文献速递脊柱关节炎

ASAS中轴型与外周型脊柱关节炎分类标准性能的系统综述与荟萃分析

Performance of the ASAS classification criteria for axial and peripheral spondyloarthritis: a systematic literature review and meta-analysis.
PubMed 文献 · Ann Rheum Dis · 2017-02-08

该系统综述与荟萃分析纳入9篇文献共5739例患者,以风湿科医生诊断为参照标准,评估ASAS脊柱关节炎分类标准的性能。结果显示整套ASAS SpA标准汇总敏感度73%、特异度88%,中轴型标准敏感度82%、特异度88%,外周型标准敏感度63%、特异度87%。

要点

  • 整套ASAS SpA标准汇总敏感度73%、特异度88%。
  • 中轴型标准敏感度82%、特异度88%,性能良好。
  • 仅影像臂敏感度30%、仅临床臂23%,但特异度分别达97%和94%。

核心结论

  • 累计超过5500例患者的证据证实,以风湿科医生诊断为参照标准,ASAS各套SpA分类标准性能良好。

研究设计与样本

  • 系统文献综述筛选合格研究,提取SpA诊断与分类原始数据,必要时向原作者获取。
  • 采用随机效应模型进行荟萃分析,汇总敏感度、特异度、阳性和阴性似然比。
  • 共纳入9篇论文,合计N=5739例患者。

主要发现

  • 整套ASAS SpA标准汇总敏感度73%、特异度88%。
  • 中轴型SpA标准汇总敏感度82%、特异度88%。
  • 仅影像臂敏感度30%、仅临床臂敏感度23%,特异度分别为97%和94%。
  • 外周型SpA标准汇总敏感度63%、特异度87%,较中轴型标准更少被测试。

关键数值与推荐

  • 整套ASAS SpA标准:敏感度73%,特异度88%。
  • 中轴型SpA标准:敏感度82%,特异度88%;仅影像臂敏感度30%、特异度97%;仅临床臂敏感度23%、特异度94%。
  • 外周型SpA标准:敏感度63%,特异度87%。

临床怎么用

  • 在临床研究中,ASAS中轴型SpA标准以风湿科医生诊断为参照具有较高敏感度和特异度。
  • 仅使用影像臂或仅使用临床臂时敏感度明显下降,但特异度很高。
  • 外周型SpA标准敏感度较低,应用时需注意漏分类可能。

局限性

  • 外周型SpA标准被测试的研究较少。
  • 仅影像臂和仅临床臂的敏感度明显低于整套标准。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To summarise the evidence on the performance of the Assessment of SpondyloArthritis international Society (ASAS) classification criteria for axial spondyloarthritis (axSpA) (also imaging and clinical arm separately), peripheral (p)SpA and the entire set, when tested against the rheumatologist's diagnosis ('reference standard'). METHODS: A systematic literature review was performed to identify eligible studies. Raw data on SpA diagnosis and classification were extracted or, if necessary, obtained from the authors of the selected publications. A meta-analysis was performed to obtain pooled estimates for sensitivity, specificity, positive and negative likelihood ratios, by fitting random effects models. RESULTS: Nine papers fulfilled the inclusion criteria (N=5739 patients). The entire set of the ASAS SpA criteria yielded a high pooled sensitivity (73%) and specificity (88%). Similarly, good results were found for the axSpA criteria (sensitivity: 82%; specificity: 88%). Splitting the axSpA criteria in 'imaging arm only' and 'clinical arm only' resulted in much lower sensitivity (30% and 23% respectively), but very high specificity was retained (97% and 94% respectively). The pSpA criteria were less often tested than the axSpA criteria and showed a similarly high pooled specificity (87%) but lower sensitivity (63%). CONCLUSIONS: Accumulated evidence from studies with more than 5500 patients confirms the good performance of the various ASAS SpA criteria as tested against the rheumatologist's diagnosis.

来源:Ann Rheum Dis,查看原文。版权归原作者所有。

引用

  1. Sepriano A, Rubio R, Ramiro S, et al. Performance of the ASAS classification criteria for axial and peripheral spondyloarthritis: a systematic literature review and meta-analysis. Ann Rheum Dis. 2017. PMID: 28179264. doi:10.1136/annrheumdis-2016-210747

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。