文献速递其他结缔组织病

系统性硬化症与炎性肌病中间质性肺病肺部超声判读标准的验证

Validation of Lung Ultrasound Interpretation Criteria for Interstitial Lung Disease in Systemic Sclerosis and Inflammatory Myopathy.
PubMed 文献 · Arthritis Care Res (Hoboken) · 2025-06-22

本研究在95例系统性硬化症(SSc)和炎性肌病(IM)患者中验证修订版肺部超声间质性肺病判读标准(LUS-ILD-24),以胸部CT为参照。各判读者间敏感性92.4%~95.5%、特异性82.8%~86.2%,判读者间信度κ=0.92,判读者内信度κ=0.90~1。LUS严重度与CT严重度相关,并与一氧化碳弥散量和用力肺活量呈负相关。

要点

  • LUS-ILD-24在SSc和IM患者中检测CT所示ILD的敏感性92.4%~95.5%、特异性82.8%~86.2%。
  • 判读者间信度κ=0.92,判读者内信度κ=0.90~1,接近完全一致。
  • LUS严重度与CT严重度相关,与一氧化碳弥散量和用力肺活量呈负相关。

核心结论

  • 修订版LUS-ILD-24在SSc和IM队列中得到验证,对CT所识别ILD具有优良的敏感性、特异性和信度。
  • LUS严重度与CT及肺功能指标所示的ILD严重度相关。
  • 修订版LUS-ILD-24的验证支持将肺部超声纳入SSc和IM患者ILD的筛查流程。

研究设计与样本

  • 本研究为诊断准确性验证研究,纳入符合SSc和IM标准且计划行胸部CT的患者,共95例纳入分析。
  • 患者接受肺部超声检查,由三名盲法判读者按LUS-ILD-24判读,并与CT所见ILD比较。
  • 分析SSc、IM及可能新发ILD亚组的敏感性与特异性,计算判读者间和判读者内一致性,并评估LUS-ILD-24严重度与CT严重度及肺功能检查的相关性。

主要发现

  • 各判读者检测ILD的敏感性为92.4%~95.5%,特异性为82.8%~86.2%。
  • 各亚组准确性相似。
  • 判读者间信度κ=0.92,判读者内信度κ=0.90~1,接近完全一致。
  • LUS严重度与CT影像严重度相关,与一氧化碳弥散量和用力肺活量呈负相关。

关键数值与推荐

  • LUS-ILD-24为2020年开发的LUS-ILD-20的修订版,本研究对其进行验证。
  • 各判读者检测ILD的敏感性92.4%~95.5%、特异性82.8%~86.2%。
  • 判读者间信度κ=0.92,判读者内信度κ=0.90~1。

临床怎么用

  • 作者结论认为,修订版LUS-ILD-24的验证支持将肺部超声纳入SSc和IM患者ILD的筛查流程。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: Interstitial lung disease (ILD) has a high prevalence in patients with systemic sclerosis (SSc) and inflammatory myopathy (IM), and early identification reduces associated morbidity and mortality. We previously developed lung ultrasound (LUS) interpretation criteria for ILD detection in 2020 (LUS-ILD-20) showing excellent sensitivity and specificity in patients with SSc-ILD; herein, we sought to validate a revised LUS-ILD-24 in a large cohort with SSc and IM. METHODS: Patients meeting criteria for SSc and IM, with planned computed tomography (CT) chest imaging underwent LUS imaging interpreted with LUS-ILD-24 by three blinded readers. The sensitivity and specificity for LUS-ILD detection as noted on CT was analyzed for subgroups with SSc, IM, and possible incident ILD. Inter- and intrarater agreements were calculated. Correlations between LUS-ILD-24 severity, CT imaging severity, and pulmonary function tests were assessed. RESULTS: Ninety-five patients were included in the analyses. Sensitivity and specificity for ILD detection ranged from 92.4% to 95.5% and 82.8% to 86.2% across readers with similar accuracy in all subgroups. Inter- and intrareader reliability showed near perfect agreement (κ = 0.92 and κ = 0.90 to 1, respectively). LUS severity correlated with CT imaging severity and inversely correlated with diffusion capacity for carbon monoxide and forced vital capacity. CONCLUSION: We validated our revised LUS-ILD-24 in cohorts with SSc and IM and found excellent sensitivity, specificity, and reliability for detection of ILD identified on CT imaging. LUS severity correlated with CT and pulmonary function test markers of ILD severity. Validation of the revised LUS-ILD-24 supports the implementation of LUS imaging in screening algorithms for ILD in patients with SSc and IM.

来源:Arthritis Care Res (Hoboken),查看原文。版权归原作者所有。

引用

  1. Fairchild RM, Mar DA, Deluna MD, et al. Validation of Lung Ultrasound Interpretation Criteria for Interstitial Lung Disease in Systemic Sclerosis and Inflammatory Myopathy. Arthritis Care Res (Hoboken). 2025. PMID: 40320831. doi:10.1002/acr.25567

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。