文献速递其他结缔组织病

超声评估间质性肺病的标准化:OMERACT超声工作组德尔菲流程与网络信度练习结果

Standardization of interstitial lung disease assessment by ultrasound: results from a Delphi process and web-reliability exercise by the OMERACT ultrasound working group.
PubMed 文献 · Semin Arthritis Rheum · 2024-02-05

OMERACT超声工作组基于系统文献综述识别超声间质性肺病征象,经23名专家三轮德尔菲调查达成共识定义B线和胸膜线不规则,并通过80段视频片段进行网络信度练习,显示B线和胸膜线不规则均有中等读者间信度和良好读者内信度。

要点

  • 三轮德尔菲调查后达成>75%共识,将B线和胸膜线不规则定义为评估间质性肺病的基本病变。
  • 网络信度练习纳入80段视频片段(胸膜线不规则30段、B线50段),B线读者间kappa=0.51、胸膜线不规则kappa=0.58。
  • 读者内信度B线kappa=0.72、胸膜线不规则kappa=0.75,下一步将在风湿病相关间质性肺病患者中测试信度。

核心结论

  • 获得了B线和胸膜线不规则的共识性超声定义,使用视频片段检测这些病变具有中等至良好信度。
  • 下一步将在风湿和肌肉骨骼疾病相关间质性肺病患者中测试信度,并提出共识性标准化扫描方案。

研究设计与样本

  • 基于系统文献综述结果,在23名超声专家中进行三轮德尔菲调查以就应纳入的征象及其定义达成共识。
  • 随后使用视频片段进行网络信度练习,采用kappa统计检验共识定义的信度。

主要发现

  • 系统文献综述识别出用于定义超声间质性肺病的征象包括A线、B线、胸膜囊肿和胸膜线不规则。
  • 三轮德尔菲调查后获得>75%的共识,纳入并定义B线和胸膜线不规则作为评估的基本病变。
  • 网络信度练习共80段视频片段(胸膜线不规则30段、B线50段),B线读者间kappa=0.51、胸膜线不规则kappa=0.58,均为中等信度。
  • 读者内信度B线kappa=0.72、胸膜线不规则kappa=0.75,均为良好信度。

关键数值与推荐

  • 德尔菲调查共识阈值:三轮后达成>75%的同意,纳入并定义B线和胸膜线不规则为评估的基本病变。
  • 网络信度练习样本:80段视频片段,其中胸膜线不规则30段、B线50段。
  • 读者间信度:B线kappa=0.51,胸膜线不规则kappa=0.58(中等信度)。
  • 读者内信度:B线kappa=0.72,胸膜线不规则kappa=0.75(良好信度)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 信度测试使用视频片段而非在风湿和肌肉骨骼疾病相关间质性肺病患者中进行,作者指出下一步将在患者中测试信度。
  • 原文未报告其他局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: Over the last years ultrasound has shown to be an important tool for evaluating lung involvement, including interstitial lung disease (ILD) a potentially severe systemic involvement in many rheumatic and musculoskeletal diseases (RMD). Despite the potential sensitivity of the technique the actual use is hampered by the lack of consensual definitions of elementary lesions to be assessed and of the scanning protocol to apply. Within the Outcome Measures in Rheumatology (OMERACT) Ultrasound Working Group we aimed at developing consensus-based definitions for ultrasound detected ILD findings in RMDs and assessing their reliability in dynamic images. METHODS: Based on the results from a systematic literature review, several findings were identified for defining the presence of ILD by ultrasound (i.e., Am-lines, B-lines, pleural cysts and pleural line irregularity). Therefore, a Delphi survey was conducted among 23 experts in sonography to agree on which findings should be included and on their definitions. Subsequently, a web-reliability exercise was performed to test the reliability of the agreed definitions on video-clips, by using kappa statistics. RESULTS: After three rounds of Delphi an agreement >75 % was obtained to include and define B-lines and pleural line irregularity as elementary lesions to assess. The reliability in the web-based exercise, consisting of 80 video-clips (30 for pleural line irregularity, 50 for B-lines), showed moderate inter-reader reliability for both B-lines (kappa = 0.51) and pleural line irregularity (kappa = 0.58), while intra-reader reliability was good for both B-lines (kappa = 0.72) and pleural line irregularity (kappa = 0.75). CONCLUSION: Consensus-based ultrasound definitions for B-lines and pleural line irregularity were obtained, with moderate to good reliability to detect these lesions using video-clips. The next step will be testing the reliability in patients with ILD linked to RMDs and to propose a consensual and standardized protocol to scan such patients.

来源:Semin Arthritis Rheum,查看原文。版权归原作者所有。

引用

  1. Delle Sedie A, Terslev L, Bruyn GAW, et al. Standardization of interstitial lung disease assessment by ultrasound: results from a Delphi process and web-reliability exercise by the OMERACT ultrasound working group. Semin Arthritis Rheum. 2024. PMID: 38401294. doi:10.1016/j.semarthrit.2024.152406

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。