DAPSA与DAPSA28在银屑病关节炎中的内部结构效度评估
基于EuroSpA网络1865例银屑病关节炎患者,采用验证性因子分析与心理测量学测试评估DAPSA和DAPSA28的内部结构效度。基线单维模型拟合可接受(RMSEA 0.020、0.034),但6个月随访拟合差(RMSEA 0.057、0.063),且存在性别与国家维度的项目功能差异,Cronbach's α分别为0.65和0.63。
要点
- DAPSA与DAPSA28基线单维CFA模型拟合可接受,支持内部结构效度。
- 6个月随访模型拟合差,基线与随访联合SEM未找到可接受模型。
- 存在性别与国家维度的DIF,且国家间异质性明显。
核心结论
- 总体模型拟合统计量可接受,支持DAPSA和DAPSA28的内部结构效度,但国家层面存在失拟证据。
- 内部一致性信度可接受,但性别与国家存在项目功能差异,需进一步研究这些及其他PsA疾病活动度测量工具。
研究设计与样本
- 欧洲脊柱关节炎研究协作网络(EuroSpA)观察性研究,纳入1865例有基线和随访DAPSA及DAPSA28评分的银屑病关节炎患者。
- 采用碎石图、验证性因子分析(CFA)和结构方程模型(SEM)评估内部结构效度,辅以项目功能差异(DIF)测试和Cronbach's α(CA)评估内部一致性信度;除描述性统计、相关矩阵和CA外,多数分析使用625例子集。
主要发现
- DAPSA和DAPSA28的单维CFA模型在基线拟合可接受(RMSEA分别为0.020和0.034)。
- 6个月随访时模型拟合差(RMSEA分别为0.057和0.063)。
- 结合基线与随访数据的SEM未能识别出可接受的模型拟合。
- 发现性别和国家维度的DIF,且观察到国家间异质性。
- Cronbach's α显示内部一致性可接受(DAPSA为0.65,DAPSA28为0.63)。
关键数值与推荐
- 基线单维CFA模型拟合:DAPSA的RMSEA为0.020,DAPSA28的RMSEA为0.034。
- 6个月随访模型拟合:DAPSA的RMSEA为0.057,DAPSA28的RMSEA为0.063。
- 内部一致性信度:DAPSA的Cronbach's α为0.65,DAPSA28的Cronbach's α为0.63。
临床怎么用
- DAPSA和DAPSA28在基线评估中具有可接受的内部结构效度和内部一致性,可用于PsA疾病活动度评估。
- 因存在性别和国家维度的DIF及随访期模型拟合不佳,跨性别、跨国比较或纵向追踪时需谨慎解读DAPSA/DAPSA28评分。
局限性
- 6个月随访时模型拟合差,基线与随访联合SEM未找到可接受模型。
- 存在性别和国家维度的DIF,国家间异质性明显。
- 多数分析仅使用625例子集,可能影响结果代表性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: The Disease Activity index for Psoriatic Arthritis (DAPSA) was developed to assess disease activity in patients with psoriatic arthritis (PsA). A modified version, DAPSA28, uses 28 joints instead of 66/68. This study evaluated key psychometric properties of DAPSA and DAPSA28. METHODS: Data from 1865 patients with PsA in the European Spondyloarthritis (EuroSpA) Research Collaboration Network, having DAPSA and DAPSA28 scores at baseline and follow-up, were analysed. Tests included assessment of internal construct validity by scree plots, confirmatory factor analysis (CFA) and structural equation modelling (SEM), supplemented by tests of differential item functioning (DIF) and evaluation of internal consistency reliability by Cronbach's α (CA). A subset of 625 patients was used for most analyses, except descriptive statistics, correlation matrix and CA. RESULTS: One-dimensional CFA models for DAPSA and DAPSA28 showed acceptable model fit at baseline (root mean square error of approximation, RMSEA: 0.020, 0.034). However, model fit at 6 months follow-up was poor (RMSEA: 0.057, 0.063). SEM combining baseline and follow-up data could not identify an acceptable model fit. DIF was found for sex and country. CA indicated acceptable internal consistency (DAPSA: 0.65; DAPSA28: 0.63). Heterogeneity across countries was observed. CONCLUSIONS: Overall, the model fit was acceptable across model fit statistics, supporting internal construct validity, but some evidence of misfit at country level was disclosed. Our findings support acceptable internal consistency reliability, but DIF was found for sex and country. Based on mixed results of model fit and DIF, further investigation of these and other PsA disease activity measures is warranted.
引用
- Jørgensen JB, Christensen KB, Michelsen B, et al. Assessing internal construct validity of DAPSA and DAPSA28 in psoriatic arthritis: a European observational study using confirmatory factor analysis and additional psychometric testing. RMD Open. 2025. PMID: 41436138. doi:10.1136/rmdopen-2025-006104
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。