高频超声评估泪腺对原发性干燥病的诊断价值
该研究纳入疑似原发性干燥病(pSjD)患者,行唾液腺超声(SGUS)和泪腺超声(LGUS)检查,并以美国风湿病学会/EULAR分类标准诊断。LGUS诊断pSjD的敏感度为61.5%、特异度为87.5%,优于SGUS;LGUS与SSA(OR 17.4)及SSB(OR 23.0)显著相关,与Schirmer试验阳性无显著关联。
要点
- LGUS诊断pSjD的敏感度为61.5%、特异度为87.5%,PPV 80.0%、NPV 73.3%。
- LGUS与SSA(OR 17.4,p=0.005)及SSB(OR 23.0,p=0.003)显著相关。
- LGUS与Schirmer试验阳性无统计学显著关联(p=0.86)。
核心结论
- LGUS对pSjD诊断具有中等敏感度和高特异度。
- OMERACT评分系统以≥2分为切点似乎适用于泪腺病理评分,可能作为pSjD诊断评估的有价值补充工具。
研究设计与样本
- 纳入疑似pSjD患者,均行唾液腺超声(SGUS)和泪腺超声(LGUS)检查,并完成非刺激唾液流率、Schirmer试验和实验室检查(包括自身抗体)。
- 共纳入30例患者,1例因数据缺失被排除,13例根据美国风湿病学会/EULAR分类标准诊断为pSjD。
- 超声检查采用GE Logiq E10设备,SGUS使用4-20 MHz线阵探头,LGUS使用6-24 MHz曲棍球棒探头。
- 所有腺体采用OMERACT共识灰阶评分系统(0-3分),评分≥2分视为病理。
主要发现
- LGUS诊断pSjD的敏感度为61.5%、特异度为87.5%,PPV为80.0%、NPV为73.3%,在当前队列中优于SGUS。
- LGUS与Schirmer试验阳性无统计学显著关联(p=0.86)。
- LGUS与SSA显著相关(OR 17.4,p=0.005),与SSB显著相关(OR 23.0,p=0.003)。
关键数值与推荐
- pSjD诊断依据美国风湿病学会/EULAR分类标准。
- OMERACT共识灰阶评分系统(0-3分)用于所有腺体,评分≥2分视为病理。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: The aim of the study was to evaluate the ultrasound findings in lacrimal glands in a cohort of patients with suspected primary Sjögren's disease (pSjD) and to assess the relationship with the diagnosis and the association with functional tests and autoantibodies. METHODS: Patients with suspected pSjD, evaluated by salivary gland ultrasound (SGUS) and lacrimal gland (LGUS) as part of the diagnostic set-up were included. All had unstimulated sialometry, Schirmer's test and laboratory test done (including autoantibodies). Ultrasound examination was performed with a GE Logiq E10 (a linear 4-20 MHz transducer for SGUS and a 6-24 MHz hockey stick transducer for LGUS). The OMERACT consensus-based greyscale scoring system (0-3) for salivary glands was applied for all glands. A score of ≥2 was considered pathological. RESULTS: 30 patients were included, one was subsequently excluded due to missing data, 13 were diagnosed with pSjD according to the American College of Rheumatology/EULAR classification criteria. The sensitivity and specificity for LGUS for pSJD diagnosis were 61.5 and 87.5, respectively. The PPV and NPV values were 80.0 and 73.3, respectively-better than SGUS for the current cohort. There was no statistically significant association between LGUS and Schirmer's test positivity (p value: 0.86), but there was a significant association between LGUS and SSA (OR: 17.4, p=0.005) as well as SSB (OR: 23.0, p=0.003). CONCLUSION: LGUS has moderate sensitivity and high specificity for the diagnosis of pSjD. The OMERACT scoring system appears relevant for scoring pathology in the lacrimal glands using grade ≥2 as cut-off and may be a valuable supplementary tool for diagnostic evaluation in pSjD.
引用
- Terslev L, Schmidt NS, Ammitzbøll-Danielsen M, et al. Diagnostic value of high-frequency ultrasound assessment of the lacrimal glands for primary Sjögren's disease. RMD Open. 2025. PMID: 40592723. doi:10.1136/rmdopen-2025-005884
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。