类风湿关节炎中高分辨率外周定量计算机断层扫描与常规放射学评估侵蚀进展的比较
这项前瞻性研究纳入359例病程≥5年的类风湿关节炎患者,在基线和1年后分别用高分辨率外周定量计算机断层扫描(HR-pQCT)和常规放射学(CR)评估侵蚀进展。配对分析(n=310)中,CR识别30例进展,HR-pQCT识别40例,其中33例CR未识别;联合HR-pQCT使识别进展的患者比例从10%增至20%。以CR为参考,HR-pQCT识别侵蚀进展的敏感性为23.3%(95%CI:9.9,42.3%),特异性为88.2%(95%CI:83.8,91.7%)。
要点
- 仅用CR监测会漏诊相当比例有侵蚀进展的RA患者。
- HR-pQCT联合CR使识别进展患者比例从10%增至20%。
- 以CR为参考,HR-pQCT敏感性23.3%,特异性88.2%。
核心结论
- 仅用CR监测侵蚀进展会漏诊相当比例有侵蚀进展的患者。
- 在CR基础上加做高分辨率外周CT可使可能从针对侵蚀进展的个体化治疗中获益的患者比例翻倍。
研究设计与样本
- 前瞻性研究,纳入359例病程≥5年的类风湿关节炎患者,入组时间为2018年3月至2020年10月。
- 基线和1年后分别获取HR-pQCT和CR,HR-pQCT在优势手两个掌指关节评估侵蚀,CR采用Sharp/van der Heijde评分评估手、腕和足。
- HR-pQCT进展定义为侵蚀数目增加≥1或侵蚀体积增加超过最小显著变化;CR进展定义为侵蚀评分增加1.1分(依据最小可检测变化)。
主要发现
- 配对分析(n=310)中,CR识别30例侵蚀进展,HR-pQCT识别40例。
- HR-pQCT识别的40例进展患者中,33例CR未识别。
- 联合HR-pQCT后识别进展的患者比例从30例(10%)增至63例(20%)。
- 以CR为参考,HR-pQCT识别侵蚀进展的敏感性为23.3%(95%CI:9.9,42.3%),特异性为88.2%(95%CI:83.8,91.7%)。
关键数值与推荐
- HR-pQCT侵蚀进展定义:侵蚀数目增加≥1或侵蚀体积增加超过最小显著变化。
- CR侵蚀进展定义:侵蚀评分增加1.1分(依据最小可检测变化)。
- 以CR为参考,HR-pQCT敏感性23.3%(95%CI:9.9,42.3%),特异性88.2%(95%CI:83.8,91.7%)。
临床怎么用
- 原文结论未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: To investigate the diagnostic accuracy of high-resolution peripheral quantitative computed tomography (HR-pQCT) to assess erosive progression during 1 year compared with conventional radiography (CR) in rheumatoid arthritis (RA). METHODS: This prospective study included 359 patients with RA (disease duration ≥5 years) between March 2018 and October 2020. HR-pQCT and CR were obtained at inclusion and after 1 year. Erosive assessment was performed at two metacarpophalangeal joints of the dominant hand using HR-pQCT, and progression was defined as an increase in erosion number ≥1 or an increase in erosive volume > least significant change. CR of hands, wrists and feet was evaluated using Sharp/van der Heijde scores and erosive progression was defined as a 1.1-point increase in erosion score according to the smallest detectable change. RESULTS: In paired analyses (n = 310), erosive progression was identified in 30 patients using CR and in 40 patients using HR-pQCT. In the 40 patients with erosive progression on HR-pQCT, progression was not identified by CR in 33 patients. Adding HR-pQCT to CR doubled the proportion of patients identified with progression from 30 (10%) to 63 (20%) patients. Using CR as the reference, the sensitivity of HR-pQCT for identifying erosive progression was 23.3% (95% CI: 9.9, 42.3%) and the specificity was 88.2% (95% CI: 83.8, 91.7%). CONCLUSION: A substantial proportion of patients with erosive progression are overlooked using CR only to monitor erosive progression. Adding high-resolution peripheral CT to CR doubles the proportion of patients who may benefit from individualized therapy targeting erosive progression in RA.
引用
- Therkildsen J, Klose-Jensen R, Hänel M, et al. Erosive progression by high-resolution peripheral quantitative computed tomography and conventional radiography in rheumatoid arthritis. Rheumatology (Oxford). 2025. PMID: 38749001. doi:10.1093/rheumatology/keae281
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。