弥散加权磁共振成像诊断巨细胞动脉炎:与T1加权黑血成像的比较
回顾性纳入156例临床疑似巨细胞动脉炎(GCA)患者,开发4点序数DWI评分量表,并与增强脂肪抑制T1加权黑血序列(T1-BB)比较诊断效能,以随访≥6个月的专家临床诊断为参考标准。DWI的曲线下面积为0.90;≥2个连续病理切片界值时敏感度75.9%、特异度94.2%、阳性似然比13.09;≥3个连续病理切片界值时敏感度70.1%、特异度98.6%、阳性似然比48.38;T1-BB相应值为88.5%、88.4%和7.63。结论认为DWI对GCA诊断具有良好的诊断准确性和可靠性,可立即用于临床实践。
要点
- DWI诊断GCA的曲线下面积为0.90。
- DWI界值≥2个连续病理切片时敏感度75.9%、特异度94.2%、阳性似然比13.09。
- DWI界值≥3个连续病理切片时敏感度70.1%、特异度98.6%、阳性似然比48.38。
核心结论
- DWI对浅表颅动脉诊断GCA显示出良好的诊断准确性和可靠性。
- DWI广泛可用,可立即用于临床实践中疑似GCA的患者。
研究设计与样本
- 回顾性纳入156例临床疑似GCA的患者。
- 开发了新的4点序数DWI评分量表,并与增强脂肪抑制T1加权黑血序列(T1-BB)进行评分比较。
- 评估10个动脉节段:双侧颞浅动脉总干、颞支和顶支、枕动脉和耳后动脉。
- 以随访≥6个月后的专家临床诊断为诊断参考标准,评估不同评分方法的诊断准确性。
主要发现
- 研究队列包括87例GCA患者和69例无GCA患者。
- DWI的曲线下面积为0.90。
- DWI界值≥2个连续病理切片时,敏感度75.9%、特异度94.2%、阳性似然比13.09。
- DWI界值≥3个连续病理切片时,敏感度70.1%、特异度98.6%、阳性似然比48.38。
- T1-BB的敏感度88.5%、特异度88.4%、阳性似然比7.63。
关键数值与推荐
- DWI界值≥2个连续病理切片时,患者水平kappa为1.00,动脉节段水平kappa为0.85。
- T1-BB的患者水平kappa为0.78,动脉节段水平kappa为0.79。
临床怎么用
- DWI广泛可用,可立即用于临床实践中疑似GCA的患者。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: To investigate the diagnostic performance of diffusion-weighted imaging (DWI) of the superficial cranial arteries in the diagnosis of GCA. METHODS: Retrospectively, 156 patients with clinically suspected GCA were included. A new 4-point ordinal DWI rating scale was developed. A post-contrast, fat-suppressed, T1-weighted 'black-blood' sequence (T1-BB) was rated for comparison. Ten arterial segments were assessed: common superficial temporal arteries, temporal and parietal branches, occipital and posterior auricular arteries bilaterally. The expert clinical diagnosis after ≥6 months of follow-up was the diagnostic reference standard. Diagnostic accuracy was evaluated for different rating methods. RESULTS: The study cohort consisted of 87 patients with and 69 without GCA. For DWI, the area under the curve was 0.90. For a cut-off of ≥2 consecutive pathological slices, DWI showed a sensitivity of 75.9%, a specificity of 94.2% and a positive likelihood ratio of 13.09. With a cut-off of ≥3 consecutive pathological slices, sensitivity was 70.1%, specificity was 98.6% and the positive likelihood ratio was 48.38. For the T1-BB, values were 88.5%, 88.4% and 7.63, respectively. The inter-rater analysis for DWI with a cut-off of ≥2 pathological slices showed a kappa of 1.00 on the patient level and 0.85 on the arterial segment level. For the T1-BB the kappa was 0.78 and 0.79, respectively. CONCLUSION: DWI of the superficial cranial arteries demonstrates a good diagnostic accuracy and reliability for the diagnosis of GCA. DWI is widely available and can be used immediately in clinical practice for patients with suspected GCA.
引用
- Seitz L, Bucher S, Bütikofer L, et al. Diffusion-weighted magnetic resonance imaging for the diagnosis of giant cell arteritis: a comparison with T1-weighted black-blood imaging. Rheumatology (Oxford). 2024. PMID: 37555808. doi:10.1093/rheumatology/kead401
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。