唇腺超高频超声在干燥病中的诊断准确性与患者分层
本研究纳入270例疑似干燥病(SjD)患者(136例SjD,134例口干症),评估唇腺超高频超声(UHFUS)联合灰阶(GS)与彩色多普勒(CD)的分类准确性。GS≥2为最佳分类截断值,敏感度66.2%、特异度84.3%;将GS替代活检纳入ACR/EULAR标准获得优异准确性(AUC 0.945)。GS+CD及SSA状态可对超过75%患者以94%准确性分类,聚类分析提示不同表型。
要点
- 唇腺UHFUS的GS≥2分类截断值敏感度66.2%、特异度84.3%。
- GS替代活检纳入ACR/EULAR标准AUC达0.945。
- GS+CD与SSA状态联合可对超过75%患者以94%准确性分类。
核心结论
- 唇腺UHFUS是活检不可行时干燥病有前景的诊断工具。
- GS联合CD及SSA状态有助于患者分层并提示不同表型。
- GS分类准确性随年龄变化,而CD保持稳定。
研究设计与样本
- 纳入270例疑似干燥病患者(136例SjD,134例口干症)行唇腺UHFUS检查。
- 评估OMERACT GS(改良用于唇腺)、CD及GS+CD复合评分,并分析GS形态学病变。
- 采用相关分析、逻辑回归和聚类分析进行统计学处理。
主要发现
- 最佳分类截断值为GS≥2,敏感度66.2%、特异度84.3%。
- GS评分3高度特异(98.5%),极低回声区仅见于SjD。
- CD≥2准确性可与GS媲美,GS+CD≥3进一步提升准确性。
- 聚类分析提示口干症中GS阳性提示非免疫性炎症改变或涎腺病,SjD中GS阴性定义低度炎症。
关键数值与推荐
- GS≥2为最佳分类截断值(敏感度66.2%,特异度84.3%)。
- GS评分3特异度98.5%。
- GS替代活检纳入ACR/EULAR标准AUC为0.945。
- GS+CD与SSA状态联合使超过75%患者以94%准确性分类。
临床怎么用
- 活检不可行时可考虑唇腺UHFUS辅助干燥病诊断。
- GS≥2可作为分类参考截断值,GS评分3高度提示SjD。
- 联合GS、CD与SSA状态有助于患者分层。
- 解读GS结果时需考虑年龄相关分类变异性,CD相对稳定。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: To evaluate the classification accuracy of ultra-high frequency ultrasound (UHFUS) of labial salivary glands (LSGs) using both Grey Scale (GS) and colour Doppler (CD). We also investigated its role as an alternative to the highest-weighted classification criteria, its classification performance in combination with SSA status, its contribution to patient stratification and age-related classification variability. METHODS: A total of 270 patients with suspected Sjögren's disease (SjD) (136 SjD, 134 Sicca) underwent UHFUS. In addition to OMERACT GS (modified to LSG), CD and composite GS+CD Scores, distinct GS morphological lesions were assessed. Diagnostic accuracy parameters were calculated, and additional analyses included correlation, logistic regression and cluster analysis. RESULTS: The optimal classification cut-off was GS ≥2, yielding 66.2% sensitivity and 84.3% specificity. GS Score 3 was highly specific (98.5%), while very hypoechoic areas were exclusively observed in SjD. CD ≥2 showed accuracy comparable to GS, and GS+CD ≥3 enhanced accuracy. Incorporating GS into the American College of Rheumatology/European League Against Rheumatism criteria in place of biopsy achieved excellent accuracy (area under the curve 0.945). Using GS, GS+CD and SSA status, more than 75% of patients could be classified with an accuracy of 94%. Cluster analysis suggests different phenotypes: in Sicca, GS positivity indicated non-immune inflammatory alterations or sialoadenosis; in SjD, GS negativity defined low-grade inflammation. Classification accuracy of GS varied with age, whereas CD remained stable. CONCLUSIONS: UHFUS of LSGs is a promising diagnostic tool in SjD when biopsy is not feasible. This study provides novel insights into GS lesions, Doppler assessment, phenotypes and age-related changes of ultrasound.
引用
- Fulvio G, Izzetti R, Ferro F, et al. Ultra-high frequency ultrasound of labial salivary glands in Sjögren's disease: diagnostic accuracy and patient stratification. RMD Open. 2026. PMID: 42399077. doi:10.1136/rmdopen-2026-006906
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。