文献速递类风湿关节炎

类风湿关节炎全球OMERACT超声关节损伤评分系统(GLODS)

A global OMERACT ultrasound joint damage scoring system (GLODS) in rheumatoid arthritis.
PubMed 文献 · Ann Rheum Dis · 2026-08-01

研究通过德尔菲调查就超声结构损伤的定义与半定量评分达成共识,并在网络和现场练习中检验GLODS各组件及总分的信度。结果显示各组件信度良好至优秀,总分观察者内信度优秀(0.92)、观察者间信度良好(0.69)。

要点

  • 超声可可靠评估RA手关节骨侵蚀、软骨改变和关节对线不良。
  • GLODS总分观察者内信度优秀(0.92),观察者间信度良好(0.69)。

核心结论

  • 超声是评估RA手关节骨侵蚀、软骨改变和关节对线不良的可靠工具,这些特征可可靠整合为全局超声评分。

研究设计与样本

  • 德尔菲调查(4轮)就9条声明达成共识,随后创建超声图像数据集进行2次网络练习,并由7名任务组成员对7例RA患者的第1至5掌指关节进行同日两次超声扫描。

主要发现

  • 各组件观察者内和观察者间信度在网络练习(0.72-0.97)和现场练习(0.68-0.89)中均为良好至优秀。
  • GLODS总分观察者内信度优秀(0.92),观察者间信度良好(0.69)。

关键数值与推荐

  • 德尔菲共识定义为≥75%的评分在1-5 Likert量表上为4-5级。
  • 信度以加权kappa衡量。

临床怎么用

  • GLODS可用于RA手关节超声结构损伤的半定量评估,各组件及总分信度可接受。

局限性

  • 仅纳入7例RA患者及7名任务组成员,样本量小。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: This study aimed to develop consensual definitions and semiquantitative scoring for structural damage on ultrasound and to test the reliability of individual components of a global Outcome Measures in Rheumatology ultrasound joint damage score (GLODS) in rheumatoid arthritis (RA). METHODS: A Delphi survey including statements on normal ultrasound appearance of joint features, scanning technique, new definitions, and scoring systems for 3 components of structural damage (bone erosions, cartilage change, and joint malalignment) was circulated among task force members. After agreement (≥75% of grades 4-5 on a 1-5 Likert scale) was achieved on the statements, datasets of ultrasound images representing various grades of the above-mentioned structural damage components were created and used in 2 web-based exercises. Finally, the metacarpophalangeal joints 1 to 5 of 7 patients with RA were scanned with ultrasound, twice on the same day by 7 task force members for detecting and scoring the 3 components using the consensus-based semiquantitative GLODS. Intraobserver and interobserver reliability of the new scoring system was measured by weighted kappa. RESULTS: Agreement on a total of 9 statements was reached in 4 Delphi rounds. Intraobserver and interobserver reliability for the individual components ranged from good to excellent in both the web-based (0.72-0.97) and the live exercises (0.68-0.89). Intraobserver and interobserver reliability of the total GLODS was shown to be excellent (0.92) and good (0.69), respectively. CONCLUSIONS: Ultrasound is a reliable tool for evaluating bone erosions, cartilage change, and joint malalignment in the hand joints of patients with RA. These features can be reliably integrated into a global ultrasound score.

来源:Ann Rheum Dis,查看原文。版权归原作者所有。

引用

  1. Mandl P, Gessl I, Kun L, et al. A global OMERACT ultrasound joint damage scoring system (GLODS) in rheumatoid arthritis. Ann Rheum Dis. 2026. PMID: 42542402. doi:10.1016/j.ard.2026.07.004

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。