文献速递脊柱关节炎

光学光谱透射评估银屑病关节炎炎症:与临床指标及超声的相关性

Inflammation assessment in psoriatic arthritis via optical spectral transmission: correlations with clinical markers and musculoskeletal ultrasound.
PubMed 文献 · Rheumatology (Oxford) · 2026-01-01

研究纳入100例银屑病关节炎患者与100名健康对照,各评估3000个指关节及腕关节,发现OST在患者组显著高于对照组(15.76 vs 10.24;p<0.001),ROC曲线下面积0.848(95%CI 0.795-0.900;p<0.001),截断值12.75时灵敏度0.89、特异度0.71。OST与关节能量多普勒超声(rho=0.412;p=0.015)、灰阶超声(rho=0.419;p=0.014)、CRP(rho=0.232;p=0.021)、DAPSA(rho=0.215;p=0.032)及DAS28(rho=0.23;p=0.021)呈中度相关。

要点

  • OST在PsA患者组显著高于健康对照组(15.76 vs 10.24;p<0.001)。
  • OST诊断PsA的AUC为0.848(95%CI 0.795-0.900),截断值12.75时灵敏度0.89、特异度0.71。
  • OST与超声及临床活动度指标呈中度相关(rho 0.215-0.419)。

核心结论

  • OST与PsA患者的临床、超声及实验室疾病活动度指标显著相关。
  • OST能可靠区分PsA患者中超声证实的炎症关节与非炎症关节。

研究设计与样本

  • 对100例PsA患者和100名健康对照的手指(掌指、近端指间、远端指间)及腕关节行OST和临床检查,共各3000个关节。
  • 部分患者额外接受肌骨超声检查;采用ROC评估OST诊断效能,通过相关分析和线性回归检验OST值与临床、实验室及超声活动度指标的关联。

主要发现

  • PsA组OST显著高于对照组(15.76 vs 10.24;p<0.001)。
  • ROC分析(PsA vs 对照)显示AUC为0.848(95%CI 0.795-0.900;p<0.001),截断值12.75时灵敏度0.89、特异度0.71。
  • 患者中OST与关节能量多普勒超声相关(rho=0.412;p=0.015),与灰阶超声相关(rho=0.419;p=0.014)。
  • OST与CRP相关(rho=0.232;p=0.021),与DAPSA相关(rho=0.215;p=0.032),与DAS28相关(rho=0.23;p=0.021)。

关键数值与推荐

  • OST诊断PsA的AUC为0.848(95%CI 0.795-0.900;p<0.001)。
  • OST截断值12.75时,灵敏度0.89、特异度0.71。
  • OST与关节能量多普勒超声rho=0.412(p=0.015),与灰阶超声rho=0.419(p=0.014)。
  • OST与CRP rho=0.232(p=0.021),与DAPSA rho=0.215(p=0.032),与DAS28 rho=0.23(p=0.021)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To assess the value of optical spectral transmission (OST) in detecting joint inflammation in patients with psoriatic arthritis (PsA) and to evaluate correlations of OST with musculoskeletal ultrasound (US) and clinical disease activity markers. METHODS: OST and clinical examinations were performed on the finger (metacarpophalangeal, proximal-interphalangeal, distal-interphalangeal) and wrist joints of patients with PsA and healthy controls. A subset of patients was additionally examined via musculoskeletal US. OST differences in the two groups were statistically assessed and the diagnostic performance of OST was evaluated by Receiver-Operating-Characteristics (ROC). Additionally, associations between OST values and clinical, laboratory, as well as US activity markers were examined through correlation analyses and linear regression. RESULTS: A total of 3,000 joints from 100 PsA patients were examined using OST and compared to 3,000 joints from 100 controls. OST was significantly higher in the PsA group compared to the control group (15.76 vs. 10.24; p<0.001). ROC (PsA vs. controls) revealed a very good diagnostic OST performance by an area-under-the-curve of 0.848 (95%-CI 0.795-0.900; p<0.001), with a sensitivity of 0.89 and specificity of 0.71 for an OST cut-off of 12.75. Among patients, OST correlated moderately with Joint-Power-Doppler- (rho=0.412; p=0.015) and Grey-Scale-US (rho=0.419; p=0.014), respectively. Moreover, significant OST correlations with CRP (rho=0.232; p=0.021), ''Disease-Activity-in-Psoriatic-Arthritis (DAPSA)'' (rho=0.215; p=0.032) and "Disease-Activity-Score-28 (DAS28)" (rho=0.23; p=0.021) were found. CONCLUSION: OST associated significantly with clinical, US and laboratory disease activity markers in patients with PsA. Furthermore, OST could reliably differentiate between sonographically inflamed and non-inflamed joints in patients with PsA.

来源:Rheumatology (Oxford),查看原文。版权归原作者所有。

引用

  1. Triantafyllias K, Liverakos S, Baraliakos X, et al. Inflammation assessment in psoriatic arthritis via optical spectral transmission: correlations with clinical markers and musculoskeletal ultrasound. Rheumatology (Oxford). 2026. PMID: 40994419. doi:10.1093/rheumatology/keaf480

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。