文献速递类风湿关节炎

类风湿关节炎滑膜炎多普勒超声半定量与定量评分的一致性及差异原因分析

Analysis of correlation and causes for discrepancy between quantitative and semi-quantitative Doppler scores in synovitis in rheumatoid arthritis.
PubMed 文献 · Rheumatology (Oxford) · 2016-11-14

本研究纳入对抗风湿治疗反应不足的成人RA患者,对腕、MCP及MTP 2-5背侧行肌骨超声检查,收集有滑膜炎征象的图像并测量多普勒像素定量评分(QS),由5名评估者盲法独立按两种半定量评分(SQS)方法评分。共分析1190次评分,QS与SQS呈强相关(ρ=0.89,P<0.0001),两种SQS方法相关性相似;239张(20.1%)图像SQS分级与基于QS预设切点的预期分级不符,主要原因为感知感兴趣区不同(40.7%)和多普勒像素计数接近SQS分级切点(32.3%)。

要点

  • QS与SQS强相关(ρ=0.89,P<0.0001),Szkudlarek与Hammer法相关性相似。
  • 20.1%图像SQS分级与基于QS切点的预期不符,差异主因感兴趣区感知不同及像素数接近切点。
  • SQS在像素计数接近分级切点时存在固有局限,差异分析有助于修订RA肌骨超声活动度评估标准。

核心结论

  • 两种SQS方法均与QS评估滑膜炎相关性良好,但SQS在像素计数接近分级切点时存在固有局限。

研究设计与样本

  • 研究纳入对抗风湿治疗反应不足的成人RA患者,行腕、MCP及MTP 2-5背侧肌骨超声,收集滑膜炎图像并测QS,5名评估者盲法按两种SQS独立评分。

主要发现

  • 分析1190次评分,QS与SQS强相关(ρ=0.89,P<0.0001)且关联显著(P<0.0001)。
  • 按Szkudlarek法(ρ=0.87,P<0.0001)与Hammer法(ρ=0.91,P<0.0001)的QS-SQS相关性相似。
  • 239张(20.1%)图像SQS分级与基于QS预设切点的预期分级不符。
  • 差异主因为感知感兴趣区不同(40.7%)和多普勒像素计数接近SQS分级切点(32.3%)。

关键数值与推荐

  • QS与SQS总体相关系数ρ=0.89(P<0.0001)。
  • Szkudlarek法QS-SQS相关系数ρ=0.87(P<0.0001),Hammer法ρ=0.91(P<0.0001)。
  • SQS分级与基于QS预设切点预期不符的图像239张,占20.1%。
  • 差异原因中感知感兴趣区不同占40.7%,像素计数接近切点占32.3%。

临床怎么用

  • 临床采用SQS评估RA滑膜炎时,应关注像素计数接近分级切点的图像,警惕分级偏差。
  • 判读时需规范感兴趣区界定,以减少SQS与QS之间的分级差异。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: The aim of this study was to evaluate the association between two semi-quantitative Doppler US scoring systems (SQS), and the quantitative scoring (QS) of Doppler pixel count. METHODS: Adult patients with RA and inadequate clinical response to anti-rheumatic therapy were examined with musculoskeletal US (MSUS). Dorsal MSUS of the wrists, MCP and MTP 2-5 were performed. MSUS images with sign of synovitis were collected and the QS was measured. Five assessors blinded to the QS evaluated the images independently, according to either SQS method. Association between QS and SQS was studied using correlations and multilevel models taking into account the clustering of ratings at the rater, patient and joint levels. RESULTS: Analysis of the 1190 ratings revealed a strong correlation (ρ = 0.89, P < 0.0001) and significant associations (P < 0.0001) between QS and SQS. Correlations between QS and SQS according to Szkudlarek et al. (ρ = 0.87, P < 0.0001) or Hammer et al. (ρ = 0.91, P < 0.0001) were similar. A total of 239 (20.1%) images were given a SQS grade that did not match that expected based on initial QS, using pre-defined cut-offs. Main explanations for discrepancies were different perceived region of interest (40.7%) and Doppler pixel count near cut-offs between SQS grades (32.3%). CONCLUSION: We showed that both SQS methods correlated well with QS to assess synovitis, but SQS methods are intrinsically limited when the Doppler pixel count is close to the cut-offs between the SQS grades. Analysis discrepancies between these methods may help further revision of criteria used to assess disease activity with MSUS in RA.

来源:Rheumatology (Oxford),查看原文。版权归原作者所有。

引用

  1. Rezaei H, Af Klint E, Hammer HB, et al. Analysis of correlation and causes for discrepancy between quantitative and semi-quantitative Doppler scores in synovitis in rheumatoid arthritis. Rheumatology (Oxford). 2016. PMID: 28123118. doi:10.1093/rheumatology/kew385

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。