不同超声扫描定义下无症状高尿酸血症中晶体沉积的患病率:一项比较研究
77例无症状高尿酸血症(血清尿酸≥7 mg/dL)患者接受10个部位肌肉骨骼超声检查,评估OMERACT痛风基本病变。不同定义下晶体沉积率从23.4%至87.0%不等,部分定义能更好区分伴随炎症,各方案间骨侵蚀及临床实验室变量相似。
要点
- 无症状高尿酸血症中超声晶体沉积率因扫描定义不同而差异显著,范围为23.4%至87.0%。
- 19.5%的患者存在阳性能量多普勒信号,28.4%存在骨侵蚀。
- 需要验证的、基于共识的定义来统一无症状高尿酸血症的超声评估。
核心结论
- 无症状高尿酸血症中超声沉积率在不同方案间差异巨大,部分方案可区分伴随炎症,均强调需要验证的、基于共识的定义。
研究设计与样本
- 77例无症状高尿酸血症(血清尿酸≥7 mg/dL)患者接受10个部位肌肉骨骼超声检查,评估OMERACT痛风基本病变(双轨征、痛风石、聚集物)。
主要发现
- 患者中位1个部位(IQR 0-2)有痛风石,1个部位(IQR 1-2)有聚集物,0个部位(IQR 0-1)有双轨征。
- 沉积率范围为23.4%(>1个部位有2-3级双轨征或痛风石)至87.0%(全部10个部位任何沉积)。
- 19.5%的患者有阳性能量多普勒信号,28.4%有骨侵蚀。
- 需要2-3级或>1个部位病变的标准能更好区分阳性能量多普勒信号。
- 骨侵蚀及不同临床和实验室变量在各方案间相似。
关键数值与推荐
- 不同定义包括:任何沉积;仅双轨征和/或痛风石;任何级别;仅2-3级沉积;10个部位;4关节方案(膝和第一跖趾关节);>1个部位有沉积;预设定义(股骨髁/第一跖趾关节双轨征和/或第一跖趾关节痛风石)。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
BACKGROUND/AIM: The appropriate sonographic protocol for assessing urate crystal deposits in asymptomatic hyperuricemia (AH) is undefined, as well as how the choice would impact on deposit rates and accompanying sonographic, clinical and laboratory features. METHODS: Patients with AH (serum urate ≥7 mg/dL) underwent musculoskeletal ultrasound of 10 locations for OMERACT elementary gout lesions (double contour [DC] signs, tophi, aggregates). Different definitions for AH with deposits were applied, varying according to deposits (any deposits; only DC and/or tophi); gradation (any grade; only grade 2-3 deposits), location (10 locations; 4-joint scheme including knees and 1MTPs; >1 location with deposits), or pre-defined definitions (DC sign in femoral condyles/1MTP and/or tophi in 1MTP). We evaluated crystal deposits rates and compared between other sonographic features, clinical and laboratory variables. RESULTS: Seventy-seven participants with AH showed a median 1 location (IQR 0-2) with tophi, 1 (IQR 1-2) with aggregates, and 0 locations (IQR 0-1) with DC sign. The deposition rate ranged from 23.4% (in >1 location with grade 2-3 DC or tophi) to 87.0% (in any deposit in all 10 locations). Accompanying inflammation - assessed by a positive power-Doppler (PD) signal - and erosions were found in 19.5% and 28.4% of participants, respectively. Positive PD signal was better discriminated by criteria requiring grade 2-3 or >1 location with lesions. Erosions and the different clinical and laboratory variables were similar among protocols. CONCLUSION: Rates of sonographic deposition in AH varied dramatically among studied protocols, while some could discriminate accompanying inflammation, all highlighting the need for a validated, consensus-based definition.
引用
- Peral-Garrido ML, Gómez-Sabater S, Caño R, et al. Prevalence of crystal deposits in asymptomatic hyperuricemia according to different scanning definitions: A comparative study. Semin Arthritis Rheum. 2024. PMID: 38924926. doi:10.1016/j.semarthrit.2024.152470
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。