DWI滑动血管征诊断巨细胞动脉炎:一种模式识别方法

DWI scrolling artery sign for the diagnosis of giant cell arteritis: a pattern recognition approach.
PubMed 文献 · RMD Open · 2024-03-22

回顾性纳入156例疑似巨细胞动脉炎(GCA)患者,评估DWI滑动血管征(DSAS)的诊断准确性。专家判读DSAS敏感度73.6%、特异度94.2%,新手分别为59.8%和95.7%。DSAS与T1-BB序列一致性在区域水平为80%(κ=0.59),患者水平为86.5%(κ=0.73)。

要点

  • DSAS定义为颅部皮下组织DWI高信号,滚动图像时呈血管样外观。
  • 专家判读DSAS诊断GCA敏感度73.6%、特异度94.2%。
  • DSAS评估耗时不足1分钟,与T1-BB序列一致性良好。

核心结论

  • DSAS评估耗时不足1分钟,对GCA诊断具有良好的诊断准确性和可靠性,可立即用于临床实践。

研究设计与样本

  • 回顾性纳入156例疑似GCA患者,由专家和新手在四个区域(双侧额颞区及枕区)判读DSAS,并以随访≥6个月后的临床诊断为诊断参考。

主要发现

  • 人群包括87例GCA患者和69例无GCA患者,中位年龄71岁,59%为女性。
  • 专家判读DSAS的敏感度为73.6%、特异度为94.2%;新手判读的敏感度为59.8%、特异度为95.7%。
  • DSAS与T1-BB序列在区域水平的一致性为80%(499/624;κ=0.59),在患者水平为86.5%(135/156;κ=0.73)。
  • 专家间DSAS判读一致性在患者水平为95%(19/20;κ=0.90),在区域水平为91.3%(73/80;κ=0.81)。
  • 专家与新手间DSAS判读一致性在患者水平为87.8%(137/156;κ=0.75),在区域水平为91.2%(569/624;κ=0.77)。

临床怎么用

  • DSAS评估耗时不足1分钟,对GCA诊断具有良好的诊断准确性和可靠性,可立即用于临床实践。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To investigate the diagnostic accuracy of a pattern recognition approach for the evaluation of MRI scans of the head with diffusion-weighted imaging (DWI) in suspected giant cell arteritis (GCA). METHODS: Retrospectively, 156 patients with suspected GCA were included. The 'DWI-Scrolling-Artery-Sign' (DSAS) was defined as hyperintense DWI signals in the cranial subcutaneous tissue that gives the impression of a blood vessel when scrolling through a stack of images. The DSAS was rated by experts and a novice in four regions (frontotemporal and occipital, bilaterally). The temporal, occipital and posterior auricular arteries were assessed in the T1-weighted black-blood sequence (T1-BB). The diagnostic reference was the clinical diagnosis after ≥6 months of follow-up. RESULTS: The population consisted of 87 patients with and 69 without GCA; median age was 71 years and 59% were women. The DSAS showed a sensitivity of 73.6% and specificity of 94.2% (experts) and 59.8% and 95.7% (novice), respectively. Agreement between DSAS and T1-BB was 80% for the region level (499/624; kappa(κ)=0.59) and 86.5% for the patient level (135/156; κ=0.73). Inter-reader agreement was 95% (19/20; κ=0.90) for DSAS on the patient level and 91.3% (73/80; κ=0.81) on the region level for experts. For expert versus novice, inter-reader agreement for DSAS was 87.8% on the patient level (137/156; κ=0.75) and 91.2% on the region level (569/624; κ=0.77). CONCLUSIONS: The DSAS can be assessed in less than 1 min and has a good diagnostic accuracy and reliability for the diagnosis of GCA. The DSAS can be used immediately in clinical practice.