文献速递痛风与晶体性关节病

超声诊断焦磷酸钙晶体沉积病:应扫描多少个及哪些部位

Diagnosis of calcium pyrophosphate crystal deposition disease by ultrasonography: how many and which sites should be scanned?
PubMed 文献 · Rheumatology (Oxford) · 2024-01-01

该横断面研究在两家意大利机构前瞻性纳入204例受试者(102例经晶体证实的焦磷酸钙晶体沉积病患者与102例年龄、性别匹配的滑液分析阴性疾病对照),由4名风湿科医生按标准化方案盲法超声检查20个关节。通过LASSO技术筛选信息量最大的关节建立简化扫描方案,发现双侧评估膝、腕、髋关节且≥2个关节检出焦磷酸钙晶体沉积对诊断该病具有优秀准确性和良好可行性。

要点

  • 焦磷酸钙晶体沉积病患者超声检出晶体的关节数中位数为5个(IQR 4-7),对照为0个(IQR 0-1)(P<0.01)。
  • 简化方案(双侧膝、腕、髋关节)中≥2个关节检出晶体诊断焦磷酸钙晶体沉积病的敏感性为96.7%(95%CI 82.8-99.9),特异性为100%(95%CI 88.8-100.0)。
  • 简化方案平均检查时间为12.5(5.3)分钟,可行性良好。

核心结论

  • 双侧超声评估膝、腕和髋关节对焦磷酸钙晶体沉积病的诊断具有优秀准确性和良好可行性。

研究设计与样本

  • 横断面研究,在两家意大利机构前瞻性连续纳入经晶体证实的焦磷酸钙晶体沉积病患者及年龄、性别匹配的滑液分析阴性疾病对照,共204例(102例对102例)。
  • 4名对临床资料不知情的风湿科医生按标准化方案超声检查20个关节(肩、肘、腕、第2至第5指掌指关节、髋、膝、踝),按OMERACT定义判定焦磷酸钙晶体沉积的有无。
  • 采用LASSO技术筛选信息量最大的关节建立简化超声扫描方案,患者随机分为训练集和验证集,通过比较受试者工作特征曲线下面积检验诊断准确性。

主要发现

  • 焦磷酸钙晶体沉积病患者超声检出晶体的关节数中位数为5个(IQR 4-7),疾病对照为0个(IQR 0-1),两组比较P<0.01。
  • 简化扫描方案(双侧评估膝、腕和髋关节)中≥2个关节检出焦磷酸钙晶体沉积诊断该病的敏感性为96.7%(95%CI 82.8-99.9),特异性为100%(95%CI 88.8-100.0)。
  • 简化方案的平均检查时间为12.5(5.3)分钟,可行性良好。

关键数值与推荐

  • 焦磷酸钙晶体沉积的超声判定采用OMERACT定义,按存在/不存在记录。
  • 简化方案诊断阈值:双侧膝、腕、髋关节中≥2个关节检出焦磷酸钙晶体沉积。
  • 简化方案诊断准确性:敏感性96.7%(95%CI 82.8-99.9),特异性100%(95%CI 88.8-100.0)。

临床怎么用

  • 原文结论认为双侧超声评估膝、腕和髋关节对焦磷酸钙晶体沉积病的诊断具有优秀准确性和良好可行性。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To develop the optimal US scanning protocol for the diagnosis of calcium pyrophosphate crystal deposition (CPPD) disease. METHODS: In this cross-sectional study, consecutive patients with a crystal-proven diagnosis of CPPD disease, and age-, sex-matched disease controls with a negative synovial fluid analysis were prospectively enrolled in two Italian Institutions. Four rheumatologists, blinded to patients' clinical details, performed US examinations using a standardized scanning protocol including 20 joints (shoulders, elbows, wrists, metacarpophalangeal joints from second to fifth fingers, hips, knees, ankles). CPPD was identified as presence/absence, according to the OMERACT definitions. Reduced US scanning protocols were developed by selecting the most informative joints to be imaged by US using the LASSO technique. Patients were randomly divided into training and validation sets. Their diagnostic accuracy was tested comparing the area under the receiver operating characteristic curves. RESULTS: The number of participants enrolled was 204: 102 with CPPD disease and 102 disease controls [age, mean (s.d.): 71.3 (12.0) vs 71.1 (13.5) years; female: 62.8% vs 57.8%]. The median number of joints with US evidence of CPPD was 5 [interquartile range (IQR): 4-7] and 0 (IQR: 0-1) in patients with CPPD disease and controls, respectively (P < 0.01). The detection of CPPD in ≥2 joints using a reduced scanning protocol (bilateral assessment of knees, wrists and hips) showed a sensitivity of 96.7% (95% CI: 82.8, 99.9) and a specificity of 100 (95% CI: 88.8, 100.0) for the diagnosis of CPPD disease and had good feasibility [mean (s.d.): 12.5 (5.3) min]. CONCLUSION: Bilateral US assessment of knees, wrists and hips had excellent accuracy and good feasibility for the diagnosis of CPPD disease.

来源:Rheumatology (Oxford),查看原文。版权归原作者所有。

引用

  1. Cipolletta E, Moscioni E, Sirotti S, et al. Diagnosis of calcium pyrophosphate crystal deposition disease by ultrasonography: how many and which sites should be scanned? Rheumatology (Oxford). 2024. PMID: 37882749. doi:10.1093/rheumatology/kead565

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。