

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。