文献速递脊柱关节炎

验证SPARCC MRI-RETIC电子工具对提高中轴型脊柱关节炎骶髂关节MRI病变评分熟练度的作用

Validation of SPARCC MRI-RETIC e-tools for increasing scoring proficiency of MRI sacroiliac joint lesions in axial spondyloarthritis.
PubMed 文献 · RMD Open · 2024-02-13

SPARCC开发者创建了基于网络的SPARCC MRI骶髂关节评分校准模块,本研究测试其可行性与可靠性。来自EuroSpA Imaging项目的17名阅片者被随机分配至两种各含三阶段的校准策略,每阶段后对25例基线及随访扫描评分。骨髓水肿评分可靠性在第一阶段后即较高,结构模块对侵蚀和回填的可靠性提升更明显,两种电子模块可行性均通过高SUS评分体现。

要点

  • 骨髓水肿评分可靠性在第一阶段校准后即较高,炎症模块使用后仅见轻微改善。
  • 结构模块使用后阅片者可靠性提升更明显,侵蚀和回填评分最一致。
  • 两种电子模块可行性均通过高系统可用性量表(SUS)评分体现。

核心结论

  • SPARCC-SIJ RETIC电子模块是可行且有效的知识转化工具,推荐在将SPARCC方法用于临床研究和试验前使用。

研究设计与样本

  • SPARCC开发者创建了基于网络的SPARCC MRI骶髂关节评分校准模块,包含基线和随访扫描病例及在线评分界面。
  • 来自EuroSpA Imaging项目的17名参与阅片者被随机分配至两种各含三阶段的阅片者校准策略。
  • 每阶段完成后对25例病例的基线和随访扫描进行评分,并与SPARCC开发者进行可靠性比较,同时用系统可用性量表(SUS)评估可行性。

主要发现

  • 骨髓水肿评分可靠性在第一阶段校准后即较高,使用炎症模块后仅见轻微改善。
  • 结构模块使用后阅片者可靠性提升更明显,侵蚀评分ICC(状态/变化)从阶段1的0.42/0.20升至阶段3的0.50/0.38。
  • 回填评分ICC(状态/变化)从阶段1的0.51/0.19升至阶段3的0.69/0.41。
  • 两种电子模块的可行性均通过高SUS评分体现。

关键数值与推荐

  • 骨髓水肿评分可靠性在第一阶段校准后即较高,炎症模块后仅轻微改善。
  • 侵蚀评分ICC(状态/变化)阶段1为0.42/0.20,阶段3为0.50/0.38。
  • 回填评分ICC(状态/变化)阶段1为0.51/0.19,阶段3为0.69/0.41。
  • 两种电子模块可行性均通过高SUS评分体现。

临床怎么用

  • 作者结论推荐在将SPARCC方法用于临床研究和试验前使用SPARCC-SIJ RETIC电子模块。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: The Spondyloarthritis Research Consortium of Canada (SPARCC) developers have created web-based calibration modules for the SPARCC MRI sacroiliac joint (SIJ) scoring methods. We aimed to test the impact of applying these e-modules on the feasibility and reliability of these methods. METHODS: The SPARCC-SIJ RETIC e-modules contain cases with baseline and follow-up scans and an online scoring interface. Visual real-time feedback regarding concordance/discordance of scoring with expert readers is provided by a colour-coding scheme. Reliability is assessed in real time by intraclass correlation coefficient (ICC), cases being scored until ICC targets are attained. Participating readers (n=17) from the EuroSpA Imaging project were randomised to one of two reader calibration strategies that each comprised three stages. Baseline and follow-up scans from 25 cases were scored after each stage was completed. Reliability was compared with a SPARCC developer, and the System Usability Scale (SUS) assessed feasibility. RESULTS: The reliability of readers for scoring bone marrow oedema was high after the first stage of calibration, and only minor improvement was noted following the use of the inflammation module. Greater enhancement of reader reliability was evident after the use of the structural module and was most consistently evident for the scoring of erosion (ICC status/change: stage 1 (0.42/0.20) to stage 3 (0.50/0.38)) and backfill (ICC status/change: stage 1 (0.51/0.19) to stage 3 (0.69/0.41)). The feasibility of both e-modules was evident by high SUS scores. CONCLUSION: The SPARCC-SIJ RETIC e-modules are feasible, effective knowledge transfer tools, and their use is recommended before using the SPARCC methods for clinical research and tria.

来源:RMD Open,查看原文。版权归原作者所有。

引用

  1. Maksymowych W, Hadsbjerg AEFEF, Østergaard M, et al. Validation of SPARCC MRI-RETIC e-tools for increasing scoring proficiency of MRI sacroiliac joint lesions in axial spondyloarthritis. RMD Open. 2024. PMID: 38351052. doi:10.1136/rmdopen-2023-003923

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。