特发性炎性肌病超声共识定义与信度:OMERACT肌炎工作组初步数据
OMERACT超声肌炎工作组通过多轮德尔菲调查和基于网络的信度测试,为特发性炎性肌病(IIM)制定超声基本病变的共识定义。初步将「炎症」和「损伤」两个领域修订为单一「肌肉炎症与损伤」领域,包含回声性和筋膜厚度等基本成分,并测试分类形态学评分系统,显示良好组内信度和中等组间信度。
要点
- 初步「炎症」和「损伤」领域组内信度较高但组间信度差。
- 共识修订为单一「肌肉炎症与损伤」领域,含回声性和筋膜厚度。
- 分类形态学评分系统显示组内信度较高、组间信度中等。
核心结论
- OMERACT超声肌炎工作组通过系统方法制定了IIM超声领域的共识定义和分类形态学评分系统。
- 该评分系统在基于网络的信度测试中显示中等组间信度。
研究设计与样本
- 多中心21名国际专家参与多轮德尔菲调查,随后进行基于网络的信度测试。
主要发现
- 初步「炎症」和「损伤」领域组内信度kappa分别为0.662和0.620,组间信度kappa分别为0.142和0.112。
- 修订为单一「肌肉炎症与损伤」领域后,分类形态学评分系统组内信度kappa为0.706(min 0.051,max 1.000,SD 0.295),组间信度kappa为0.506(min 0.421,max 1.000,SD 0.167)。
关键数值与推荐
- 共识将超声领域从「炎症」和「损伤」修订为单一「肌肉炎症与损伤」领域,基本成分包括回声性和筋膜厚度。
临床怎么用
- 该共识定义的超声评分系统可用于IIM的肌肉炎症与损伤评估,但组间信度中等,需进一步优化和验证。
局限性
- 研究为初步数据,样本量和信度测试基于网络环境,组间信度仅中等。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
AIM: Current ultrasound grading tools do not fulfil the criteria of the OMERACT Filter 2.1 Instrument Selection Algorithm (OFISA)and are not idiopathic inflammatory myopathies (IIM)-specific, prompting further work by the OMERACT US Working Group. The aim of this study was, therefore, to develop consensual definitions of elementary US lesions specific to IIM, using a structured methodological approach. METHODS: A multicentre group of 21 international experts from the OMERACT US in myositis subgroup participated in a multi-round Delphi survey followed by a web-based reliability exercise. RESULTS: The group participated in five Delphi rounds, followed by a web-based reliability exercise. Preliminary broad domains of "inflammation" and "damage" resulted in substantial intra-rater reliability testing (kappa: 0.662 and 0.620, respectively) but poor inter-rater reliability testing (kappa: 0.142 and 0.112, respectively). A further two Delphi rounds resulted in a consensus to revise the broad domains to a single domain of "muscle inflammation and damage", with elementary components including echogenicity and fascial thickness. A categorical morphological grading system was then tested in a web-based reliability exercise, which resulted in substantial intra-rater reliability testing (kappa: 0.706, min: 0.051, max: 1.000, SD: 0.295) and an improved moderate inter-rater reliability testing (kappa: 0.506, min: 0.421, max: 1.000, SD: 0.167). CONCLUSION: The systematic approach by the OMERACT US in the myositis subgroup has developed a categorical morphological scoring system, which showed moderate inter-rater reliability using consensus-derived definitions of US domains in IIM.
引用
- Paramalingam S, Albayda J, Alfen NV, et al. A systematic approach to the consensus definitions and reliability of ultrasound in idiopathic inflammatory myopathies; Preliminary data by the OMERACT ultrasound in myositis working group. Semin Arthritis Rheum. 2026. PMID: 42034890. doi:10.1016/j.semarthrit.2026.152984
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。