文献速递其他结缔组织病

原发性干燥综合征中唾液腺超声与唾液腺闪烁显像的相关性

Correlation between salivary gland ultrasonography and scintigraphy in primary Sjögren's syndrome.
PubMed 文献 · Rheumatology (Oxford) · 2022-01-01

研究纳入36例新诊断原发性干燥综合征患者,其中唾液腺超声阳性(SGUS评分≥14)与阴性各18例,比较唾液腺超声与闪烁显像结果。SGUS阳性组腮腺摄取、腮腺排泄百分比、颌下腺摄取及颌下腺排泄百分比均显著低于SGUS阴性组。腮腺SGUS评分与腮腺摄取及腮腺排泄百分比呈负相关,颌下腺SGUS评分与颌下腺摄取及颌下腺排泄百分比呈负相关。

要点

  • SGUS评分≥14定义为阳性,SGUS阳性组腮腺和颌下腺摄取及排泄功能均低于阴性组。
  • 腮腺SGUS评分与腮腺摄取(r=-0.36,P=0.03)及腮腺排泄百分比(r=-0.35,P=0.04)负相关。
  • 颌下腺SGUS评分与颌下腺摄取(r=-0.42,P=0.01)及颌下腺排泄百分比(r=-0.39,P=0.02)负相关。

核心结论

  • SGUS评分较高的患者唾液腺功能较低,SGUS评分与腮腺摄取、腮腺排泄百分比、颌下腺摄取及颌下腺排泄百分比均呈显著相关,这些发现提示SGUS可能具有诊断唾液腺功能障碍的预测作用。

研究设计与样本

  • 研究队列纳入在同一三级医院同时接受唾液腺超声和唾液腺闪烁显像的新诊断原发性干燥综合征患者,收集基线人口学、实验室、临床及两种检查结果。
  • 以SGUS评分≥14定义阳性,将患者分为SGUS阳性组和SGUS阴性组,最终每组各18例、共36例纳入分析。

主要发现

  • SGUS阳性组与SGUS阴性组在基线人口学、临床及实验室数据方面均无组间差异。
  • SGUS阳性组腮腺摄取、腮腺排泄百分比、颌下腺摄取及颌下腺排泄百分比均显著低于SGUS阴性组。
  • 腮腺SGUS评分与腮腺摄取呈负相关(r=-0.36,P=0.03),与腮腺排泄百分比呈负相关(r=-0.35,P=0.04)。
  • 颌下腺SGUS评分与颌下腺摄取呈负相关(r=-0.42,P=0.01),与颌下腺排泄百分比呈负相关(r=-0.39,P=0.02)。

关键数值与推荐

  • SGUS评分≥14定义为唾液腺超声阳性。
  • 闪烁显像以腮腺与颌下腺摄取比(PU:SU)及腮腺/颌下腺排泄百分比(%PE/%SE)量化。

临床怎么用

  • 原文未据此给出推荐。

局限性

  • 原文未报告局限性。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVE: To compare findings on salivary gland ultrasonography (SGUS) and salivary gland scintigraphy (SGS) in patients with primary SS (pSS). METHODS: The study cohort included patients newly diagnosed with pSS who underwent SGUS and SGS at the same time at our tertiary care hospital. Baseline demographics, laboratory data, clinical data and SGUS and SGS findings were collected. An SGUS cut-off score ≥14 defined positive SGUS findings and was used to classify patients in SGUS+ and SGUS- groups. SGS findings were quantified by the parotid:submandibular uptake ratio (PU:SU) and percentage parotid/submandibular excretion (%PE/%SE). The correlation between SGUS and SGS findings was evaluated. RESULTS: For analysis, 18 patients with SGUS+ findings and 18 with SGUS- findings were recruited, for a total study cohort of 36 patients. There were no between-group differences in baseline demographics and clinical and laboratory data. The PU, %PE, SU and %SE were significantly lower in the SGUS+vs SGUS- group. The SGUS score for the parotid gland was negatively correlated to the PU (r = -0.36, P = 0.03) and %PE (r = -0.35, P = 0.04). The SGUS score of the submandibular gland was negatively correlated to the SU (r = -0.42, P = 0.01) and %SE (r = -0.39, P = 0.02). CONCLUSIONS: Patients with a higher SGUS score had lower salivary gland function. The SGUS score showed a significant correlation with PU, %PE, SU and %SE. These findings are indicative of a possible predictive role of SGUS to diagnose salivary gland dysfunction.

来源:Rheumatology (Oxford),查看原文。版权归原作者所有。

引用

  1. Min HK, Kim SH, Lee KA, et al. Correlation between salivary gland ultrasonography and scintigraphy in primary Sjögren's syndrome. Rheumatology (Oxford). 2022. PMID: 34888620. doi:10.1093/rheumatology/keab881

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。