文献速递痛风与晶体性关节病

拉曼光谱联合偏振光显微镜对焦磷酸钙相关关节炎的诊断准确性

Diagnostic Accuracy of Raman Spectroscopy Integrated With Polarized Light Microscopy for Calcium Pyrophosphate-Associated Arthritis.
PubMed 文献 · Arthritis Care Res (Hoboken) · 2024-05-07

在荷兰一家医院连续纳入400份滑液样本,评估整合拉曼偏振光显微镜(iRPolM)识别焦磷酸钙(CPP)相关关节炎(CPPD)的诊断准确性。以2023年ACR/EULAR标准为参照,iRPolM敏感度86.0%、特异度99.1%、准确率97.5%,与标准高度一致(κ=0.88);仅10%不确定的CPP识别可被iRPolM确认。结论认为iRPolM可简便识别CPP晶体且诊断性能强,单用偏振光显微镜(PLM)对复杂病例特异性不足。

要点

  • iRPolM与2023年ACR/EULAR CPPD标准的一致性强(κ=0.88)。
  • 以2023年ACR/EULAR标准为参照,iRPolM敏感度86.0%、特异度99.1%、准确率97.5%。
  • 仅10%不确定的CPP识别可被iRPolM确认,PLM单用对复杂病例特异性不足。

核心结论

  • iRPolM可简便识别CPP晶体且诊断性能强。
  • 单用PLM对复杂病例特异性不足,在风湿病实践中引入拉曼光谱可能使疑似CPPD患者获益。

研究设计与样本

  • 诊断准确性研究,纳入荷兰一家医院连续400份滑液样本。
  • 以PLM和2023年ACR/EULAR CPPD标准为参照计算准确性指标。

主要发现

  • iRPolM与2023年ACR/EULAR CPPD标准的一致性强(κ=0.88)。
  • 以2023年ACR/EULAR标准为参照,iRPolM敏感度86.0%(95%CI 73.3-94.2)、特异度99.1%(95%CI 97.5-99.8)。
  • 阳性似然比100.33(95%CI 32.3-311.3)、阴性似然比0.14(95%CI 0.07-0.28)。
  • 阳性预测值93.5%(95%CI 82.2-97.8)、阴性预测值98.0%(95%CI 82.2-97.8)、准确率97.5%(95%CI 95.5-98.8)。
  • iRPolM与确定的CPP识别高度一致(κ=0.87),仅10%不确定的CPP识别可被iRPolM确认。

临床怎么用

  • 原文结论认为iRPolM可简便识别CPP晶体且诊断性能强。
  • 原文结论认为单用PLM对复杂病例特异性不足。
  • 原文结论认为在风湿病实践中引入拉曼光谱可能使疑似CPPD患者获益。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: We studied the performance of integrated Raman polarized light microscopy (iRPolM) for the identification of calcium pyrophosphate (CPP)-associated arthritis (CPPD). METHODS: This is a diagnostic accuracy study including 400 consecutive synovial fluid samples from a single hospital in the Netherlands. Accuracy measures were calculated against polarized light microscopy (PLM) and the 2023 American College of Rheumatology (ACR)/EULAR criteria set for CPPD. RESULTS: The interrater reliability between iRPolM and the 2023 ACR/EULAR criteria set for CPPD was strong (κ = 0.88). The diagnostic performance of iRPolM compared to the 2023 ACR/EULAR criteria set was sensitivity 86.0% (95% confidence interval [CI] 73.3-94.2), specificity 99.1% (95% CI 97.5-99.8), positive likelihood ratio 100.33 (95% CI 32.3-311.3), negative likelihood ratio 0.14 (95% CI 0.07-0.28), positive predictive value 93.5% (95% CI 82.2-97.8), negative predictive value 98.0% (95% CI 82.2-97.8), and accuracy 97.5% (95% CI 95.5-98.8). We allowed rheumatologists to rate the certainty of their microscopic identification of CPP and found a large correspondence between iRPolM and a certain identification (κ = 0.87), whereas only 10% of the uncertain CPP identifications could be confirmed with iRPolM. We identified several novel particle types in synovial fluid analysis, including calcium carbonate crystals, deposited carotenoids, microplastics, and three types of Maltese cross birefringent objects. CONCLUSION: iRPolM can easily identify CPP crystals with a strong diagnostic performance. PLM alone is not specific enough to reliably resolve complicated cases, and the implementation of Raman spectroscopy in rheumatology practice can be of benefit to patients with suspected CPPD.

来源:Arthritis Care Res (Hoboken),查看原文。版权归原作者所有。

引用

  1. Niessink T, Janssen M, Giesen T, et al. Diagnostic Accuracy of Raman Spectroscopy Integrated With Polarized Light Microscopy for Calcium Pyrophosphate-Associated Arthritis. Arthritis Care Res (Hoboken). 2024. PMID: 38622108. doi:10.1002/acr.25350

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。