手和足常规X线摄影在临床疑似关节痛患者中无诊断或预后价值:一项大型纵向研究
该研究基于Leiden临床疑似关节痛(CSA)队列,纳入749例有症状关节痛患者,分析1497份手和足X线片。基线时放射学侵蚀性疾病罕见(放射科医师判读1.7%,ACR/EULAR标准2.5%),随访中无患者SHS侵蚀评分进展≥5分,且基线侵蚀性疾病与炎症性关节炎(IA)发生无关(HR 0.98,95%CI 0.40-2.44)。结论认为在关节痛高危阶段可省略常规手和足X线检查。
要点
- 基线时放射学侵蚀性疾病罕见:放射科医师判读1.7%,ACR/EULAR标准2.5%。
- 随访期间无患者SHS侵蚀评分进展≥5分。
- 基线侵蚀性疾病与IA发生无关(HR 0.98,95%CI 0.40-2.44)。
核心结论
- 在CSA起病时,放射学侵蚀性疾病罕见,且在CSA阶段很少进展,对IA发生无预测价值。
- 因此,临床实践中在关节痛高危阶段可省略常规手和足X线检查(如同RA诊断时常规所做)。
研究设计与样本
- 研究纳入Leiden CSA队列中有症状关节痛的患者,随访2年或直至发生炎症性关节炎(IA)。
- 共分析749例患者的1497份手和足X线片,采用Sharp van der Heijde评分法(SHS)评估系列影像。
- 侵蚀性疾病分别按放射科医师判读或ACR/EULAR 2010 RA标准中的RA特异性侵蚀定义判定。
- 分析按抗瓜氨酸化蛋白抗体状态分层,并评估基线侵蚀性疾病与IA发生的关联。
主要发现
- 基线SHS侵蚀评分中位数为0(IQR 0-1)。
- 按放射科医师判读,RA特异性侵蚀性疾病占1.7%;按ACR/EULAR标准占2.5%。
- 随访期间无CSA患者SHS侵蚀评分进展≥5分。
- 基线侵蚀性疾病与IA发生无关(HR 0.98,95%CI 0.40-2.44)。
关键数值与推荐
- 侵蚀性疾病定义:放射科医师判读或ACR/EULAR 2010 RA标准中的RA特异性侵蚀定义。
- 影像学评估采用Sharp van der Heijde评分法(SHS),进展定义为SHS侵蚀评分进展≥5分。
- RA特异性侵蚀性疾病患病率:放射科医师判读1.7%,ACR/EULAR标准2.5%。
- 基线侵蚀性疾病与IA发生的HR为0.98(95%CI 0.40-2.44)。
临床怎么用
- 作者认为,对于临床疑似关节痛(CSA)患者,在关节痛高危阶段可省略常规手和足X线检查(如同RA诊断时常规所做)。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND: Conventional radiographs of hands and feet are used to depict structural damage in rheumatoid arthritis (RA). This is also commonly done in clinical practice in symptomatic patients at risk for RA (clinically suspect arthralgia (CSA)), but its rationale is unclear. We aimed to investigate the prevalence of radiographic erosive disease in patients with CSA and its progression over time. METHODS: Patients with symptomatic arthralgia of the Leiden CSA cohort were studied during 2-year follow-up or until development of inflammatory arthritis (IA). Erosive disease was defined according to the radiologist, or according to the RA-specific erosive definition in light of the American College of Rheumatology (ACR)/European Alliance of Associations for Rheumatology (EULAR) 2010 RA criteria. Serial radiographs were evaluated according to the Sharp van der Heijde Scoring method (SHS) and radiographic erosive progression was determined. Additionally, it was evaluated if baseline erosive disease associated with IA development. Analyses were stratified for anticitrullinated protein antibody status. RESULTS: 1497 radiographs of hands and feet of 749 patients with CSA were studied. Median SHS-erosion score at baseline was 0 (IQR 0-1). RA-specific erosive disease was present in 1.7% according to the radiologist, and 2.5% according to the ACR/EULAR criteria. No patients with CSA progressed ≥5 SHS-erosion points during follow-up. Erosive disease at CSA onset was not associated with IA development (HR 0.98 (95% CI 0.40 to 2.44)). CONCLUSIONS: At CSA onset, radiographic erosive disease is rare. In addition, it is rarely progressive within the CSA phase and not predictive for IA development. Therefore, for clinical practice, routinely made radiographs of hands and feet (such as regularly done at RA diagnosis) can be omitted in the at-risk stage of arthralgia.
引用
- Dumoulin QA, van der Helm-van Mil AHM, van Steenbergen HW, et al. Routine radiographs of hands and feet do not have diagnostic or prognostic value in patients with clinically suspect arthralgia: a large longitudinal study. RMD Open. 2024. PMID: 39537207. doi:10.1136/rmdopen-2024-004966
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。