指南与共识其他结缔组织病

依据2017 EULAR建议标准化干燥病小唾液腺活检判读的单中心研究

Standardization of minor salivary gland biopsy interpretation in Sjögren's disease using the 2017 EULAR recommendations: a monocentric study.
指南 / 共识 · Rheumatology (Oxford) · 2026-01-01

该单中心研究由两名病理学家评估疑似干燥病(SjD)患者小唾液腺活检(MSGB)判读的评估者间与评估者内信度,遵循2017 EULAR建议的标准化盲法方案。结果显示腺体面积、二分法灶性评分(FS≥1或<1)及局灶性淋巴细胞性涎腺炎(FLS)诊断的κ≥0.6,结构损伤评估的κ≤0.4,FS的ICC在评估者间及评估者内比较中均≥0.61。结论认为FLS诊断与FS判读信度良好,而结构损伤分级信度有限。

要点

  • FLS诊断与二分法FS判读的评估者间及评估者内信度均达κ≥0.6。
  • 结构损伤评估的评估者间及评估者内信度仅κ≤0.4。
  • FS的ICC在评估者间比较中≥0.61,在评估者内及部分评估者间比较中≥0.76。

核心结论

  • 依据2017 EULAR建议判读MSGB时,FLS诊断与FS判读的信度良好,但结构损伤分级信度有限。

研究设计与样本

  • 单中心研究,由两名病理学家评估疑似SjD患者MSGB判读的可重复性。
  • 评估者内信度:专家A按标准化盲法方案在间隔2个月后对196张切片评估两次。
  • 评估者间信度:专家A的初次评估与常规病理学家及独立评估115张随机切片子集的专家B比较。

主要发现

  • 腺体面积、二分法FS(≥1或<1)及FLS诊断的评估者间与评估者内一致性达κ≥0.6。
  • 结构损伤评估的评估者间与评估者内一致性仅κ≤0.4。
  • FS的ICC在常规病理学家与专家A之间≥0.61,在专家A与专家B之间及专家A评估者内比较中≥0.76。

关键数值与推荐

  • FLS诊断、二分法FS及腺体面积的评估者间与评估者内一致性阈值:κ≥0.6。
  • 结构损伤评估的评估者间与评估者内一致性阈值:κ≤0.4。
  • FS的ICC信度阈值:常规病理学家与专家A之间≥0.61,专家A与专家B之间及专家A评估者内比较≥0.76。

临床怎么用

  • 在临床与研究场景中判读MSGB时,FLS诊断与二分法FS判读可较可靠地重复。
  • 结构损伤评估的信度有限,需谨慎解读并加强病理学家培训与组织病理学流程标准化。

局限性

  • 单中心研究,评估者数量有限,结果外推需谨慎。
  • 结构损伤评估的信度有限,可能反映培训与标准不一致,而非排除其他影响因素。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To assess the inter- and intra-rater reliability of minor salivary gland biopsy (MSGB) interpretation for the evaluation of Sjögren's disease (SjD), in accordance with the 2017 EULAR recommendations. METHODS: The reproducibility of MSGB findings in patients with suspected SjD was analysed by two pathologists. For intra-rater reliability, expert examiner A (ExA) evaluated 196 slides twice, with a 2-month interval, following a standardized blinded protocol. For inter-rater reliability, ExA's initial assessment was compared with that of the routine service pathologists (ExR) and with expert examiner B (ExB), who independently evaluated a random subset of 115 slides. Agreement for qualitative variables was assessed using Cohen's kappa coefficient (κ), and the intraclass correlation coefficient (ICC) was calculated for quantitative measures. RESULTS: Inter- and intra-rater analyses demonstrated substantial to almost perfect agreement (κ ≥ 0.6) for glandular area, dichotomized focus score (FS; ≥1 or <1) and the diagnosis of focal lymphocytic sialadenitis (FLS). In contrast, agreement for structural damage assessment was only moderate to fair (κ ≤ 0.4) across both analyses. The ICC for FS indicated good reliability (≥0.61) between ExR and ExA, and almost perfect reliability (ICC ≥0.76) between ExA and ExB, as well as within ExA's intra-rater comparison. CONCLUSION: Inter- and intra-rater reliability for diagnosing FLS and determining FS is good, whereas reliability for grading structural damage remains limited. This discrepancy may reflect less consistent training and criteria for assessing tissue damage compared with inflammatory features. Improving MSGB reproducibility will require stronger standardization of histopathological procedures and enhanced pathologist training.

来源:Rheumatology (Oxford),查看原文。版权归原作者所有。

引用

  1. Xavier CGV, Cerqueira Calderaro D, de Almeida Araújo S, et al. Standardization of minor salivary gland biopsy interpretation in Sjögren's disease using the 2017 EULAR recommendations: a monocentric study. Rheumatology (Oxford). 2026. PMID: 42348239. doi:10.1093/rheumatology/keag333

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。