文献速递脊柱关节炎

基于MRI的合成CT:轴性脊柱关节炎患者脊柱结构损伤评估的新方法——与低剂量CT和X线片的比较

MRI-based synthetic CT: a new method for structural damage assessment in the spine in patients with axial spondyloarthritis - a comparison with low-dose CT and radiography.
PubMed 文献 · Ann Rheum Dis · 2024-05-15

在17例轴性脊柱关节炎(axSpA)患者中,比较基于MRI的合成CT(sCT)、低剂量CT(ldCT)和X线片检测脊柱新骨形成(NBF)的能力。以全脊柱ldCT为参考标准,sCT检测NBF的敏感度为0.67、特异度均>0.95,敏感度远高于X线片(0.13),尽管阅片者培训有限。sCT可能对检测和监测axSpA脊柱结构损伤有重要价值,尤其在临床试验中。

要点

  • 以ldCT为参考标准,sCT检测NBF的敏感度为0.67、特异度>0.95,X线片敏感度为0.13。
  • 在X线片可评估的节段(C2-T1和T12-S1),sCT和X线片的敏感度分别为0.61和0.48,特异度均>0.90。
  • sCT的阅片者间平均一致性(kappa)为0.58,ldCT为0.68,X线片为0.56,前缘角处最佳。

核心结论

  • 以ldCT为参考标准,基于MRI的脊柱sCT显示出非常高的特异度,且敏感度远高于X线片,尽管阅片者培训有限。
  • sCT可能对检测和监测axSpA脊柱结构损伤有重要价值,尤其是在临床试验中。

研究设计与样本

  • 对17例axSpA患者行腰椎和颈椎X线片、全脊柱ldCT和sCT检查。
  • sCT使用BoneMRI应用程序(V.1.6,MRIGuidance BV,荷兰乌得勒支)重建,该技术基于双回波梯度序列和机器学习处理流程生成类CT的MR图像。
  • 图像匿名后由四名阅片者盲法阅片,应用Canada-Denmark NBF评估系统评分。

主要发现

  • 四名阅片者NBF病灶平均评分:ldCT为188,sCT为209,X线片为37。
  • 大多数NBF位于椎体前缘角,ldCT平均为163,sCT为166,X线片为35。
  • 以全脊柱ldCT为参考标准,sCT和X线片检测NBF的敏感度分别为0.67和0.13,两者特异度均>0.95。
  • 在X线片可评估的节段(C2-T1和T12-S1),sCT和X线片的敏感度分别为0.61和0.48,特异度均>0.90。
  • 对于小关节,sCT和X线片的敏感度分别为0.46和0.03,特异度均>0.94。

关键数值与推荐

  • 应用Canada-Denmark NBF评估系统对NBF进行评分。
  • 以全脊柱ldCT作为参考标准。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To investigate the ability of MRI-based synthetic CT (sCT), low-dose CT (ldCT) and radiography to detect spinal new bone formation (NBF) in patients with axial spondyloarthritis (axSpA). METHODS: Radiography of lumbar and cervical spine, ldCT and sCT of the entire spine were performed in 17 patients with axSpA. sCT was reconstructed using the BoneMRI application (V.1.6, MRIGuidance BV, Utrecht, NL), a quantitative three-dimensional MRI-technique based on a dual-echo gradient sequence and a machine learning processing pipeline that can generate CT-like MR images. Images were anonymised and scored by four readers blinded to other imaging/clinical information, applying the Canada-Denmark NBF assessment system. RESULTS: Mean scores of NBF lesions for the four readers were 188/209/37 for ldCT/sCT/radiography. Most NBF findings were at anterior vertebral corners with means 163 on ldCT, 166 on sCT and 35 on radiography. With ldCT of the entire spine as reference standard, the sensitivity to detect NBF was 0.67/0.13 for sCT/radiography; both with specificities >0.95. For levels that were assessable on radiography (C2-T1 and T12-S1), the sensitivity was 0.61/0.48 for sCT/radiography, specificities >0.90. For facet joints, the sensitivity was 0.46/0.03 for sCT/radiography, specificities >0.94. The mean inter-reader agreements (kappa) for all locations were 0.68/0.58/0.56 for ldCT/sCT/radiography, best for anterior corners. CONCLUSION: With ldCT as reference standard, MRI-based sCT of the spine showed very high specificity and a sensitivity much higher than radiography, despite limited reader training. sCT could become highly valuable for detecting/monitoring structural spine damage in axSpA, not the least in clinical trials.

来源:Ann Rheum Dis,查看原文。版权归原作者所有。

引用

  1. Willesen ST, Hadsbjerg AE, Møller JM, et al. MRI-based synthetic CT: a new method for structural damage assessment in the spine in patients with axial spondyloarthritis - a comparison with low-dose CT and radiography. Ann Rheum Dis. 2024. PMID: 38490729. doi:10.1136/ard-2023-225444

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。