电子痛风发作评估方案的信度评估
本研究基于TRUST随机临床试验的便利样本,比较电子自我报告与电话问卷两种痛风发作评估方式的一致性。28例患者完成12周试点,共109个发作期,电子与电话评估的原始一致率为96%,ICC为0.880,混合效应ICC为0.746,表明两种方式高度一致。
要点
- 电子自我报告与电话问卷评估痛风发作的原始一致率达96%。
- ICC为0.880,混合效应ICC为0.746,支持电子评估的可靠性。
- 电子调查可作为电话评估的准确高效替代方案。
核心结论
- 电子自我报告与电话问卷评估痛风发作在多种等效性检验中均显示高度一致性,支持电子调查作为电话评估的准确高效替代方案。
研究设计与样本
- 研究为TRUST随机临床试验的便利样本试点,患者每两周完成电子调查报告痛风发作,研究 staff 盲法通过标准双周电话访问确认电子报告。
主要发现
- 28例患者(平均年龄60.5岁,SD 13;93%男性)参与12周试点,完成109个发作期,其中电子评估108次、电话评估99次。
- 电子调查报告23次发作,电话调查报告22次发作。
- 电子与电话评估的原始一致率为96%。
- ICC为0.880,混合效应ICC为0.746。
关键数值与推荐
- 采用百分比一致率、Cohen's kappa、Gwen's AC1统计量、McNemar等效性检验和组内相关系数(ICC)评估一致性,必要时用非参数自举法计算95%置信区间。
临床怎么用
- 在痛风临床试验或临床随访中,可考虑使用电子自我报告替代电话问卷评估痛风发作,以提高效率并减少人力成本。
局限性
- 本研究为小样本试点(28例),样本以男性为主(93%),结论需在更大规模人群中验证。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Most trials in gout focus on serum urate changes because assessing gout flares is difficult. We evaluated the reliability of an electronic, self-reported gout flare assessment compared to a staff-conducted telephone questionnaire. METHODS: A convenience sample of participants from the Treat-to-Target Serum Urate Versus Treat-to-Avoid Symptoms in Gout (TRUST) randomized clinical trial, which examines gout flares as a primary outcome, completed biweekly electronic surveys reporting gout flares. Study staff blinded to treatment assignment conducted a gout flare assessment at standard biweekly telephone visits to confirm electronic reports. We assessed agreement between flare assessment modalities using multiple assessments such as percent agreement, Cohen's kappa, Gwen's AC1 statistic, McNemar's test of equivalence, and intraclass correlation coefficient (ICC). In addition, we accounted for repeated measures within patients using mixed effects models, presenting a mixed effects ICC. Where necessary, 95% confidence intervals were calculated using nonparametric bootstrapping. RESULTS: A total of 28 patients (mean age 60.5 years, SD 13; 93% male) participated in the 12-week pilot, completing 109 flare periods with 108 electronic and 99 phone assessments. Patients reported 23 flares on electronic surveys and 22 flares on phone surveys. We observed a raw percent agreement between survey types of 96%. All measures of agreement consistently demonstrated strong concordance, with an ICC of 0.880 and a mixed effects ICC of 0.746. CONCLUSION: The pilot study shows strong agreement between electronic and telephone gout flare assessments across multiple equivalence tests, supporting electronic surveys as an accurate and efficient alternative to phone assessments.
引用
- Chitineni S, Solomon DH, Choi H, et al. Assessing Reliability of an Electronic Gout Flare Assessment Protocol. Arthritis Care Res (Hoboken). 2026. PMID: 42328908. doi:10.1002/acr.80105
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。