巨细胞动脉炎颞动脉、面动脉及腋动脉内膜-中膜厚度超声截断值
该研究纳入40例新诊断巨细胞动脉炎(GCA)患者和40例年龄性别匹配对照,在诊断时或24小时内用超声测量颞浅动脉主干、额支、顶支、面动脉及腋动脉的内膜-中膜厚度(IMT),通过ROC分析确定截断值。结果显示各动脉截断值分别为0.42、0.34、0.29、0.37和1.0 mm,对颞浅动脉主干、额支和腋动脉的敏感度和特异度均为100%。结论认为IMT测量可正确区分血管炎性与正常动脉。
要点
- 颞浅动脉主干IMT截断值0.42 mm,额支0.34 mm,顶支0.29 mm。
- 面动脉截断值0.37 mm,腋动脉1.0 mm。
- 颞浅动脉主干、额支和腋动脉的敏感度和特异度均为100%。
核心结论
- IMT测量在疑似GCA中能正确区分血管炎性与正常动脉。
研究设计与样本
- 纳入40例新诊断GCA患者和40例年龄性别匹配对照,诊断时或24小时内行超声IMT测量。
- 颞浅动脉主干及额支、顶支和面动脉用10-22 MHz探头双侧检查,腋动脉用6-18 MHz探头。
- 采用ROC分析估计截断值。
主要发现
- 对照组IMT均值:颞浅动脉主干0.23 mm(s.d. 0.04),额支0.19 mm(s.d. 0.03),顶支0.20 mm(s.d. 0.03),面动脉0.24 mm(s.d. 0.05),腋动脉0.59 mm(s.d. 0.10)。
- GCA患者血管炎段IMT均值:颞浅动脉主干0.65 mm(s.d. 0.18),额支0.54 mm(s.d. 0.18),顶支0.50 mm(s.d. 0.17),面动脉0.53 mm(s.d. 0.16),腋动脉1.7 mm(s.d. 0.41)。
- 截断值:颞浅动脉主干0.42 mm,额支0.34 mm,顶支0.29 mm,面动脉0.37 mm,腋动脉1.0 mm。
- 颞浅动脉主干、额支和腋动脉的敏感度和特异度均为100%;顶支敏感度97.2%、特异度98.7%;面动脉敏感度87.5%、特异度98.8%。
- 组内相关系数在0.87至0.98之间。
关键数值与推荐
- 颞浅动脉主干IMT截断值0.42 mm,敏感度和特异度均为100%。
- 额支IMT截断值0.34 mm,敏感度和特异度均为100%。
- 顶支IMT截断值0.29 mm,敏感度97.2%、特异度98.7%。
- 面动脉IMT截断值0.37 mm,敏感度87.5%、特异度98.8%。
- 腋动脉IMT截断值1.0 mm,敏感度和特异度均为100%。
临床怎么用
- 在疑似GCA患者中,可按上述截断值解读颞浅动脉、面动脉及腋动脉的IMT测量结果以辅助诊断。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To evaluate the intima-media thickness (IMT) of arteries involved in GCA for determining cut-off values. METHODS: Forty newly diagnosed GCA patients in a fast-track GCA clinic and 40 age- and sex-matched controls were included. IMT measurement was performed at or within 24 h after diagnosis. The common superficial temporal arteries with their frontal and parietal branches and the facial arteries were bilaterally examined with a 10-22 MHz probe and the axillary artery with a 6-18 MHz probe. Receiver operating characteristics analysis was performed for estimating cut-off values. RESULTS: The mean age was 72 years (s.d. 9) and 68% were females. In the control group, IMT was 0.23 mm (s.d. 0.04), 0.19 mm (s.d. 0.03), 0.20 mm (s.d. 0.03), 0.24 mm (s.d. 0.05) and 0.59 mm (s.d. 0.10) for the common superficial temporal arteries, the frontal and parietal branches, the facial arteries and the axillary arteries, respectively. In vasculitic segments of GCA patients, IMT was 0.65 mm (s.d. 0.18), 0.54 mm (s.d. 0.18), 0.50 mm (s.d. 0.17), 0.53 mm (s.d. 0.16) and 1.7 mm (s.d. 0.41), respectively. Cut-off values are 0.42, 0.34, 0.29, 0.37 and 1.0 mm, respectively, with 100% sensitivities and specificities for common superficial temporal arteries, for frontal branches and for axillary arteries and sensitivities of 97.2 and 87.5% and specificities of 98.7 and 98.8% for parietal branches and facial arteries, respectively. The intraclass correlation coefficient was between 0.87 and 0.98. CONCLUSION: IMT measurement can correctly distinguish vasculitic from normal arteries in suspected GCA.
引用
- Schäfer VS, Juche A, Ramiro S, et al. Ultrasound cut-off values for intima-media thickness of temporal, facial and axillary arteries in giant cell arteritis. Rheumatology (Oxford). 2017. PMID: 28431106. doi:10.1093/rheumatology/kex143
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。