医院焦虑抑郁量表抑郁亚量表(HADS-D)筛查重性抑郁的准确性:系统综述与个体参与者数据荟萃分析
结果显示HADS-D cutoff≥7时合并敏感度与特异度最大化,不同参考标准及亚组间准确性相似。
要点
- HADS-D cutoff≥7在半结构化访谈研究中敏感度0.82、特异度0.78。
- cutoff≥8敏感度0.74、特异度0.84,与cutoff≥7合并准确度相似但更特异。
- 临床可据目的调整cutoff:降低cutoff避免漏诊,提高cutoff减少误诊。
核心结论
- 在躯体疾病患者中筛查重性抑郁时,HADS-D cutoff≥7使合并敏感度与特异度最大化。
研究设计与样本
- 系统综述与个体参与者数据荟萃分析,检索Medline、PsycInfo和Web of Science至2018年10月25日。
主要发现
- 同组研究中cutoff≥8敏感度0.74(0.68–0.79)、特异度0.84(0.81–0.87);cutoff≥11敏感度0.44(0.38–0.51)、特异度0.95(0.93–0.96)。
关键数值与推荐
- 推荐HADS-D cutoff≥7用于筛查重性抑郁,以兼顾敏感度与特异度。
- cutoff≥8合并准确度与cutoff≥7相似,但敏感度更低、特异度更高。
临床怎么用
- 筛查躯体疾病患者抑郁时,可用较低cutoff避免假阴性,较高cutoff减少假阳性并识别症状较重者。
局限性
- 仅60%合格研究提供个体数据,但敏感性分析显示纳入未提供原始数据的已发表结果对结论影响不大。
以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。
原文
OBJECTIVE: To evaluate the accuracy of the depression subscale of the Hospital Anxiety and Depression Scale (HADS-D) to screen for major depression among people with physical health problems. DESIGN: Systematic review and individual participant data meta-analysis. DATA SOURCES: Medline, Medline In-Process and Other Non-Indexed Citations, PsycInfo, and Web of Science (from inception to 25 October 2018). REVIEW METHODS: Eligible datasets included HADS-D scores and major depression status based on a validated diagnostic interview. Primary study data and study level data extracted from primary reports were combined. For HADS-D cut-off thresholds of 5-15, a bivariate random effects meta-analysis was used to estimate pooled sensitivity and specificity, separately, in studies that used semi-structured diagnostic interviews (eg, Structured Clinical Interview for Diagnostic and Statistical Manual of Mental Disorders), fully structured interviews (eg, Composite International Diagnostic Interview), and the Mini International Neuropsychiatric Interview. One stage meta-regression was used to examine whether accuracy was associated with reference standard categories and the characteristics of participants. Sensitivity analyses were done to assess whether including published results from studies that did not provide raw data influenced the results. RESULTS: Individual participant data were obtained from 101 of 168 eligible studies (60%; 25 574 participants (72% of eligible participants), 2549 with major depression). Combined sensitivity and specificity was maximised at a cut-off value of seven or higher for semi-structured interviews, fully structured interviews, and the Mini International Neuropsychiatric Interview. Among studies with a semi-structured interview (57 studies, 10 664 participants, 1048 with major depression), sensitivity and specificity were 0.82 (95% confidence interval 0.76 to 0.87) and 0.78 (0.74 to 0.81) for a cut-off value of seven or higher, 0.74 (0.68 to 0.79) and 0.84 (0.81 to 0.87) for a cut-off value of eight or higher, and 0.44 (0.38 to 0.51) and 0.95 (0.93 to 0.96) for a cut-off value of 11 or higher. Accuracy was similar across reference standards and subgroups and when published results from studies that did not contribute data were included. CONCLUSIONS: When screening for major depression, a HADS-D cut-off value of seven or higher maximised combined sensitivity and specificity. A cut-off value of eight or higher generated similar combined sensitivity and specificity but was less sensitive and more specific. To identify medically ill patients with depression with the HADS-D, lower cut-off values could be used to avoid false negatives and higher cut-off values to reduce false positives and identify people with higher symptom levels. TRIAL REGISTRATION: PROSPERO CRD42015016761.
引用
- Wu Y, Levis B, Sun Y, et al. Accuracy of the Hospital Anxiety and Depression Scale Depression subscale (HADS-D) to screen for major depression: systematic review and individual participant data meta-analysis. BMJ. 2021. PMID: 33972268. doi:10.1136/bmj.n972
供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。