文献速递类风湿关节炎

多阅片者评估可替代参考评估以提升类风湿关节炎影像学进展检出

Multireader assessment as an alternative to reference assessment to improve the detection of radiographic progression in a large longitudinal cohort of rheumatoid arthritis (ESPOIR).
PubMed 文献 · RMD Open · 2017-01-04

在ESPOIR早期关节炎队列524例患者中,比较10名经培训风湿科医生多阅片者评分与2名经验丰富读片者参考评分对van der Heijde改良Sharp评分(SHS)进展和显著影像学进展(SRP)的再现性。多阅片者与参考评估在SHS进展和SRP评估上几乎完全一致,ICC分别为0.88(95%CI 0.82–0.93)和0.99(95%CI 0.99–0.99),提示多阅片者评估可提高大样本纵向队列影像学评分可行性。

要点

  • 多阅片者与参考评估SHS进展一致性ICC为0.88(95%CI 0.82–0.93)。
  • 多阅片者与参考评估SRP一致性ICC为0.99(95%CI 0.99–0.99)。
  • 培训期间读片者内部和读片者间再现性分别从ICC 0.79升至0.94和从0.76升至0.92。

核心结论

  • 多阅片者评估影像学结构损伤进展与参考评估相当,可用于提高大样本纵向队列影像学评分可行性。

研究设计与样本

  • 基于ESPOIR早期关节炎队列中M0和M60有完整影像学数据的524例患者,12名风湿科医生经3次培训后,10名读片者随机抽样评分全部影像的1/5(每套X线双评分),与2名经验丰富读片者的参考评分比较。

主要发现

  • 多阅片者与参考评估SHS进展一致性ICC为0.88(95%CI 0.82–0.93)。
  • 多阅片者与参考评估SRP一致性ICC为0.99(95%CI 0.99–0.99)。
  • 培训期间读片者内部再现性ICC从0.79升至0.94,读片者间再现性ICC从0.76升至0.92。

关键数值与推荐

  • SHS进展和SRP评估采用组内相关系数(ICC)比较多阅片者与参考评估的一致性。
  • 评分采用van der Heijde改良Sharp评分(SHS),读片者对临床数据盲法,X线按时间顺序评分。

临床怎么用

  • 在大型纵向队列中可采用多阅片者评估替代参考评估进行影像学结构损伤进展评分,以提高可行性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

INTRODUCTION: Structural damage progression is a major outcome in rheumatoid arthritis (RA). Its evaluation and follow-up in trials should involve radiographic scoring by 1 or 2 readers (reference assessment), which is challenging in large longitudinal cohorts with multiple assessments. OBJECTIVES: To compare the reproducibility of multireader and reference assessment to improve the feasibility of detecting radiographic progression in a large cohort of patients with early arthritis (ESPOIR). METHODS: We used 3 sessions to train 12 rheumatologists in radiographic scoring by the van der Heijde-modified Sharp score (SHS). Multireader scoring was based on 10 trained-reader assessments, each reader scoring a random sample of 1/5 of all available radiographs (for double scoring for each X-ray set) for patients included in the ESPOIR cohort with complete radiographic data at M0 and M60. Reference scoring was performed by 2 experienced readers. Scoring was performed blindly to clinical data, with radiographs in chronological order. We compared multireader and reference assessments by intraclass correlation coefficients (ICCs) for SHS and significant radiographic progression (SRP). RESULTS: The intrareader and inter-reader reproducibility for trained assessors increased during the training sessions (ICC 0.79 to 0.94 and 0.76 to 0.92), respectively. For the 524 patients included, agreement between multireader and reference assessment of SHS progression between M0 and M60 and SRP assessment were almost perfect, ICC (0.88 (95% CI 0.82 to 0.93)) and (0.99 (95% CI 0.99 to 0.99)), respectively. CONCLUSIONS: Multireader assessment of radiographic structural damage progression is comparable to reference assessment and could be used to improve the feasibility of radiographic scoring in large longitudinal cohort with numerous X-ray evaluations.

来源:RMD Open,查看原文。版权归原作者所有。

引用

  1. Gandjbakhch F, Granger B, Freund R, et al. Multireader assessment as an alternative to reference assessment to improve the detection of radiographic progression in a large longitudinal cohort of rheumatoid arthritis (ESPOIR). RMD Open. 2017. PMID: 28123779. doi:10.1136/rmdopen-2016-000343