痛风患者心血管双能CT尿酸晶体成像中常见伪影:匹配对照研究
本研究回顾性分析单中心非心电门控双能CT肺动脉造影,纳入48例痛风患者与48例年龄性别匹配对照,由两名独立观察者判定所有血管绿色着色均为伪影,最常见为条纹伪影(痛风组56% vs 对照组57%)和对比剂混合伪影(51% vs 65%)。默认双能CT测量部分与皮下痛风石值一致,但先进双能CT测量与痛风石不一致。
要点
- 非心电门控双能CT肺动脉造影中血管绿色着色均为伪影,非尿酸盐沉积。
- 痛风组与对照组条纹伪影分别为56%与57%,对比剂混合伪影分别为51%与65%。
- 默认双能CT测量部分与皮下痛风石值一致,但先进双能CT测量不一致。
核心结论
- 在非心电门控双能CT肺动脉造影中,痛风和对照患者均常见可被误判为心血管单钠尿酸盐沉积的伪影。
研究设计与样本
- 回顾性 review 单中心非心电门控双能CT肺动脉造影,纳入48例痛风患者和48例年龄性别匹配对照。
主要发现
- 两名独立观察者将所有血管绿色着色区域归因于伪影。
- 条纹伪影在痛风组为56%、对照组为57%,对比剂混合伪影在痛风组为51%、对照组为65%。
- 部分默认双能CT测量与皮下痛风石报告值一致,但先进双能CT测量与痛风石不一致。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文为回顾性研究。
- 原文为单中心研究。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: There is surging interest in using dual-energy computed tomography (DECT) to identify cardiovascular monosodium urate (MSU) deposits in patients with gout. We sought to examine the prevalence and characterization of cardiovascular DECT artifacts using non-electrocardiogram (EKG)-gated DECT pulmonary angiograms. METHODS: We retrospectively reviewed non-EKG-gated DECT pulmonary angiograms performed on patients with and without gout at a single academic center. We noted the presence and locations of vascular green colorization using the default postprocessing two-material decomposition algorithm for MSU. The high- and low-energy grayscale images and advanced DECT measurements were used to determine whether they were true findings or artifacts. We classified artifacts into five categories: streak, contrast medium mixing, misregistration due to motion, foreign body, and noise. RESULTS: Our study included CT scans from 48 patients with gout and 48 age- and sex-matched controls. The majority of patients were male with a mean age of 67 years. Two independent observers attributed all areas of vascular green colorization to artifacts. The most common types of artifacts were streak (56% vs 57% between patients and controls, respectively) and contrast medium mixing (51% vs 65%, respectively). Whereas some of the default DECT measurements of cardiovascular green colorization were consistent with values reported for subcutaneous tophi, advanced DECT measurements were not consistent with that of tophi. CONCLUSION: Artifacts that could be misconstrued as cardiovascular MSU deposits were commonly identified in patients with and without gout on non-EKG-gated DECT pulmonary angiograms. These artifacts can inform future vascular DECT studies on patients with gout to minimize false-positive findings.
引用
- Yokose C, Eide SE, Huber FA, et al. Frequently Encountered Artifacts in the Application of Dual-Energy Computed Tomography to Cardiovascular Imaging for Urate Crystals in Gout: A Matched-Control Study. Arthritis Care Res (Hoboken). 2024. PMID: 38317327. doi:10.1002/acr.25312
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。