文献速递痛风与晶体性关节病

超声动态评估双轨征有助于鉴别痛风和焦磷酸钙沉积病

Dynamic assessment of the double contour sign by ultrasonography helps to distinguish between gout and calcium pyrophosphate deposition disease.
PubMed 文献 · RMD Open · 2023-01-01

该横断面分析纳入81例符合2015年ACR/EULAR分类标准的痛风患者和84例晶体证实的焦磷酸钙沉积病(CPPD)患者,用超声检测透明软骨双轨征(DC征)并评估其动态行为。静态评估DC征诊断痛风的敏感度58.0%、特异度89.3%、准确率73.9%;动态评估后特异度升至97.6%、准确率升至78.2%,敏感度无损失(p=0.01)。作者认为动态超声评估DC征可能有助于区分痛风与CPPD。

要点

  • 静态DC征诊断痛风敏感度58.0%、特异度89.3%、准确率73.9%。
  • 动态评估后特异度97.6%、准确率78.2%,敏感度无损失(p=0.01)。
  • 47/47例痛风患者动态评估为DC征,7/9例(77.8%)CPPD患者为假性DC征(p<0.01)。

核心结论

  • 动态超声评估DC征可能有助于区分痛风尿酸盐结晶所致DC征与CPPD中所见的假性DC征,二者运动方向相反。

研究设计与样本

  • 横断面分析纳入81例符合2015年ACR/EULAR分类标准的痛风患者和84例晶体证实的CPPD患者。
  • 对透明软骨行超声检测DC征(即透明软骨浅表边缘异常强回声带),并评估关节运动时的动态行为(DC征随软骨下骨移动为DC征,反向移动为假性DC征)。

主要发现

  • 81例痛风患者和84例CPPD患者接受超声评估,其中47例痛风患者和9例CPPD患者有DC征证据。
  • 动态评估中,47/47例痛风患者为DC征,7/9例(77.8%)CPPD患者为假性DC征(p<0.01)。
  • 静态评估DC征诊断痛风的敏感度58.0%(95%CI 46.5%至68.9%)、特异度89.3%(95%CI 80.6%至95.0%)、准确率73.9%(95%CI 66.5%至80.5%)。
  • 动态评估改善DC征诊断性能(p=0.01),特异度97.6%(95%CI 91.7%至99.7%)和准确率78.2%(95%CI 71.1%至84.2%)升高,敏感度无损失。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To test whether the double contour (DC) sign has a different dynamic behaviour in gout and calcium pyrophosphate deposition (CPPD) and whether the dynamic assessment of the DC sign increases its accuracy in gout diagnosis. METHODS: This cross-sectional analysis included patients with gout meeting the 2015 ACR/EULAR classification criteria and patients with crystal-proven diagnosis of CPPD. Hyaline cartilages were explored by ultrasound (US) to detect the DC sign (ie, abnormal hyperechoic band over the superficial margin of hyaline cartilages) and its dynamic behaviour during joint movement was evaluated ((ie, movement of the DC sign together with subchondral bone (DC sign), or in the opposite direction (pseudo DC sign)). RESULTS: Eighty-one patients with gout and 84 patients with CPPD underwent US assessment. Among them, 47 patients with gout and 9 patients with CPPD had evidence of the DC sign. During dynamic assessment, in all 47/47 patients with gout there was a DC sign. Conversely, in 7/9 (77.8%) patients with CPPD, there was a pseudo DC sign (p<0.01).The presence of DC sign during static assessment had a sensitivity, specificity and accuracy of 58.0% (95% CI 46.5% to 68.9%), 89.3% (95% CI 80.6% to 95.0%) and 73.9% (95% CI 66.5% to 80.5%) for gout, respectively. The dynamic evaluation improved the DC sign's diagnostic performance (p=0.01) as the specificity (97.6% (95% CI 91.7% to 99.7%)) and the accuracy (78.2% (95% CI 71.1% to 84.2%)) increased without loss in sensitivity. CONCLUSION: The dynamic US assessment of the DC sign may help to differentiate the DC sign due to MSU crystals from the pseudo DC sign seen in CPPD, as they move in opposite directions.

来源:RMD Open,查看原文。版权归原作者所有。

引用

  1. Cipolletta E, Abhishek A, Di Matteo A, et al. Dynamic assessment of the double contour sign by ultrasonography helps to distinguish between gout and calcium pyrophosphate deposition disease. RMD Open. 2023. PMID: 36927850. doi:10.1136/rmdopen-2022-002940

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。