文献速递流行病学与生物统计

新指标改善诊断准确性试验准确性综述异质性报告:一项元流行病学研究

New measures improved the reporting of heterogeneity in diagnostic test accuracy reviews: a metaepidemiological study.
PubMed 文献 · J Clin Epidemiol · 2020-11-21

该元流行病学研究纳入Cochrane图书馆截至2019年10月6日的全部124篇诊断准确性试验(DTA)综述,其中91篇(73%)含meta分析。研究描述异质性量化方法,并选择60篇使用双变量模型且纳入≥4项研究的综述重新分析,提出中位比值比(OR)和95%预测椭圆面积等替代指标以改善异质性报告。

要点

  • Cochrane DTA综述对异质性报告不足,仅5篇meta分析报告了logit灵敏度与特异度方差。
  • 多数综述主观描述异质性为中度或极端(31/60,52%),但客观指标显示高变异性。
  • 中位OR和95%预测椭圆面积可改善DTA meta分析异质性的报告与解读。

核心结论

  • Cochrane DTA综述对研究间异质性报告较差。
  • 使用中位OR和95%预测椭圆面积可改善DTA meta分析异质性的报告与解读。

研究设计与样本

  • 元流行病学研究纳入Cochrane图书馆截至2019年10月6日的全部124篇DTA综述。
  • 91篇(73%)含meta分析,其中60篇使用双变量模型且纳入≥4项研究被选入重新分析。
  • 重新分析拟合双变量随机效应模型,量化logit灵敏度与特异度方差、双变量I2、中位OR和95%预测椭圆面积。

主要发现

  • 仅5篇meta分析报告了logit灵敏度与特异度方差,21篇(23%)报告了95%预测椭圆但未计算其面积。
  • 60篇重新分析中,31篇(52%)主观描述异质性为中度或极端。
  • 95%预测椭圆面积范围为5%至97%,灵敏度中位OR范围为1.13至10.7,特异度中位OR范围为1.18至19.68。

关键数值与推荐

  • 推荐使用中位OR和95%预测椭圆面积来量化和报告DTA meta分析中的异质性。

临床怎么用

  • 在DTA综述中应常规计算并报告灵敏度与特异度的中位OR及95%预测椭圆面积。
  • 结合客观异质性指标而非仅主观描述来解读DTA meta分析结果。

以上解读依据论文摘要(全文未开放获取或许可不允许翻译转载)。

原文

OBJECTIVES: To describe the methods used to quantify heterogeneity and to propose alternative measures to improve reporting of heterogeneity in Cochrane diagnostic test accuracy (DTA) reviews. STUDY DESIGN AND SETTING: Our metaepidemiological study included all DTA reviews in the Cochrane Library up to October 6th, 2019. We summarized reviews' characteristics focusing on heterogeneity analysis. We selected reviews with a bivariate model and ≥4 studies for reanalysis. In this group, we fitted bivariate random effects models and we quantified heterogeneity by means of logit variances of sensitivity and specificity, bivariate I2, median odds ratio (OR), and the area of the 95% prediction ellipse. We provided a narrative interpretation of these measures in different scenarios. RESULTS: There were 124 Cochrane DTA reviews of which 91 (73%) included meta-analysis. Only in 5 meta-analyses, variances of the logit sensitivity and specificity were reported, and in 21 meta-analyses (23%), the 95% prediction ellipse was reported without any calculation of its area. We selected 60 of these 91 reviews to explore the behavior of all measures of heterogeneity. We found that most reviews described the subjective heterogeneity as moderate or extreme (n = 31/60, 52%), whereas the area of the 95% prediction ellipse and the median OR for sensitivity and specificity showed high variability; the area ranged from 5% to 97%, the median OR of sensitivity ranged from 1.13 to 10.7, and the median OROR of specificity ranged from 1.18 to 19.68. CONCLUSION: Cochrane DTA reviews show a poor reporting of between-study heterogeneity. Using median OR and the area of the 95% prediction ellipse will improve reporting and interpretation of this crucial aspect of DTA meta-analysis.

来源:J Clin Epidemiol,查看原文。版权归原作者所有。

引用

  1. Plana MN, Pérez T, Zamora J, et al. New measures improved the reporting of heterogeneity in diagnostic test accuracy reviews: a metaepidemiological study. J Clin Epidemiol. 2020. PMID: 33227449. doi:10.1016/j.jclinepi.2020.11.011

供执业医师工作参考,不替代临床判断;数值与分级以指南原文为准。