手部关节位置影响RA超声检查:中立位较平放位能量多普勒信号增高
一项横断面研究纳入42例活动性RA患者,比较手部中立位与平放位超声下灰阶滑膜炎和能量多普勒信号差异。结果显示平放位时二维能量多普勒信号在28.3%关节中消失,整体二维和三维能量多普勒评分均显著下降,提示中立位检测能量多普勒信号敏感性更高。
要点
- 平放位时28.3%关节的二维能量多普勒信号消失,中立位检测敏感性更高。
- 整体二维能量多普勒评分中位数从中立位8降至平放位3(P<0.001)。
- 整体三维能量多普勒体素评分中位数从3.8降至0.9(P<0.001)。
核心结论
- 在活动性RA患者中,手部中立位较平放位在腕关节和掌指关节检测能量多普勒信号时具有更高的敏感性。
研究设计与样本
- 横断面研究,纳入42例活动性RA患者,对腕关节和掌指关节行二维及三维超声检查,比较中立位与平放位下的灰阶滑膜炎和能量多普勒信号。
主要发现
- 与中立位相比,平放位时28.3%关节的二维能量多普勒信号消失。
- 整体二维能量多普勒评分中位数从中立位8降至平放位3(P<0.001)。
- 整体三维能量多普勒体素评分中位数从3.8降至0.9(P<0.001)。
- 各关节能量多普勒评分下降程度相似(二维下降50%,三维下降66.4-80.1%)。
- 能量多普勒结果的评估者间和评估者内一致性良好(组内相关系数0.75-0.82)。
临床怎么用
- 在RA临床试验和临床常规中,应标准化超声扫描时手部关节位置,建议采用中立位以提高能量多普勒检测敏感性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Position of joints might influence the result of US examination in patients with RA. The purpose of this work was to compare grey-scale (GS) and power Doppler (PWD) findings obtained in neutral vs flat position of hands. METHODS: A cross-sectional study of 42 RA patients with active disease. Two dimensional and 3D sonography of wrists and MCP joints were conducted in two different joint positions: neutral position, which is a slight flexion of the fingers with relaxed extensor muscles; and flat position, where all palm and volar sides of fingers touch the Table. Two dimensional GS synovitis (GSS) and PWD signals were scored semi-quantitatively (0-3). For 3D sonography, the percentage of PWD voxels within a region of interest was calculated. GSS was not quantified using 3D sonography. RESULTS: Compared with neutral position, 2D PWD signals disappeared in 28.3% of joints upon flattening. The median global 2D PWD score (sum of all PWD scores of an individual patient) decreased from 8 to 3 ( P < 0.001), and the global 3D PWD voxel score from 3.8 to 0.9 ( P < 0.001). The reduction of PWD scores was similar in all joints (2D: minus 50%, 3D: minus 66.4-80.1%). Inter- and intrareader agreement of PWD results was good (intraclass correlation coefficient: 0.75-0.82). CONCLUSION: In RA, a neutral position of the hands is linked to a higher sensitivity of 2D and 3D sonography in detecting PWD signals at wrists and MCP joints, compared with a flat position. Standardization of the scanning procedure is essential for obtaining comparable US results in RA patients in trials and clinical routines.
引用
- Husic R, Lackner A, Stradner MH, et al. Joint positions matter for ultrasound examination of RA patients-increased power Doppler signal in neutral versus flat position of hands. Rheumatology (Oxford). 2017. PMID: 28431182. doi:10.1093/rheumatology/kex153
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。