文献速递其他结缔组织病

功率多普勒超声在特发性炎症性肌病诊断与监测中的准确性

Accuracy of power Doppler ultrasonography in the diagnosis and monitoring of idiopathic inflammatory myopathies.
PubMed 文献 · Rheumatology (Oxford) · 2023-01-01

研究前瞻性纳入45例特发性炎症性肌病患者,采用功率多普勒超声(PDUS)评估大腿肌肉,并与对照组比较诊断准确性及随访中的变化。结果显示∑PD和∑水肿是诊断特发性炎症性肌病的主要影响因素,随访中∑水肿和∑PD较基线下降,且与医生整体评估的下降相关。

要点

  • ∑PD和∑水肿是诊断特发性炎症性肌病最有力的变量(P=0.017和P=0.013)。
  • ∑PD最佳截断值为0.5,∑水肿为1.5,∑萎缩为0.5,CRP为0.22 mg/dl。
  • 随访中∑水肿和∑PD较基线下降,与医生整体评估下降相关。

核心结论

  • PDUS是鉴别炎症性与非炎症性肌病的可靠诊断工具。
  • PDUS可用于特发性炎症性肌病患者的随访。
  • 疾病活动度(以医生整体评估衡量)下降伴随水肿和PD降低,且与变化率直接相关。

研究设计与样本

  • 前瞻性收集于锡耶纳大学风湿病科血管炎与肌炎门诊评估的所有患者。
  • 纳入45例特发性炎症性肌病患者(中位年龄55岁,四分位距45-66岁;女性35例)及对照组。
  • 所有患者接受双大腿超声检查(轴向和纵向扫描),并重复两次(T1)或三次(T2)。

主要发现

  • 受试者工作特征曲线可基于∑PD、∑水肿、∑萎缩和CRP区分患者与对照组。
  • ∑PD最佳截断值为0.5,∑水肿为1.5,∑萎缩为0.5,CRP为0.22 mg/dl。
  • 逻辑回归分析中,对特发性炎症性肌病诊断影响最大的变量为∑PD(P=0.017)和∑水肿(P=0.013)。
  • ∑水肿在T1(P=0.0108)和T2(P=0.0012)均低于T0。
  • ∑PD在T1(P=0.0294)和T2(P=0.0420)均低于T0。

关键数值与推荐

  • ∑PD最佳截断值0.5,∑水肿最佳截断值1.5,∑萎缩最佳截断值0.5,CRP最佳截断值0.22 mg/dl。
  • 逻辑回归中∑PD的P=0.017,∑水肿的P=0.013。
  • ∑水肿T1 vs T0的P=0.0108,T2 vs T0的P=0.0012。
  • ∑PD T1 vs T0的P=0.0294,T2 vs T0的P=0.0420。
  • 医生整体评估T1 vs 基线的P=0.0349,T2 vs 基线的P=0.0035。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: No clear-cut guidelines exist for the use of imaging procedures for the diagnosis of idiopathic inflammatory myopathies (IIM). The aim of the present study was to assess the diagnostic accuracy of power Doppler ultrasonography (PDUS) score in IIM patients compared with a control group and its usefulness during follow-up. METHODS: All patients evaluated in the Vasculitis and Myositis Clinic, Rheumatology Unit, University of Siena were prospectively collected. All patients underwent US examination of both thighs in axial and longitudinal scans, which were also performed twice (T1) or three times (T2). RESULTS: Forty-five patients with IIM (median [interquartile range] age 55 [45-66] years; 35 female) were enrolled. Receiver operating characteristic curves distinguished patients and controls based on ∑power Doppler (PD), ∑oedema, ∑atrophy and CRP. The best cut-off value for ∑PD was 0.5, ∑oedema 1.5, ∑atrophy 0.5 and CRP 0.22 mg/dl. In a logistic regression analysis, the variables that most influenced diagnosis of IIM were ∑PD and ∑oedema (P = 0.017 and P = 0.013, respectively). ∑Oedema was lower at T1 (P = 0.0108) and T2 (P = 0.0012) than at T0. Likewise, ∑PD was lower at T1 (P = 0.0294) and T2 (P = 0.0420) than at T0. Physician global assessment was lower at T1 (P = 0.0349) and T2 (P = 0.0035) than at baseline. CONCLUSION: Our findings show that PDUS is a reliable diagnostic tool in the differential diagnosis between inflammatory and non-inflammatory myopathies. Moreover, PDUS can be employed also during the follow-up of patients with IIM. A reduction in disease activity, measured by physician global assessment, led to a concomitant decrease in both oedema and PD, which was directly correlated with their rate of change. This underlines the close link between clinical assessment and PDUS findings, not only at diagnosis but also during monitoring.

来源:Rheumatology (Oxford),查看原文。版权归原作者所有。

引用

  1. Conticini E, Falsetti P, Grazzini S, et al. Accuracy of power Doppler ultrasonography in the diagnosis and monitoring of idiopathic inflammatory myopathies. Rheumatology (Oxford). 2023. PMID: 35731121. doi:10.1093/rheumatology/keac351

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。