比较MRI与常规X线摄影在ASAS队列中检测提示中轴型脊柱关节炎的结构改变
在ASAS队列183例疑似中轴型脊柱关节炎(axSpA)患者中,比较骶髂关节MRI与常规X线对结构病变的检测效能。MRI结构病变的敏感度38.5%、特异度91.7%、LR+ 4.62,优于mNY标准X线骶髂关节炎(敏感度54.8%、特异度70.8%、LR+ 1.88)及单侧≥2级阈值(敏感度65.2%、特异度50.0%、LR+ 1.30)。结论为MRI检测的结构病变诊断效能及阅片者间信度优于常规X线。
要点
- MRI结构病变诊断axSpA的敏感度38.5%、特异度91.7%、LR+ 4.62、LR- 0.67。
- mNY标准X线骶髂关节炎敏感度54.8%、特异度70.8%、LR+ 1.88、LR- 0.64。
- X线单侧≥2级骶髂关节炎敏感度65.2%、特异度50.0%、LR+ 1.30、LR- 0.69。
核心结论
- MRI检测的骶髂关节结构病变相比常规X线显示出更好的诊断效能和更好的阅片者间信度。
研究设计与样本
- 纳入ASAS队列中具有提示axSpA症状且骶髂关节MRI和X线片均可行中心判读的成年患者,共183例,其中135例(73.7%)被诊断为axSpA。
- X线片由3名阅片者按modified New York(mNY)标准分级系统评估,MRI由7名阅片者评估提示axSpA的结构改变。
主要发现
- MRI提示axSpA的结构病变:敏感度38.5%、特异度91.7%、PPV 92.9%、NPV 34.6%、LR+ 4.62、LR- 0.67。
- 符合mNY标准的骶髂关节炎:敏感度54.8%、特异度70.8%、PPV 84.1%、NPV 35.8%、LR+ 1.88、LR- 0.64。
- X线单侧至少2级骶髂关节炎:敏感度65.2%、特异度50.0%、PPV 78.6%、NPV 33.8%、LR+ 1.30、LR- 0.69。
关键数值与推荐
- X线结构损伤定义为满足放射学mNY标准,以及额外采用单侧至少2级骶髂关节炎的较低阈值。
- 诊断效能以风湿科医生axSpA诊断为参照计算。
临床怎么用
- 原文未据此给出推荐。
局限性
- 原文未报告局限性。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVES: To compare MRI and conventional radiography of SI joints for detection of structural lesions typical for axial spondyloarthritis (axSpA). METHODS: Adult patients from the Assessment of SpondyloArthritis international Society (ASAS) cohort with symptoms suggestive of axSpA and both SI joint MRI and radiographs available for central reading were included. Radiographs were evaluated by three readers according to the modified New York (mNY) criteria grading system. The presence of structural damage on radiographs was defined as fulfilment of the radiographic mNY criterion and, additionally, a lower threshold for sacroiliitis of at least grade 2 unilaterally. MRI scans were assessed for the presence of structural changes indicative of axSpA by seven readers. Diagnostic performance [sensitivity, specificity, positive and negative predictive values (PPV and NPV) and positive and negative likelihood ratios (LR+ and LR-)] of MRI and radiographs (vs rheumatologist's diagnosis of axSpA) were calculated. RESULTS: Overall, 183 patients were included and 135 (73.7%) were diagnosed with axSpA. Structural lesions indicative of axSpA on MRI had sensitivity 38.5%, specificity 91.7%, PPV 92.9%, NPV 34.6%, LR+ 4.62 and LR- 0.67. Sacroiliitis according to the mNY criteria had sensitivity 54.8%, specificity 70.8%, PPV 84.1%, NPV 35.8%, LR+ 1.88 and LR- 0.64. Radiographic sacroiliitis of at least grade 2 unilaterally had sensitivity 65.2%, specificity 50.0%, PPV 78.6%, NPV 33.8%, LR+ 1.30 and LR- 0.69. CONCLUSION: Structural lesions of the SI joint detected by MRI demonstrated better diagnostic performance and better interreader reliability compared with conventional radiography.
引用
- Protopopov M, Proft F, Wichuk S, et al. Comparing MRI and conventional radiography for the detection of structural changes indicative of axial spondyloarthritis in the ASAS cohort. Rheumatology (Oxford). 2023. PMID: 35951746. doi:10.1093/rheumatology/keac432
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。