文献速递脊柱关节炎

中轴型脊柱关节炎的诊断准确性:临床信息在骶髂关节影像解读中作用的系统评估

Diagnostic accuracy in axial spondyloarthritis: a systematic evaluation of the role of clinical information in the interpretation of sacroiliac joint imaging.
PubMed 文献 · RMD Open · 2024-04-04

本研究纳入109例疑似中轴型脊柱关节炎(axSpA)患者,其中61例(56%)确诊。三位放射科医生在四轮阅片中独立评估骶髂关节X线和MRI,比较提供临床信息(人口学、SpA特征、体力活动、妊娠)前后影像与临床诊断的符合率及诊断信心。提供临床信息后,X线评估精确率从70%升至78%(p=0.008),X线+MRI从81%升至82%(p=1.0),放射科医生诊断信心均提高。

要点

  • 提供临床信息后,X线评估精确率从70%升至78%(p=0.008)。
  • X线+MRI精确率从81%升至82%(p=1.0),差异未达统计学显著。
  • X线单独评估的敏感度和特异度在提供临床信息后分别为60%和100%,无临床信息时为51%和94%。

核心结论

  • 提供临床信息后,影像学评估的精确率、特异度和诊断信心均提高。

研究设计与样本

  • 从109例因疑似axSpA转诊且影像集完整(骶髂关节X线和MRI)的患者中纳入研究,61例(56%)诊断为axSpA。
  • 图像由三位放射科医生在四轮连续阅片活动中独立评估:X线和X线+MRI,分别在不提供和提供临床信息(包括人口学数据、SpA特征、体力活动和妊娠)的条件下进行。
  • X线按改良纽约标准评分,MRI评估与axSpA相符的炎症和结构改变(是/否),以临床诊断作为参考标准。

主要发现

  • X线评估精确率在不提供临床信息时为70%,提供临床信息后为78%(p=0.008)。
  • X线+MRI评估精确率在不提供临床信息时为81%,提供临床信息后为82%(p=1.0)。
  • X线单独评估的敏感度和特异度在不提供临床信息时为51%和94%,提供临床信息后为60%和100%。
  • X线+MRI评估的敏感度和特异度在不提供临床信息时为74%和90%,提供临床信息后为71%和98%。
  • 放射科医生诊断信心(0-10分)在X线评估时从5.2±1.9升至6.0±1.7,在X线+MRI评估时从6.7±1.6升至7.2±1.6。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Radiography and MRI of the sacroiliac joints (SIJ) are relevant for the diagnosis and classification of patients with axial spondyloarthritis (axSpA). This study aimed to evaluate the impact of clinical information (CI) on the accuracy of imaging interpretation. METHODS: Out of 109 patients referred because of suspicion of axSpA with complete imaging sets (radiographs and MRI of SIJ), 61 were diagnosed with axSpA (56%). Images were independently evaluated by three radiologists in four consecutive reading campaigns: radiographs and radiographs+MRI without and with CI including demographic data, SpA features, physical activity and pregnancy. Radiographs were scored according to the modified New York criteria, and MRIs for inflammatory and structural changes compatible with axSpA (yes/no). The clinical diagnosis was taken as reference standard. The compatibility of imaging findings with a diagnosis of axSpA (precision) before and after the provision of CI and radiologists' confidence with their findings (0-10) were evaluated. RESULTS: The precision of radiographs evaluation without versus with CI increased from 70% to 78% (p=0.008), and for radiographs+MRI from 81% to 82% (p=1.0), respectively. For CR alone, the sensitivity and specificity of radiologic findings were 51% and 94% without and 60% and 100% with CI, while, for radiographs+MRI, they were 74% and 90% vs 71% and 98%, respectively. The diagnostic confidence of radiologists increased from 5.2±1.9 to 6.0±1.7 with CI for radiographs, and from 6.7±1.6 to 7.2±1.6 for radiographs+MRI, respectively. CONCLUSION: The precision, specificity and diagnostic confidence of radiologic evaluation increased when CI was provided.

来源:RMD Open,查看原文。版权归原作者所有。

引用

  1. Pohlner T, Deppe D, Ziegeler K, et al. Diagnostic accuracy in axial spondyloarthritis: a systematic evaluation of the role of clinical information in the interpretation of sacroiliac joint imaging. RMD Open. 2024. PMID: 38580341. doi:10.1136/rmdopen-2023-004044

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。