压缩比:一种量化可压缩性以诊断巨细胞动脉炎的新方法
该横断面研究测量未压缩与压缩动脉的横截面积并计算压缩比(CR),比较304例患者中巨细胞动脉炎(GCA)组与非GCA组的CR值及诊断性能,发现GCA组CR值显著低于非GCA组,提出预测GCA的CR阈值≤2.3。
要点
- GCA组CR值无论按患者均值还是最低值比较均显著低于非GCA组(Mann-Whitney U检验P<0.001)。
- 研究提示预测GCA诊断的CR阈值为≤2.3。
- CR是一种可量化的新指标,可能有助于声像图医师确认晕征并提高超声评估GCA的客观性。
核心结论
- 压缩比(CR)是一种有助于超声评估GCA的新型可量化指标,值得进一步研究,在临床应用中可能提高诊断确定性。
研究设计与样本
- 横断面研究,纳入304例患者(65.8%为女性),超声测量未压缩与压缩动脉的横截面积并计算压缩比(CR),分为GCA组(n=72)与非GCA组(n=232)。
主要发现
- GCA组CR值无论按个体患者均值还是最低CR值比较均显著低于非GCA组(Mann-Whitney U检验P<0.001)。
- 本研究由单一熟练临床医师观察到的CR值提示预测GCA诊断的CR阈值为≤2.3。
关键数值与推荐
- 预测GCA诊断的CR阈值为≤2.3,该阈值来自单一熟练临床医师的观察。
- 诊断性能与晕征计数(HC)进行比较。
临床怎么用
- 原文未据此给出推荐。
局限性
- CR阈值来自单一熟练临床医师的观察,需在其他研究中确认。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: Ultrasonographic assessment of giant cell arteritis (GCA) relies on the demonstration of a non-compressible halo. Several ultrasonographic methods have been developed to quantify arterial wall thickness; however, arterial compressibility has not been quantified. This study presents a possible solution for quantifying compressibility to assist in diagnosing GCA. METHODS: Cross-sectional areas of uncompressed and compressed arteries were measured ultrasonographically, and their ratio was calculated [compression ratio (CR)]. The values obtained were tested for a relationship with the diagnosis of GCA and diagnostic performance was compared against halo count (HC). RESULTS: Ultrasound findings from 304 patients (65.8% females) were divided into GCA arm (n = 72) and Not-GCA arm (n = 232). The CR values for patients in the GCA arm were significantly lower than the Not-GCA arm whether compared as the individual patient mean or lowest CR value (Mann-Whitney U test P <0.001). The CR values observed in this study from a single skilled clinician suggest a threshold CR value of ≤2.3 for predicting a diagnosis of GCA. If confirmed in other studies this would effectively provide a quantitative measure that might help training sonographers confirm a visually identified halo sign and enhance objectivity in ultrasonographic assessment of GCA. CONCLUSION: Compression ratio (CR) is a novel quantifiable measure that contributes to the ultrasound assessment of GCA. It is worthy of further research and in clinical application, it is a measurement that may enhance diagnostic certainty.
引用
- Khurshid MA, Mynors-Wallis D, Richards S, et al. Compression ratio: a novel method to quantify compressibility as a diagnostic measurement in giant cell arteritis. Rheumatology (Oxford). 2025. PMID: 39666945. doi:10.1093/rheumatology/keae674
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。