文献速递血管炎

巨细胞动脉炎的临时OMERACT超声评分

The provisional OMERACT ultrasonography score for giant cell arteritis.
PubMed 文献 · Ann Rheum Dis · 2022-12-12

该研究遵循OMERACT仪器选择算法,经七轮德尔菲(Delphi)调查就巨细胞动脉炎(GCA)超声评分OGUS达成92.7%共识,并在35名成员中完成信度测试,组间ICC为0.72-0.84,组内ICC中位数0.91。前瞻性队列52例新发GCA患者中,OGUS在24周内各随访点较基线的标准化均数差为-1.19至-2.16,与ESR、CRP及BVAS呈中度相关(相关系数0.37-0.48)。

要点

  • OGUS计算方法:各节段IMT测量值除以该节段IMT四舍五入界值后求和,再除以可用节段数。
  • 35名成员参与信度测试,OGUS组间ICC为0.72-0.84,组内ICC中位数0.91。
  • 52例新发GCA前瞻性队列中,OGUS至第24周各随访点较基线标准化均数差为-1.19至-2.16。

核心结论

  • 研究制定了临时OGUS,可能用于临床试验。

研究设计与样本

  • 遵循OMERACT仪器选择算法,邀请49名OMERACT超声大血管血管炎工作组成员参加七轮德尔菲调查。
  • 使用16例GCA患者和7例对照的双侧颞浅动脉、顶支和额支以及腋动脉图像进行在线信度测试。
  • 使用新发GCA前瞻性队列数据检验敏感性和收敛结构效度,该队列在第1、3、6、12和24周进行超声IMT测量,共52例患者。

主要发现

  • OGUS获得92.7%的同意率,计算方法为各节段IMT测量值除以该节段IMT四舍五入界值后求和,再除以可用节段数。
  • 35名成员完成信度测试,OGUS组间ICC为0.72-0.84,组内ICC中位数为0.91。
  • 前瞻性队列52例患者中,基线至第24周各随访点的标准化均数差为-1.19至-2.16,分别对应大和非常大的变化幅度。
  • OGUS与红细胞沉降率、C反应蛋白和伯明翰血管炎活动评分呈中度相关(相关系数0.37-0.48)。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To develop an Outcome Measures in Rheumatology (OMERACT) ultrasonography score for monitoring disease activity in giant cell arteritis (GCA) and evaluate its metric properties. METHODS: The OMERACT Instrument Selection Algorithm was followed. Forty-nine members of the OMERACT ultrasonography large vessel vasculitis working group were invited to seven Delphi rounds. An online reliability exercise was conducted using images of bilateral common temporal arteries, parietal and frontal branches as well as axillary arteries from 16 patients with GCA and 7 controls. Sensitivity to change and convergent construct validity were tested using data from a prospective cohort of patients with new GCA in which ultrasound-based intima-media thickness (IMT) measurements were conducted at weeks 1, 3, 6, 12 and 24. RESULTS: Agreement was obtained (92.7%) for the OMERACT GCA Ultrasonography Score (OGUS), calculated as follows: sum of IMT measured in every segment divided by the rounded cut-off values of IMTs in each segment. The resulting value is then divided by the number of segments available. Thirty-five members conducted the reliability exercise, the interrater intraclass correlation coefficient (ICC) for the OGUS was 0.72-0.84 and the median intrareader ICC was 0.91. The prospective cohort consisted of 52 patients. Sensitivity to change between baseline and each follow-up visit up to week 24 yielded standardised mean differences from -1.19 to -2.16, corresponding to large and very large magnitudes of change, respectively. OGUS correlated moderately with erythrocyte sedimentation rate, C reactive protein and Birmingham Vasculitis Activity Score (corrcoeff 0.37-0.48). CONCLUSION: We developed a provisional OGUS for potential use in clinical trials.

来源:Ann Rheum Dis,查看原文。版权归原作者所有。

引用

  1. Dejaco C, Ponte C, Monti S, et al. The provisional OMERACT ultrasonography score for giant cell arteritis. Ann Rheum Dis. 2022. PMID: 36600183. doi:10.1136/ard-2022-223367

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。