文献速递其他结缔组织病

特发性炎性肌病患者在家庭与诊室环境中进行坐立试验、计时起立行走试验和六分钟步行试验的表现

Performance of sit-to-stand, timed up-and-go, and six-minute walk tests in home and office settings in patients with idiopathic inflammatory myopathy.
PubMed 文献 · Semin Arthritis Rheum · 2025-08-12

前瞻性纳入50例特发性炎性肌病成人患者,在0、3、6个月于诊室完成坐立试验、计时起立行走试验和六分钟步行距离,并在访视后14天内于家中自测。坐立试验与计时起立行走试验在两种环境下重测信度良好且表现相近,六分钟步行距离在诊室显著更高、居家自测信度差;三项试验均可区分疾病活动与非活动,并与患者中心结局相关。

要点

  • 坐立试验和计时起立行走试验在诊室与家庭环境中表现相近,重测信度强。
  • 六分钟步行距离在诊室显著高于家庭环境,居家自测信度差。
  • 三项功能试验均可区分疾病活动与非活动,并与身体功能、生活质量及体力活动相关。

核心结论

  • 坐立试验、计时起立行走试验和六分钟步行距离具有良好的重测信度、效度和反应性。
  • 六分钟步行距离在家庭自测时信度差,而坐立试验和计时起立行走试验在诊室与家庭环境中表现相似。

研究设计与样本

  • 前瞻性研究纳入50例特发性炎性肌病成人患者,平均年龄51.6岁,女性占60%。
  • 患者在0、3、6个月于诊室完成坐立试验、计时起立行走试验和六分钟步行距离,并在访视后14天内于家中自测。
  • 分别有24例、23例和20例完成居家坐立试验、计时起立行走试验和六分钟步行距离。
  • 采用斯皮尔曼相关、效应量、标准化反应均值和回归模型评估功能试验与其他测量指标的横断面和纵向关联。

主要发现

  • 坐立试验和计时起立行走试验在家庭和诊室环境中均显示强重测信度。
  • 六分钟步行距离在诊室环境中显著更高,而计时起立行走试验和坐立试验在家庭与诊室间相当。
  • 三项功能试验均能显著区分疾病活动与非活动,并与身体功能、生活质量和体力活动的患者中心结局指标有显著横断面和纵向关联。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Patients with idiopathic inflammatory myopathies (IIM) frequently experience limitations in their physical function. Sit-to-stand (STS), timed-up-and-go (TUG), and six-minute walk distance (6MWD) are task-oriented functional tests that can provide objective information about physical function. In this study, we assess their measurement properties in office and home settings. METHODS: Adults with IIM were enrolled in a prospective study. Patients performed the functional tests (STS, TUG, 6MWD) at 0-, 3- and 6-months, and self-performed these tests at home within 14-days of the visit. Several patient centered outcome measures (PCOMs) were obtained: fatigue (visual analog scale [VAS]), pain (VAS), quality of life (SF-36), physical function (PROMIS, SF36), and physical activity (Actigraphy). Spearman correlation, effect size, standardized response mean, and regression models were used to assess cross-sectional and longitudinal association between functional tests and other measures. RESULTS: Fifty patients (mean age 51.6, 60% female) were enrolled. Twenty-four, 23, and 20 completed at-home STS, TUG, and 6MWD, respectively. STS and TUG showed strong test-retest reliability at both home and office settings. 6MWD was significantly higher at office setting, whereas TUG/STS was comparable between home and office. All three functional tests significantly discriminated between active vs inactive disease and had significant cross sectional and longitudinal association with PCOMs of physical function, quality of life, and physical activity. CONCLUSION: STS, TUG and 6MWD have good test-retest reliability, validity and responsiveness. 6MWD has poor reliability when self-performed at home, while STS/TUG perform similarly in the office and home settings.

来源:Semin Arthritis Rheum,查看原文。版权归原作者所有。

引用

  1. Saygin D, Pillai AC, Wakeley AK, et al. Performance of sit-to-stand, timed up-and-go, and six-minute walk tests in home and office settings in patients with idiopathic inflammatory myopathy. Semin Arthritis Rheum. 2025. PMID: 40834494. doi:10.1016/j.semarthrit.2025.152809

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。