文献速递痛风与晶体性关节病

放射线摄影诊断焦磷酸钙沉积的可靠性与诊断准确性:国际多学科工作组新定义的表现

Reliability and Diagnostic Accuracy of Radiography for the Diagnosis of Calcium Pyrophosphate Deposition: Performance of the Novel Definitions Developed by an International Multidisciplinary Working Group.
PubMed 文献 · Arthritis Rheumatol · 2023-01-19

研究纳入拟行膝关节置换的膝骨关节炎患者,由2名放射科医生和2名风湿科医生用新放射线定义两次评估焦磷酸钙沉积(CPPD),以术后组织学为参考标准。观察者间信度多数结构为实质性(κ 0.59-0.90),总体特异性92%,但总体敏感性仅54%。新定义高度特异,阳性可确诊CPPD,阴性不能排除诊断。

要点

  • 新放射线定义在多数结构的观察者间信度为实质性(κ 0.59-0.90)。
  • 放射线诊断CPPD总体特异性92%,但总体敏感性低至54%。
  • 阳性放射线表现可确诊CPPD,阴性不能排除诊断。

核心结论

  • 新放射线CPPD定义高度特异,阳性表现可确诊CPPD而非其他含钙晶体沉积,但阴性放射线表现不能排除诊断。

研究设计与样本

  • 纳入拟行膝关节置换的膝骨关节炎患者,由2名放射科医生和2名风湿科医生使用新定义两次评估放射线图像,以术后标本补偿偏振光显微镜组织学检查为参考标准。
  • 信度研究纳入67例患者,准确性研究纳入51例患者。

主要发现

  • 考虑全部4名读者时,多数评估结构的观察者间信度为实质性(κ范围0.59-0.90)。
  • 放射科医生间观察者间信度为实质性至几乎完全一致(κ范围0.70-0.91),风湿科医生间为中等至几乎完全一致(κ范围0.46-0.88)。
  • 所有观察者的观察者内信度为实质性至几乎完全一致(κ范围0.70-1)。
  • 放射线诊断CPPD的总体特异性为92%,但所有部位及总体诊断的敏感性均低(总体54%)。

关键数值与推荐

  • 观察者间信度:全部4名读者κ范围0.59-0.90,放射科医生κ范围0.70-0.91,风湿科医生κ范围0.46-0.88。
  • 观察者内信度:所有观察者κ范围0.70-1。
  • 诊断准确性:总体特异性92%,总体敏感性54%。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To assess the reliability and diagnostic accuracy of new radiographic imaging definitions developed by an international multidisciplinary working group for identification of calcium pyrophosphate deposition (CPPD). METHODS: Patients with knee osteoarthritis scheduled for knee replacement were enrolled. Two radiologists and 2 rheumatologists twice assessed radiographic images for presence or absence of CPPD in menisci, hyaline cartilage, tendons, joint capsule, or synovial membrane, using the new definitions. In case of disagreement, a consensus decision was made and considered for the assessment of diagnostic performance. Histologic examination of postsurgical specimens under compensated polarized light microscopy was the reference standard. Prevalence-adjusted bias-adjusted kappa values were used to assess reliability, and diagnostic performance statistics were calculated. RESULTS: Sixty-seven patients were enrolled for the reliability study. The interobserver reliability was substantial in most of the assessed structures when considering all 4 readers (κ range 0.59-0.90), substantial to almost perfect among radiologists (κ range 0.70-0.91), and moderate to almost perfect among rheumatologists (κ range 0.46-0.88). The intraobserver reliability was substantial to almost perfect for all the observers (κ range 0.70-1). Fifty-one patients were included in the accuracy study. Radiography demonstrated an overall specificity of 92% for CPPD, but sensitivity remained low for all sites and for the overall diagnosis (54%). CONCLUSION: The new radiographic definitions of CPPD are highly specific against the gold standard of histologic diagnosis. When the described radiographic findings are present, these definitions allow for a definitive diagnosis of CPPD, rather than other calcium-containing crystal depositions; however, a negative radiographic finding does not exclude the diagnosis.

来源:Arthritis Rheumatol,查看原文。版权归原作者所有。

引用

  1. Sirotti S, Becce F, Sconfienza LM, et al. Reliability and Diagnostic Accuracy of Radiography for the Diagnosis of Calcium Pyrophosphate Deposition: Performance of the Novel Definitions Developed by an International Multidisciplinary Working Group. Arthritis Rheumatol. 2023. PMID: 36122187. doi:10.1002/art.42368