文献速递自身炎症与 IgG4 相关病

新型唾液腺超声评分系统对IgG4相关涎腺炎的诊断价值

Diagnostic value of a novel salivary gland ultrasound scoring system in IgG4-related sialadenitis.
PubMed 文献 · Rheumatology (Oxford) · 2025-01-01

该研究开发了一种用于IgG4相关涎腺炎(IgG4-RS)患者主要唾液腺的新型超声评分系统,并在中国多中心队列中评估其诊断价值。共纳入470人(187例IgG4-RS,283例非IgG4-RS),IgG4-RS组超声评分显著高于非IgG4-RS组(均值16 vs 4,P<0.001),总评分曲线下面积为0.852(95%CI:0.814,0.891),评分≥9时灵敏度75.4%、特异度91.9%。评分与血清IgG4水平及低补体血症正相关,与血清C3、C4水平负相关。

要点

  • 新型唾液腺超声评分系统总分范围0-34分,观察者间和观察者内信度均优秀(0.972和0.940)。
  • IgG4-RS组超声评分均值16,显著高于非IgG4-RS组的4(P<0.001)。
  • 总评分≥9分诊断IgG4-RS的灵敏度为75.4%,特异度为91.9%。

核心结论

  • 开发了一种用于IgG4-RS患者的半定量超声评分系统,诊断性能良好,观察者间和观察者内信度优秀,超声评分与IgG4、C3、C4水平及低补体血症相关。

研究设计与样本

  • 由20名临床医生(风湿科、口腔科和放射科)参与,在中国多中心队列中分四步开发并评估新型唾液腺超声评分系统的信度和诊断价值。

主要发现

  • IgG4-RS组平均超声评分为16,非IgG4-RS组为4,两组差异有统计学意义(P<0.001)。
  • 总超声评分的曲线下面积为0.852(95%CI:0.814,0.891)。
  • 总超声评分与血清IgG4水平(r=0.221,P=0.002)及低补体血症(r=0.349,P<0.001)呈正相关。
  • 总超声评分与血清C3水平(r=-0.210,P=0.005)及C4水平(r=-0.303,P<0.001)呈负相关。

关键数值与推荐

  • 新型超声评分系统总分范围为0至34分。
  • 观察者间信度为0.972,观察者内信度为0.940。
  • 总超声评分≥9分诊断IgG4-RS的灵敏度为75.4%,特异度为91.9%。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To develop a novel ultrasound scoring system for the major salivary glands in patients with immunoglobulin G4-related sialadenitis (IgG4-RS) and assess its diagnostic value in a multicentre cohort of Chinese patients. METHODS: Twenty clinicians (rheumatologists, stomatologists and radiologists) participated. The study was conducted in four steps: (i) defining the ultrasonography (US) elements, (ii) developing a novel ultrasound scoring system for US of the salivary glands, (iii) evaluation of inter- and intra-reader reliabilities using the new ultrasound scoring system, and (iv) assessing the diagnostic value of this novel ultrasound scoring system in IgG4-RS patients in a Chinese multicentre cohort. RESULTS: A novel ultrasound scoring system for the salivary glands was developed, with total scores ranging from 0 to 34. The inter- and intra-reader reliabilities of the ultrasound scoring system were excellent (0.972 and 0.940, respectively). A total of 470 people were recruited in this study; 187 patients were diagnosed with IgG4-RS, and the remaining 283 people were diagnosed with non-IgG4-RS. Patients with IgG4-RS group had significantly higher US scores than the non-IgG4-RS group (mean US score = 16 vs 4, P < 0.001). The calculated area under the curve for the total US score was 0.852 (95% CI: 0.814, 0.891). The total US scores ≥9 showed a sensitivity of 75.4% and a specificity of 91.9%. Association analysis showed a positive correlation between total US scores and serum IgG4 levels and hypocomplementaemia (r = 0.221 and r = 0.349, respectively; P = 0.002 and P < 0.001, respectively) and a negative correlation between total US scores and serum C3 and C4 levels (r = -0.210 and r = -0.303, respectively; P = 0.005 and P < 0.001, respectively). CONCLUSION: A novel semiquantitative ultrasound scoring system for patients with IgG4-RS was developed, with good diagnostic performance. The inter- and intra-reader reliabilities were excellent. US scores were correlated with IgG4, C3 and C4 levels and hypocomplementaemia.

来源:Rheumatology (Oxford),查看原文。版权归原作者所有。

引用

  1. Zhou M, Liu Y, Zhang S, et al. Diagnostic value of a novel salivary gland ultrasound scoring system in IgG4-related sialadenitis. Rheumatology (Oxford). 2025. PMID: 38429955. doi:10.1093/rheumatology/keae121

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。