文献速递流行病学与生物统计临床试验与 GCP

成人高血压诊断:诊室与家庭血压测量的准确性系统综述

Does This Adult Patient Have Hypertension?: The Rational Clinical Examination Systematic Review.
PubMed 文献 · JAMA · 2021-01-01

该系统综述纳入比较示波法诊室血压与家庭血压监测(HBPM)以24小时动态血压监测(ABPM)为参考标准诊断成人高血压准确性的研究。诊室血压≥140/90 mm Hg的灵敏度51%、特异度88%,HBPM≥135/85 mm Hg的灵敏度75%、特异度76%。诊室血压可能不足以确诊或排除高血压,HBPM有助于确认诊断,当阈值不确定或诊室与HBPM不一致时应考虑24小时ABPM。

要点

  • 诊室示波法血压≥140/90 mm Hg诊断高血压灵敏度仅51%,特异度88%。
  • 家庭血压监测≥135/85 mm Hg灵敏度75%、特异度76%,有助于确认诊断。
  • 诊室与家庭血压不一致或阈值不确定时,应考虑24小时动态血压监测。

核心结论

  • 诊室血压测量可能不够准确,不足以确诊或排除高血压。
  • 家庭血压监测可能有助于确认高血压诊断。
  • 当阈值不确定或诊室与家庭血压不一致时,应考虑24小时动态血压监测以确立诊断。

研究设计与样本

  • 系统综述检索PubMed、Cochrane Library、Embase、ClinicalTrials.gov、DARE数据库及美国心脏协会网站,截至2021年4月。
  • 纳入12项横断面研究(n=6877)比较诊室示波法血压与24小时ABPM平均血压。
  • 纳入6项研究(n=2049)比较家庭血压监测平均血压与24小时ABPM平均血压。
  • 两项作者独立提取原始数据并评估方法学质量,第三位作者解决分歧。
  • 采用随机效应模型计算汇总灵敏度、特异度和似然比。

主要发现

  • 诊室血压测量评估研究中,24小时ABPM定义的高血压总体患病率为49%(95%CI,39%-60%)。
  • 家庭血压监测评估研究中,24小时ABPM定义的高血压总体患病率为54%(95%CI,39%-69%)。
  • 诊室示波法血压≥140/90 mm Hg(单次就诊1-5次测量)灵敏度51%(95%CI,36%-67%),特异度88%(95%CI,80%-96%),阳性似然比4.2(95%CI,2.5-6.0),阴性似然比0.56(95%CI,0.42-0.69)。
  • 家庭血压监测平均血压≥135/85 mm Hg灵敏度75%(95%CI,65%-86%),特异度76%(95%CI,65%-86%),阳性似然比3.1(95%CI,2.2-4.0),阴性似然比0.33(95%CI,0.20-0.47)。
  • 两项研究比较无人值守自动诊室平均血压(≥135/85 mm Hg)与24小时ABPM,灵敏度范围48%至51%,特异度范围80%至91%。

关键数值与推荐

  • 参考标准为24小时ABPM:24小时平均血压≥130/80 mm Hg或清醒时平均血压≥135/85 mm Hg。
  • 诊室血压诊断阈值为140/90 mm Hg,家庭血压监测诊断阈值为135/85 mm Hg。
  • 一项研究比较有人值守自动诊室平均血压(≥140/90 mm Hg)与24小时ABPM,灵敏度87.6%(95%CI,83%-92%),特异度24.1%(95%CI,16%-32%)。

临床怎么用

  • 诊室血压测量不足以单独确诊或排除高血压,应结合诊室外血压测量。
  • 家庭血压监测可用于确认高血压诊断,尤其当诊室血压处于阈值附近时。
  • 当诊室与家庭血压不一致或阈值不确定时,应使用24小时动态血压监测确立诊断。

局限性

  • 纳入研究多为非连续样本,仅2项研究(n=3040)使用连续样本。
  • 各分析纳入研究间样本量差异较大(每项分析117至2209例参与者)。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

IMPORTANCE: Office blood pressure (BP) measurements are not the most accurate method to diagnose hypertension. Home BP monitoring (HBPM) and 24-hour ambulatory BP monitoring (ABPM) are out-of-office alternatives, and ABPM is considered the reference standard for BP assessment. OBJECTIVE: To systematically review the accuracy of oscillometric office and home BP measurement methods for correctly classifying adults as having hypertension, defined using ABPM. DATA SOURCES: PubMed, Cochrane Library, Embase, ClinicalTrials.gov, and DARE databases and the American Heart Association website (from inception to April 2021) were searched, along with reference lists from retrieved articles. DATA EXTRACTION AND SYNTHESIS: Two authors independently abstracted raw data and assessed methodological quality. A third author resolved disputes as needed. MAIN OUTCOMES AND MEASURES: Random effects summary sensitivity, specificity, and likelihood ratios (LRs) were calculated for BP measurement methods for the diagnosis of hypertension. ABPM (24-hour mean BP ≥130/80 mm Hg or mean BP while awake ≥135/85 mm Hg) was considered the reference standard. RESULTS: A total of 12 cross-sectional studies (n = 6877) that compared conventional oscillometric office BP measurements to mean BP during 24-hour ABPM and 6 studies (n = 2049) that compared mean BP on HBPM to mean BP during 24-hour ABPM were included (range, 117-2209 participants per analysis); 2 of these studies (n = 3040) used consecutive samples. The overall prevalence of hypertension identified by 24-hour ABPM was 49% (95% CI, 39%-60%) in the pooled studies that evaluated office measures and 54% (95% CI, 39%-69%) in studies that evaluated HBPM. All included studies assessed sensitivity and specificity at the office BP threshold of 140/90 mm Hg and the home BP threshold of 135/85 mm Hg. Conventional office oscillometric measurement (1-5 measurements in a single visit with BP ≥140/90 mm Hg) had a sensitivity of 51% (95% CI, 36%-67%), specificity of 88% (95% CI, 80%-96%), positive LR of 4.2 (95% CI, 2.5-6.0), and negative LR of 0.56 (95% CI, 0.42-0.69). Mean BP with HBPM (with BP ≥135/85 mm Hg) had a sensitivity of 75% (95% CI, 65%-86%), specificity of 76% (95% CI, 65%-86%), positive LR of 3.1 (95% CI, 2.2-4.0), and negative LR of 0.33 (95% CI, 0.20-0.47). Two studies (1 with a consecutive sample) that compared unattended automated mean office BP (with BP ≥135/85 mm Hg) with 24-hour ABPM had sensitivity ranging from 48% to 51% and specificity ranging from 80% to 91%. One study that compared attended automated mean office BP (with BP ≥140/90 mm Hg) with 24-hour ABPM had a sensitivity of 87.6% (95% CI, 83%-92%) and specificity of 24.1% (95% CI, 16%-32%). CONCLUSIONS AND RELEVANCE: Office measurements of BP may not be accurate enough to rule in or rule out hypertension; HBPM may be helpful to confirm a diagnosis. When there is uncertainty around threshold values or when office and HBPM are not in agreement, 24-hour ABPM should be considered to establish the diagnosis.

来源:JAMA,查看原文。版权归原作者所有。

引用

  1. Viera AJ, Yano Y, Lin FC, et al. Does This Adult Patient Have Hypertension?: The Rational Clinical Examination Systematic Review. JAMA. 2021. PMID: 34313682. doi:10.1001/jama.2021.4533

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。