文献速递类风湿关节炎

类风湿关节炎疾病活动度指标不一致性与定量感觉测试所测伤害可塑性疼痛的关联

Association Between Discordance of Disease Activity Indices and Quantitative Sensory Testing Measures of Nociplastic Pain in Patients With Rheumatoid Arthritis.
PubMed 文献 · Arthritis Care Res (Hoboken) · 2025-11-12

该横断面研究纳入225例活动性类风湿关节炎患者,评估三种疾病活动度不一致性指标与定量感觉测试所测伤害可塑性疼痛的关联。结果显示,压痛-肿胀关节数差值和DAS28-P与斜方肌压痛阈值降低及时间总和升高轻度相关,而患者整体评估减评估者整体评估与任何定量感觉测试指标均无关联。

要点

  • 压痛-肿胀关节数差值与斜方肌压痛阈值降低及时间总和升高相关。
  • DAS28-P与斜方肌压痛阈值降低及时间总和升高相关。
  • 患者整体评估减评估者整体评估与任何定量感觉测试指标均无关联。

核心结论

  • 所提出的三种不一致性指标中有两种(较高的压痛-肿胀关节数差值和DAS28-P)与更差的伤害可塑性疼痛定量感觉测试指标(较低的斜方肌压痛阈值和较高的时间总和)轻度相关,提示患者报告与医生评估的疾病活动度之间的不一致可能反映伤害可塑性疼痛的成分。

研究设计与样本

  • 横断面分析,纳入225例活动性类风湿关节炎患者,评估疾病活动度不一致性指标与定量感觉测试指标的关联,使用未校正和多变量线性回归模型。

主要发现

  • 压痛-肿胀关节数差值均值5.4(标准差±8.2),DAS28-P均值49.7%(标准差±13.3%),患者整体评估减评估者整体评估均值0.7(标准差±2.2)。
  • 较高的压痛-肿胀关节数差值与较低的斜方肌压痛阈值相关(β=-0.05;95%置信区间-0.08至-0.02),并与较高的时间总和相关(β=0.29;95%置信区间0.05至0.53)。
  • 较高的DAS28-P与较低的斜方肌压痛阈值相关(β=-0.05;95%置信区间-0.07至-0.04),并与较高的时间总和相关(β=0.21;95%置信区间0.06至0.35)。
  • 患者整体评估减评估者整体评估与任何定量感觉测试指标均无关联。

临床怎么用

  • 原文结论未据此给出临床推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: This study investigates the association between discordance in commonly collected clinical indicators of rheumatoid arthritis (RA) disease activity and abnormalities in quantitative sensory testing (QST) observed in individuals with nociplastic pain. The goal is to identify low-burden methods of assessing nociplastic pain in rheumatology practice. METHODS: Data from 225 patients with active RA were included for cross-sectional analyses. Measures of discordance in disease activity were as follows: (1) tender-swollen joint count difference (TSJD), (2) proportion of subjective components to the total Disease Activity Score in 28 joints (DAS28-P), and (3) patient global assessment of disease activity minus evaluator global assessment of Disease Activity (PtGA - EGA). QST measures were pressure pain thresholds (PPTs) at the trapezius, temporal summation (TS), and conditioned pain modulation. We evaluated associations between measures of discordance and QST using unadjusted and multivariable linear regression models. RESULTS: The mean TSJD was 5.4 (SD ±8.2), and the mean DAS28-P was 49.7% (SD ±13.3%). The mean PtGA - EGA was 0.7 (SD ±2.2). Higher TSJD was associated with lower trapezius PPT (β = -0.05; 95% confidence interval [CI] -0.08 to -0.02) and higher TS (β = 0.29; 95% CI 0.05 to 0.53). Higher DAS28-P was associated with a lower trapezius PPT (β = -0.05; 95% CI -0.07 to -0.04) and higher TS (β = 0.21; 95% CI 0.06 to 0.35). PtGA - EGA was not associated with any QST measures. CONCLUSION: Two of our proposed measures of discordance (higher TSJD and DAS28-P) were modestly associated with worse QST measures of nociplastic pain (lower trapezius PPT and higher TS), suggesting that discordance between patient-reported and physician-assessed measures of disease activity may reflect an element of nociplastic pain.

来源:Arthritis Care Res (Hoboken),查看原文。版权归原作者所有。

引用

  1. Lin CP, Aydemir B, Song J, et al. Association Between Discordance of Disease Activity Indices and Quantitative Sensory Testing Measures of Nociplastic Pain in Patients With Rheumatoid Arthritis. Arthritis Care Res (Hoboken). 2025. PMID: 41098035. doi:10.1002/acr.25668

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。