低剂量CT亨氏单位:评估放射学中轴型脊柱关节炎椎体骨密度的可靠方法
该横断面研究纳入50例放射学中轴型脊柱关节炎患者的多中心2年前瞻性队列低剂量CT扫描,由两名经过培训的阅片者独立测量C3-L5各椎体中心松质骨亨氏单位(HU)。结果显示HU值从颅侧向尾侧递减,阅片者间信度优秀(ICC(2,1) 0.89至1.00),结论认为低剂量CT测量HU是评估椎体骨密度的可行方法,但需进一步验证和纵向评估信度。
要点
- 低剂量CT测量椎体松质骨HU在放射学中轴型脊柱关节炎中可行,阅片者间信度优秀(ICC(2,1) 0.89至1.00)。
- HU值从颅侧向尾侧递减,C3最高(阅片者1为354(106),阅片者2为355(108)),L3最低(阅片者1为153(65),阅片者2为150(65))。
- 最小可检测差异为4至8,Bland-Altman图显示同方差性。
核心结论
- 低剂量CT测量HU是评估放射学中轴型脊柱关节炎椎体骨密度的可行方法,C3至L5阅片者间信度优秀,但结果需进一步验证和纵向评估信度。
研究设计与样本
- 横断面分析,纳入敏感影像学在强直性脊柱炎研究这一多中心2年前瞻性队列中50例放射学中轴型脊柱关节炎患者的低剂量CT扫描。
- 由两名经过培训的阅片者独立评估C3-L5各椎体中心感兴趣区的松质骨HU。
- 采用组内相关系数(ICC;单次测量、绝对一致性、双向混合效应模型)、最小可检测差异和Bland-Altman图评估阅片者间信度和一致性。
主要发现
- 每位阅片者共评估1100个椎体,HU值从颅侧向尾侧递减。
- 阅片者1和阅片者2的最高平均(SD)HU值均位于C3,分别为354(106)和355(108);最低均位于L3,分别为153(65)和150(65)。
- 阅片者间信度优秀(ICC(2,1):0.89至1.00),最小可检测差异为4至8。
- 大多数椎体阅片者1的评分略高于阅片者2(平均评分差异范围为-0.6至2.9 HU),Bland-Altman图显示同方差性。
局限性
- 原文结论指出这些结果需进一步验证和纵向评估信度。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: Studying vertebral bone loss in radiographic axial spondyloarthritis (r-axSpA) has been challenging due to ectopic bone formation. We cross-sectionally analysed low-dose CT (ldCT) trabecular bone density Hounsfield units (HU) measurements and calculated inter-reader reliability at the vertebral level in patients with r-axSpA. METHODS: LdCT scans of 50 patients with r-axSpA from the sensitive imaging in ankylosing spondylitis study, a multicentre 2-year prospective cohort were included. Trabecular bone HU taken from a region of interest at the centre of each vertebra (C3-L5) were independently assessed by two trained readers. HU mean (SD), and range were provided at the vertebral level, for each reader and centre separately. Inter-reader reliability and agreement were assessed using intraclass correlation coefficients (ICC; single measurements, absolute agreement, two-way mixed effects models); smallest detectable difference and Bland-Altman plots. RESULTS: Overall, 1100 vertebrae were assessed by each reader. HU values decreased from cranial to caudal vertebrae. For readers 1 and 2 respectively, the highest mean (SD) HU value was obtained at C3 (354(106) and 355(108)), and the lowest at L3 (153(65) and 150 (65)). Inter-reader reliability was excellent (ICC(2,1):0.89 to 1.00). SDD varied from 4 to 8. For most vertebrae, reader 1 scored somewhat higher than reader 2 (mean difference of scores ranging from -0.6 to 2.9 HU). Bland-Altman plots showed homoscedasticity. CONCLUSION: LdCT measurement of HU is a feasible method to assess vertebral bone density in r-axSpA with excellent inter-reader reliability from C3 to L5. These results warrant further validation and longitudinal assessment of reliability.
引用
- Marques ML, Pereira da Silva N, van der Heijde D, et al. Low-dose CT hounsfield units: a reliable methodology for assessing vertebral bone density in radiographic axial spondyloarthritis. RMD Open. 2022. PMID: 35732346. doi:10.1136/rmdopen-2021-002149
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。