文献速递脊柱关节炎

超声评估银屑病关节炎疾病活动度与结构损伤:意大利风湿病学会多中心UPsA评分研究

Ultrasound for assessing disease activity and structural damage in psoriatic arthritis: the UPsA scores from a multicentre study by the Italian Society of Rheumatology.
PubMed 文献 · Ann Rheum Dis · 2025-11-28

该研究基于19个意大利中心312例银屑病关节炎患者,开发并内部验证了UPsA活动评分和UPsA损伤评分,并衍生简化版sUPsA活动评分。UPsA活动评分与临床变量相关,对变化有中等敏感性,在达到最小疾病活动度患者中反应性高;sUPsA保留全评分90%信息并提高可行性。

要点

  • UPsA活动评分均值3.7(SD 1.86),与DAPSA(rs=0.42)、68压痛关节数(rs=0.31)、66肿胀关节数(rs=0.45)相关,均P<.001。
  • UPsA损伤评分均值4.1(SD 2.26),与改良Sharp-van der Heijde评分相关(rs=0.36,P<.001)。
  • UPsA活动评分总体敏感性中等(SRM=0.63),达到最小疾病活动度患者中反应性高(SRM=1.03)。

核心结论

  • UPsA评分经过内部验证并显示反应性,可作为评估银屑病关节炎活动度和损伤的有价值工具。

研究设计与样本

  • 基于19个意大利中心银屑病关节炎患者基线和6个月数据的多中心研究。
  • 超声评估覆盖42个关节、36条肌腱、12个附着点和2个滑囊,由受训超声医师完成。
  • 采用因子分析衍生复合评分(范围0-10),用Spearman相关评估结构效度,用标准化反应均值(SRM)评估敏感性。

主要发现

  • 共纳入312例银屑病关节炎患者。
  • UPsA活动评分均值3.7(SD 1.86),与DAPSA(rs=0.42)、68压痛关节数(rs=0.31)、66肿胀关节数(rs=0.45)相关,均P<.001。
  • UPsA损伤评分均值4.1(SD 2.26),与改良Sharp-van der Heijde评分相关(rs=0.36,P<.001)。
  • UPsA活动评分总体敏感性中等(SRM=0.63),达到最小疾病活动度患者中反应性高(SRM=1.03)。
  • sUPsA保留全评分90%的信息,同时大幅提高可行性。

关键数值与推荐

  • UPsA活动评分与DAPSA的相关系数rs=0.42(P<.001)。
  • UPsA活动评分与68压痛关节数的相关系数rs=0.31(P<.001)。
  • UPsA活动评分与66肿胀关节数的相关系数rs=0.45(P<.001)。
  • UPsA损伤评分与改良Sharp-van der Heijde评分的相关系数rs=0.36(P<.001)。
  • UPsA活动评分总体SRM=0.63,达到最小疾病活动度患者中SRM=1.03;sUPsA保留全评分90%信息。

临床怎么用

  • UPsA活动评分和损伤评分可用于评估银屑病关节炎的肌肉骨骼炎症和结构损伤。
  • sUPsA活动评分可提高常规临床实践中的可行性和适用性。

局限性

  • 原文未述局限性

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: As part of the ultrasound in psoriatic arthritis (PsA) treatment (Ultrasound in Psoriatic Arthritis Treatment-NCT03330769) study, 2 ultrasound scores for PsA (UPsA)-the UPsA activity score and the UPsA damage score-were developed and internally validated to assess musculoskeletal inflammation and structural damage in PsA. In addition, a simplified UPsA activity score (sUPsA) was also derived to enhance feasibility and applicability in routine clinical practice. METHODS: Baseline and 6-month data from patients with PsA across 19 Italian centres were analysed. Clinical evaluations included joint counts, enthesitis, dactylitis, and patient-reported outcomes. Ultrasound assessments, performed by trained sonographers, covered 42 joints, 36 tendons, 12 entheses, and 2 bursae. Factor analysis was used to derive composite scores (range 0-10). Construct validity was assessed by Spearman's correlations with clinical variables, and sensitivity to change was evaluated using the standardised response mean (SRM). RESULTS: A total of 312 patients with PsA were enrolled. The mean UPsA activity score was 3.7 (SD 1.86), correlating with Disease Activity for Psoriatic Arthritis (rs = 0.42), 68-tender joint count (rs = 0.31), and 66-swollen joint count (rs = 0.45; all P < .001). The UPsA damage score averaged 4.1 (SD 2.26), correlating with the modified Sharp-van der Heijde score (rs = 0.36, P < .001). The UPsA activity score showed moderate sensitivity to change overall (SRM = 0.63) and high responsiveness in patients achieving minimal disease activity (SRM = 1.03). The sUPsA retained 90% of the information from the full score while substantially improving feasibility. CONCLUSIONS: The UPsA scores underwent internal validation and demonstrated responsiveness, representing valuable tools to assess PsA activity and damage.

来源:Ann Rheum Dis,查看原文。版权归原作者所有。

引用

  1. Zabotti A, Piga M, Canzoni M, et al. Ultrasound for assessing disease activity and structural damage in psoriatic arthritis: the UPsA scores from a multicentre study by the Italian Society of Rheumatology. Ann Rheum Dis. 2025. PMID: 41314909. doi:10.1016/j.ard.2025.10.032

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。