文献速递脊柱关节炎

中轴型脊柱关节炎脊柱结构损伤评估:基于MRI合成CT的国际OMERACT多读者研究

Structural damage assessment in the spine of patients with axial spondyloarthritis - results from an international OMERACT multi-reader exercise using MRI-based synthetic CT.
PubMed 文献 · Semin Arthritis Rheum · 2026-06-04

该研究由OMERACT MRI工作组制定脊柱新骨形成的共识定义,并初步验证基于MRI的合成CT(sCT)评估中轴型脊柱关节炎脊柱结构损伤的效力。

要点

  • OMERACT工作组建立脊柱新骨形成共识定义及评分规则。
  • sCT评估脊柱结构损伤敏感性0.77,特异性≥0.94。
  • sCT读者间信度ICC 0.86,与低剂量CT相当。

核心结论

  • sCT满足OMERACT领域匹配和可行性关键标准,有望成为脊柱关节炎临床试验中评估脊柱结构损伤的新方法。

研究设计与样本

  • OMERACT MRI工作组通过共识会议制定脊柱新骨形成定义和评分规则。
  • sCT图像使用深度学习算法(BoneMRI v1.8)重建。

主要发现

  • 所有参与者中sCT和低剂量CT平均共评分35.5个病灶。
  • 以低剂量CT为参考标准,sCT总体敏感性0.77,特异性≥0.94。
  • 读者间一致性:低剂量CT总体ICC 0.80,sCT总体ICC 0.86;对应kappa值分别为0.68和0.70。

关键数值与推荐

  • 共识定义涵盖边缘性韧带骨赘、非边缘性韧带骨赘和骨赘。
  • sCT敏感性0.77,特异性≥0.94(以低剂量CT为参考标准)。
  • 低剂量CT的ICC为0.80,sCT的ICC为0.86;kappa值分别为0.68和0.70。

临床怎么用

  • sCT可作为中轴型脊柱关节炎临床试验中评估脊柱结构损伤的MRI替代方法。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To develop and perform preliminary cross-sectional validation of a magnetic resonance imaging (MRI)-based outcome measure for assessing spinal structural damage in spondyloarthritis clinical trials, with a specific focus on MRI-based synthetic computed tomography (sCT) and related MRI-based techniques. METHODS: Consensus meetings within the Outcome Measures in Rheumatology (OMERACT) MRI in arthritis working group established consensus definitions for spinal new bone formation and scoring rules. Then, low-dose CT and sCT images of twenty patients with axial spondyloarthritis and five healthy controls were independently assessed by seven experienced readers using the agreed-upon definitions for: marginal syndesmophytes, non-marginal syndesmophytes, and osteophytes. sCT images were reconstructed using a deep learning algorithm (BoneMRI v1.8, MRIGuidance B.V., Utrecht, the Netherlands). Sensitivity and specificity of synthetic CT were calculated using low-dose CT as the reference standard, and inter-reader reliability was assessed. RESULTS: A total mean of 35.5 lesions was scored on both sCT and low-dose CT in all participants. sCT demonstrated an overall good sensitivity (0.77) and excellent specificity (≥ 0.94) with low-dose CT as reference standard. Inter-reader agreement was substantial for both low-dose CT and sCT, with an overall intra-class coefficient of 0.80 (low-dose CT) and 0.86 (sCT), and corresponding kappa values of 0.68 and 0.70, respectively. CONCLUSION: This OMERACT international multi-reader exercise established consensus definitions for spinal new bone formation and provided preliminary evidence that sCT meets key OMERACT criteria of domain match and feasibility. This MRI technique for generating CT-like images shows promise as a novel method for assessing spinal structural damage in spondyloarthritis clinical trials.

来源:Semin Arthritis Rheum,查看原文。版权归原作者所有。

引用

  1. Willesen ST, Lambert RGW, Maksymowych WP, et al. Structural damage assessment in the spine of patients with axial spondyloarthritis - results from an international OMERACT multi-reader exercise using MRI-based synthetic CT. Semin Arthritis Rheum. 2026. PMID: 42308963. doi:10.1016/j.semarthrit.2026.153013

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。