文献速递类风湿关节炎

类风湿关节炎发生前手功能已受损并反映亚临床腱鞘炎

Hand function is already reduced before RA development and reflects subclinical tenosynovitis.
PubMed 文献 · RMD Open · 2023-01-01

该研究在两个临床可疑关节痛(CSA)人群中评估手功能,发现手功能受损常见,且与亚临床炎症尤其是腱鞘炎相关;握力下降对检出腱鞘炎最敏感,而拳闭合不全最具特异性。

要点

  • 在TREAT EARLIER试验的236例CSA患者中,75%握力(测力计)低于健康对照参考值,60%报告握持困难,13%拳闭合不全。
  • 握力下降与亚临床炎症相关,且独立关联腱鞘炎;患者报告的握持困难和拳闭合不全也与腱鞘炎相关。
  • 验证队列600例中,36%检查者评估握力下降,51%报告握持困难,14%拳闭合不全,均与腱鞘炎相关。

核心结论

  • 手功能在类风湿关节炎(RA)发生前已常受损,这些受限与亚临床炎症尤其腱鞘炎相关。

研究设计与样本

  • 研究在两个临床可疑关节痛(CSA)人群中评估手功能:TREAT EARLIER试验的CSA患者(n=236)和独立验证CSA队列(n=600),并使用手部对比增强MRI测量滑膜炎、腱鞘炎和骨髓水肿(合计为亚临床炎症)。

主要发现

  • 在TREAT EARLIER试验CSA患者中,测力计握力(GS)较健康对照参考值下降者占75%,报告握持困难者占60%,体格检查拳闭合不全者占13%。
  • 握力下降与亚临床炎症相关(每点炎症-0.38 kg,95% CI -0.68至-0.08);握力下降独立关联腱鞘炎,每点腱鞘炎评分下降-2.63 kg(95% CI -2.26至-0.33),观察到的腱鞘炎评分范围为0-20。
  • 患者报告的握持困难(每点OR 1.12,95% CI 1.07至1.42)和拳闭合不全(每点OR 1.36,95% CI 1.03至1.79)与腱鞘炎呈相似关联。
  • 在验证队列中,36%检查者评估握力下降,51%报告握持困难,14%拳闭合不全,均与腱鞘炎相关。
  • 测力计握力下降对检出腱鞘炎最敏感(75%),而拳闭合不全最具特异性(88%-90%)。

关键数值与推荐

  • 握力下降与亚临床炎症的关联:每点炎症-0.38 kg(95% CI -0.68至-0.08)。
  • 握力下降与腱鞘炎的独立关联:每点腱鞘炎评分-2.63 kg(95% CI -2.26至-0.33),腱鞘炎评分范围0-20。
  • 患者报告握持困难与腱鞘炎的关联:每点OR 1.12(95% CI 1.07至1.42)。
  • 拳闭合不全与腱鞘炎的关联:每点OR 1.36(95% CI 1.03至1.79)。
  • 测力计握力下降检出腱鞘炎的敏感性为75%,拳闭合不全的特异性为88%-90%。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

BACKGROUND: Clinically suspect arthralgia (CSA) is characterised by arthralgia of small joints and considered a risk stage for development of rheumatoid arthritis (RA). However, it remains unknown if the function of the hands is already affected and what mechanisms underlie impaired hand-function in CSA. METHODS: We studied various measures of hand function in two CSA populations. CSA patients in the TREAT EARLIER-trial (n=236) were evaluated at baseline for: grip strength on a dynamometer (GS), patient-reported difficulties in the grip domain of the Health Assessment Questionnaire (HAQ) questionnaire and incomplete fist closure at physical examination. Findings were validated in an independent CSA cohort (n=600) where hand function was measured as: GS evaluated by squeezing the examiner's fingers, grip domain of the HAQ questionnaire and fist closure. Contrast-enhanced MRI of the hands measured synovitis, tenosynovitis and bone marrow oedema (summed as subclinical inflammation) in both cohorts. RESULTS: GS (on a dynamometer) was reduced in 75% compared with reference values in healthy controls, 60% reported grip difficulties and 13% had incomplete fist closure. Reduced GS was associated with subclinical inflammation (-0.38 kg/point inflammation, 95% CI -0.68 to -0.08). Studying separate MRI features, GS reduction was independently associated with tenosynovitis, decreasing with -2.63 kg (95% CI -2.26 to -0.33)/point tenosynovitis (range observed tenosynovitis scores: 0-20). Similar relations with tenosynovitis were seen for patient-reported grip difficulties (OR 1.12/point, 95% CI 1.07 to 1.42) and incomplete fist closure (OR 1.36/point, 95% CI 1.03 to 1.79). In the validation cohort, 36% had decreased examiner-assessed GS, 51% reported grip difficulties and 14% incomplete fist closure: all were associated with tenosynovitis. Decreased dynamometer-measured GS was most sensitive for detecting tenosynovitis (75%), while incomplete fist closure was most specific (88%-90%). CONCLUSION: Hand function is already often affected before RA development. These limitations are related to subclinical inflammation and tenosynovitis in particular.

来源:RMD Open,查看原文。版权归原作者所有。

引用

  1. Krijbolder DI, Khidir SJH, Matthijssen XME, et al. Hand function is already reduced before RA development and reflects subclinical tenosynovitis. RMD Open. 2023. PMID: 36759005. doi:10.1136/rmdopen-2022-002885

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。