预测磁共振成像上骶髂关节骨髓水肿的机器学习流程
本研究开发并验证了一种全自动机器学习算法,在骶髂关节磁共振成像上按象限水平预测骨髓水肿。炎症分类器在脊柱关节炎患者、产后个体和健康受试者的扫描上进行五折交叉验证,并在独立脊柱关节炎患者数据集中测试。该流程在交叉验证和测试集中均表现良好,有望用于筛查大量疑似脊柱关节炎患者。
要点
- 算法自动检测骶髂关节精确度98.4%,分割髂骨和骶骨的交并比分别为85.6%和67.9%。
- 炎症分类器交叉验证AUC 94.5%、平衡准确率80.5%、F1分数64.1%。
- 测试集AUC 88.2%、平衡准确率72.1%、F1分数50.8%。
核心结论
- 作者提出一种全自动机器学习流程,可对磁共振成像上骶髂关节骨髓水肿进行客观和标准化评估。
- 该方法有潜力筛查大量(疑似)脊柱关节炎患者,并朝人工智能辅助诊断和随访迈进一步。
研究设计与样本
- 计算机视觉工作流自动定位骶髂关节,分割感兴趣区域(髂骨和骶骨),进行客观象限提取,并在T1/T2加权磁共振扫描的半冠状切面上按象限水平预测骨髓水肿的存在。
- 炎症分类器使用ResNet18骨干网络训练,在脊柱关节炎患者(n=279)、产后个体(n=71)和健康受试者(n=114)的扫描上进行五折交叉验证。
- 独立脊柱关节炎患者磁共振扫描(n=243)作为测试数据集;患者水平预测由象限水平预测聚合而来,即至少一个阳性象限。
主要发现
- 算法自动检测骶髂关节精确度为98.4%,分割髂骨和骶骨的交并比分别为85.6%和67.9%。
- 炎症分类器在交叉验证中表现良好:AUC 94.5%、平衡准确率80.5%、F1分数64.1%。
- 在测试数据集中,AUC为88.2%、平衡准确率72.1%、F1分数50.8%。
- 在患者水平,模型在交叉验证和测试数据集中的平衡准确率分别为81.6%和81.4%。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: We aimed to develop and validate a fully automated machine learning (ML) algorithm that predicts bone marrow edema (BME) on a quadrant level in sacroiliac (SI) joint magnetic resonance imaging (MRI). METHODS: A computer vision workflow automatically locates the SI joints, segments regions of interest (ilium and sacrum), performs objective quadrant extraction, and predicts presence of BME, suggestive of inflammatory lesions, on a quadrant level in semicoronal slices of T1/T2-weighted MRI scans. Ground truth was determined by consensus among human readers. The inflammation classifier was trained using a ResNet18 backbone and five-fold cross-validated on scans of patients with spondyloarthritis (SpA) (n = 279), postpartum individuals (n = 71), and healthy subjects (n = 114). Independent SpA patient MRI scans (n = 243) served as test data set. Patient-level predictions were derived from aggregating quadrant-level predictions, ie, at least one positive quadrant. RESULTS: The algorithm automatically detects the SI joints with a precision of 98.4% and segments ilium/sacrum with an intersection over union of 85.6% and 67.9%, respectively. The inflammation classifier performed well in cross-validation: area under the curve (AUC) 94.5%, balanced accuracy (B-ACC) 80.5%, and F1 score 64.1%. In the test data set, AUC was 88.2%, B-ACC 72.1%, and F1 score 50.8%. On a patient level, the model achieved a B-ACC of 81.6% and 81.4% in the cross-validation and test data set, respectively. CONCLUSION: We propose a fully automated ML pipeline that enables objective and standardized evaluation of BME along the SI joints on MRI. This method has the potential to screen large numbers of patients with (suspected) SpA and is a step closer towards artificial intelligence-assisted diagnosis and follow-up.
引用
- Roels J, De Craemer AS, Renson T, et al. Machine Learning Pipeline for Predicting Bone Marrow Edema Along the Sacroiliac Joints on Magnetic Resonance Imaging. Arthritis Rheumatol. 2023. PMID: 37410803. doi:10.1002/art.42650
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。