双能CT在痛风患者中的诊断准确性:一项荟萃分析
该荟萃分析纳入8项研究、510例痛风患者和268例非痛风炎性关节炎对照,评估双能CT(DECT)的诊断效能。汇总敏感度为84.7%(95%CI 81.3-87.7),特异度为93.7%(95%CI 93.0-96.3),AUC为0.956,提示DECT对痛风具有高诊断准确性。
要点
- DECT诊断痛风的汇总敏感度为84.7%,特异度为93.7%。
- DECT的AUC为0.956,Q*指数为0.889,提示诊断准确性高。
- 样本量、研究设计和诊断标准不是异质性来源,亚组分析未改变整体诊断准确性。
核心结论
- DECT对痛风具有高诊断准确性,在痛风诊断中起重要作用。
研究设计与样本
- 检索Medline、Embase和Cochrane Library数据库,对DECT诊断痛风准确性的研究进行荟萃分析。
- 共纳入8项研究,包括510例痛风患者和268例对照(非痛风炎性关节炎患者)。
主要发现
- DECT汇总敏感度为84.7%(95%CI 81.3-87.7),汇总特异度为93.7%(95%CI 93.0-96.3)。
- 阳性似然比为9.882(95%CI 6.122-15.95),阴性似然比为0.163(95%CI 0.097-0.272),诊断比值比为78.10(95%CI 31.14-195.84)。
- DECT的AUC为0.956,Q*指数为0.889,提示诊断准确性高。
- 荟萃分析发现研究间存在异质性,但无阈值效应证据(Spearman相关系数=0.419;p=0.035)。
- Meta回归显示样本量、研究设计和诊断标准不是异质性来源,亚组荟萃分析未改变整体诊断准确性。
关键数值与推荐
- DECT诊断痛风的汇总敏感度84.7%(95%CI 81.3-87.7),汇总特异度93.7%(95%CI 93.0-96.3)。
- 阳性似然比9.882(95%CI 6.122-15.95),阴性似然比0.163(95%CI 0.097-0.272),诊断比值比78.10(95%CI 31.14-195.84)。
- AUC为0.956,Q*指数为0.889。
临床怎么用
- DECT可作为痛风诊断的高准确性影像学工具,当临床怀疑痛风时可考虑使用。
- 需结合临床情况解读DECT结果,其敏感度并非完美,阴性结果不能完全排除痛风。
局限性
- 荟萃分析发现研究间存在异质性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: This study aimed to evaluate the diagnostic performance of dual-energy computed tomography (DECT) for patients with gout. METHODS: We searched the Medline, Embase, and Cochrane Library databases, and performed a meta-analysis on the diagnostic accuracy of DECT in patients with gout. RESULTS: A total of eight studies including 510 patients with gout and 268 controls (patients with non-gout inflammatory arthritis) were available for the meta-analysis. The pooled sensitivity and specificity of DECT were 84.7% (95% confidence interval [CI]: 81.3-87.7) and 93.7% (93.0-96.3), respectively. The positive likelihood ratio, negative likelihood ratio, and diagnostic odds ratio were 9.882 (6.122-15.95), 0.163 (0.097-0.272), and 78.10 (31.14-195.84), respectively. The area under the curve of DECT was 0.956 and the Q* index was 0.889, indicating a high diagnostic accuracy. Some between-study heterogeneity was found in the meta-analyses. However, there was no evidence of a threshold effect (Spearman correlation coefficient = 0.419; p = 0.035). In addition, meta-regression showed that the sample size, study design, and diagnostic criteria were not sources of heterogeneity, and subgroup meta-analyses did not change the overall diagnostic accuracy. CONCLUSIONS: Our meta-analysis of published studies demonstrates that DECT has a high diagnostic accuracy and plays an important role in the diagnosis of gout.
引用
- Lee YH, Song GG. Diagnostic accuracy of dual-energy computed tomography in patients with gout: A meta-analysis. Semin Arthritis Rheum. 2017. PMID: 28372824. doi:10.1016/j.semarthrit.2017.03.002
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。